| 1 | SCHEDULE 'A' PART-I: E/M WORKS |
| 2 | Supply lay and testing of cable in trenches/walls/ floor XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 25sqmm 4.0 core complete incl taking down all as specified and directed by Engr-in-charge. |
| 3 | Supply lay and testing of cable in trenches/walls/floor XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 10sqmm 4.0 core complete incl taking down all as specified and directed by Engr-in-charge. |
| 4 | Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified |
| 6 | Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified. |
| 7 | M&L heavy duty DWC pipe 40mm dia for cable/wire protection duly laid in floors complete all as specified and as directed |
| 8 | Supply and fixing in replacement of Factory made sheet metal enclosure for VTPN MCCB DBs double door (Fixed flush to the wall), with provision of MCCB as incommer & outgoing as TPN 415 volt, 8 Way, with suitable rated bus bar suitable for having MCB’s , complete all as specified (Note : MCCB/MCBs will be measured and paid separately under relavent items ) |
| 9 | Supply and fixing in replacement of Factory made sheet metal enclosure for VTPN MCCB DBs double door (Fixed flush to the wall), with provision of MCCB as incommer & outgoing as TPN 415 volt, 4 Way, Isuitable rated bus bar and suitable for having MCB’s , complete all as specified. (Note : MCCB/MCBs will be measured and paid separately under relavent items ) |
| 10 | Supply and fixing in replacement of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt, 4 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified. (Note : MCBs will be measured and paid separately under relavent items ) |
| 11 | Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 8 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified. (Note : MCBs will be measured and paid separately under relavent items ) |
| 12 | Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 12 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified. (Note : MCBs will be measured and paid separately under relavent items ) |
| 13 | Supply and fixing in repair of Factory made sheet metal enclosure for DBs (Fixed flush to the wall), SPN, 240 volt, 4 Way, suitable rated bus bar and suitable for having MCB’s , complete all as specified. (Note : MCBs will be measured and paid separately under relavent items ) |
| 14 | Supply and fixing of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified |
| 15 | Supply and fixing of MCB 40-100 Amp, 415 Volt, TPN, breaking capacity 10 KA 'C' series, , complete all as specified |
| 16 | Supply and fixing of MCB 6 to 32Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, , complete all as specified |
| 17 | Supply and fixing of MCB 63 Amp, 415 Volt, TP, breaking capacity 10 KA 'C' series, , complete all as specified |
| 18 | M&L for sub main wiring with four run of 10.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 10.0 Sq mm drawn through PVC concealed/surface conduict of 40 mm dia, including taking down unsv sub main wiring of any type, complete all as specified.Note: Copper conductor 05 run along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate. |
| 19 | M&L for sub main wiring with two run of 10.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 10.0 Sq mm drawn through PVC concealed/surface conduict of 40 mm dia, including taking down unsv sub main wiring of any type, complete all as specified.Note: Copper conductor 03 run along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate. |
| 20 | M&L for sub main wiring with two run of 6.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 6.0Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate. |
| 21 | M&L for sub main wiring with two run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0 Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate. |
| 22 | M&L for sub main wiring with two run of 2.5 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 2.5 Sq mm drawn through PVC concealed/surface conduict of 25 mm dia, including taking down unsv sub main wiring of any type, complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate. |
| 23 | S&F circuit / submain wiring alongwith earth wire for PVC insulated copper conductor single core in surface/ recessed multistranded with FRLSH wiring in exisiting conduit (any type) of size 1.5 sqmm with 3 runs incl taking down the existing complete all as specified and as directed |
| 24 | S&F circuit / submain wiring alongwith earth wire for PVC insulated copper conductor single core in surface/ recessed multistranded with FRLSH wiring in PVC Conduit of size 1.5 sqmm with 3 runs incl taking down the existing complete all as specified and as directed Please Enable Macros to View BoQ information |
| 25 | S&F circuit / submain wiring alongwith earth wire for PVC insulated copper conductor single core in surface/ recessed multistranded with FRLSH wiring in PVC Conduit of size 1.5 sqmm with 3 runs incl taking down the existing complete all as specified and as directed Please Enable Macros to View BoQ information |