| 1 | Hiring Structural Consultant:The scope includes the structural design, detailing, and drawings for a Mild Steel (MS) roof shed to cover the DG sets and transformers installed in the RRS Building premises. The shed shall be designed to protect equipment from rain, wind, sun exposure, and corrosion while ensuring adequate ventilation and accessibility for maintenance Deliverables from Structural Consultant required are GA drawings & detailed fabrication drawings,Structural design calculations,Load calculation sheets,Foundation drawings, stability certification after erection |
| 2 | Providing and fixing precoated galvanised iron profile sheets (size, shape and corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, of total complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 3 | Ridges plain (500 - 600mm) |
| 4 | structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete two coat of enamal Paint . |
| 5 | Supplying, drilling / cleaning hole and fixing of chemical anchor fastners of 16mm dia embedded upto 150 mm in concrete for fixing of base plate as per the directions of Engineeer Incharge including all the required preparing surface by demolishing water proofing, RCC surface if any . |
| 6 | PCC M10Providing and laying in position ready mixed or site batched design mixcementconcrete for plain cement concrete work; using coarse aggregateand fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommendedproportions as per IS: 9103 to accelerate / retard setting of concrete, toimprove durability and workability without impairing strength; includingpumping of concrete to site of laying, curing, carriage for all leads; butexcluding the cost of centering, shuttering and finishing as per directionof the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the minimum specified cementcontent, the contractor shall have discretion to either re-design the mixor bear the cost of extra cement. |
| 7 | ACP :Providing, fabricating and supplying and fixing panels of aluminiumcomposite panel cladding in pan shape in metalic colour of approvedshades made out of 4 mm thick aluminium composite panel materialconsisting of 3 mm thick FR grade mineral core sandwiched betweentwo Aluminium sheets (each 0.5 mm thick). The aluminium compositepanel cladding sheet shall be coil coated, with Kynar 500 based PVDF /Lumiflon based fluoropolymer resin coating of approved colour and shadeon face # 1 and polymer (Service) coating on face # 2 as specified usingstainless steel screws, nuts, bolts, washers, cleats, weather siliconesealant, backer rods etc. |
| 8 | Vinayal sickring for signage Vinyl Stickering for Signage for signage:Supply and installation of premium self-adhesive polymeric vinyl graphics, minimum 70 micron thick with permanent solvent acrylic pressure-sensitive adhesive, digitally printed using eco-solvent/UV inks at minimum 720 dpi resolution, including UV-protective cold lamination, complete with surface preparation, alignment, trimming, and application on approved substrates as per drawings and manufacturer recommendationsetc. complete, all as per direction of Engineer-in-charge. |
| 9 | Alluminium framing :Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge. |
| 10 | Heavy eavy duty chamber cover:Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8graded stone aggregate 40 mm nominal size), inside plastering 12 mmthick with cement mortar 1:3 (1 cement : 3 coarse sand) finished withfloating coat of neat cement and making channels in cement concrete1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) finished with a floating coat of neat cement complete as perstandard design :Inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty) 455x610 mm internaldimensions, total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight offrame 15 kg) :With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 11 | PVC Gutter 300x300Providing, laying, jointing, fitting, testing heavy quality P.V.C. pipes of Prince, Supreme etc. make & of required dia including all fittings required as per site requirement & laying the same at any floor levels including scaffolding all jointing materials & clamping in wooden blocks if required etc. complete as directed & specified by Engineer-In-Charge. |
| 12 | 110mmProviding, laying, jointing, fitting, testing heavy quality P.V.C. pipes of Prince, Supreme etc. make & of required dia including all fittings required as per site requirement & laying the same at any floor levels including scaffolding all jointing materials & clamping in wooden blocks if required etc. complete as directed & specified by Engineer-In-Charge. Please Enable Macros to View BoQ information |