| 1 | General Notes:1. Contractor shall inspect the site to acquaint with the site conditions as well as security conditions at AMD.2. The rates quoted shall include cost of all tools and tackles, manpower including wages, liveries, all wastages and taxes GST, Labour cess, IT, etc., as applicable but exclusive of EPF and ESI .EPF and ESI are reimbursable as per relevant clause. |
| 2 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt etc. complete as per direction of E-I-C |
| 3 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) complete as per Direction of E-I-C |
| 4 | supply and Laying of one number XLPE power cable of 1.1 KV grade of 4 core 25sqmm alluminum cable direct in ground of 0.7 meter including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering etc. complete as per direction of E-I-C |
| 5 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required as per direction of E-I-C |
| 6 | Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 25 sq. mm (28mm)of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required etc. complete as per direction of E-I-C |
| 7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 8 | supply and fixing of pole mounted FRP box dimension of 250 X 250 X 155 mm With 32A ,4 way terminal strip and din bar for MCB mounting etc as required (excluding MCB) complete as per direction of engineering incharge . |
| 9 | Design ,fabricating supply and fixing of control panel of outdoor type of 14 SWG CRCA Sheet steel ,powder coated dust and vermium proof with suitable bus bar arrangements front operating doors and covers floor mounting arrangement made up with 30mmx30mmx4mm ‘L” angle iron painted with Siemens grey or of approved colour and all internal wiring for power and control circuit complete as per specifications including and fixing of switch gear and metering equipments and accessories etc complete as requiredBrief details of componentsA. 100A ,10KA TPN MCCB -1NOB. 63A , 10KA TPN MCB- 1 NoC. 32A ,10KA TPN MCB- 1 NoD. 32A ,10KA DP MCB- 2 NoE. 100A TPN Aluminum bus bar with supports-01 setF. RYB indicating lamps-01 setG. 100/5 amps digital ammeter-01 NoH. 0-500 volts digital voltmeter-01 NoI. 100/5 amps class-1, 5VA,cts -01 set/3 NosJ. 63 amps 3 pole contactor with 230 volts coil-01 NoK. Analog 24 hr timer switch -01 NoL. Incoming and outgoing terminals-01 set etc. complete as per direction of E-I-C |
| 10 | supplying and fixing of 4\\"x 4\\" FRP junction box with door with 4 way terminal strip with all necessary acceseries etc complete as required as per direction of E-I-C |
| 11 | Cutting road and making good the same including supply of extraquantities of materials i.e. aggregate, moorum screening, red bajri and labour required as per Direction of E-I-C |
| 12 | Supplying and drawing 2x1.5 sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.etc. complete as per direction of E-I-C. Please Enable Macros to View BoQ information |