| Sl. No. | Item Description |
| 1 | M&L Servicing of indoor unit of split type AC of 1.0/1.5/2.0/3.0 Ton Capacity of any make by air blowing, cleaning the filter in water and drying in sun, cleaning of drain tray and rectifying water leak, checking and tightening the electrical connection all as specified and as directed. |
| 2 | M & L for servicing of outdoor unit of Split type air conditioner of 1.0/1.5/2.0/3.0 Ton capacity any make by compressed air and water washing, descaling of condenser coil and oiling of outdoor fan motor, checking and tightening of all the electrical connections, nuts, bolts, washers all as specified and as directed. |
| 3 | M & L for painting of outdoor unit of Split type air conditioner of 1.5/2.0/3.0 ton capacity any make including preparation of old painted surface complete and painting with one coat of Synthetic enamel paint complete in position all as specified and as directed. |
| 4 | M& L for stickering of MES/SM Nos on indoor and outdoor unit of any type of air conditioning in any location all as specified and as directed. |
| 5 | M& L for Removing the Split type AC 1.0 ton to 2.0 Ton, by taking out from the existing position after pumping down gas from position with frame, outdoor / indoor unit carefully, shifting to new position, cutting opening wall of required size & fix in new position, topping up of gas and making good disturbed surface of wall opening by plastering and appling white wash including closing the old opening making good disturbed surface plastering and appling white wash all as specified and as directed. |
| 6 | M& L for Removing the Split type/ tower / cassette type AC 3.0 ton to 4.0 ton capacity after pumping down gas from position, refixing to new position along with and charging of gas in the compressor after rectifying leak and rat cutting complete all as directed. |
| 7 | Supply and charge of gas R-410/R32 for inverter type split AC of 1.0/1.5/2.0/3.0/4.0 Ton capacity after leak testing and rectification of leak all as specified & directed. |
| 8 | Supply and charge of gas R22/R134a to Split AC,Tower AC, Cassette Type AC of 1.0/1.5/2.0/3.0/4.0 Ton capacity after leak testing and rectification of leak all as specified & directed. |
| 9 | M&L for taking out old unserviceable capillary and strainer from refrigerator and supply and fix new capillary & strainer of any capacity.all as specified and as directed. |
| 10 | All as per item No 9 above but for inverter type split AC and split type AC 1.0/1.5 /2.0 Ton capacity. |
| 11 | Servicing of refrigerator by air blowing, cleaning of condenser coil, rubber bedding & checking and tightening the electrical connection all as directed of capacity 165 to 430 Ltrs all as specified and as directed. |
| 12 | Servicing of water cooler by air blowing, cleaning of condenser coil, checking and tightening the electrical connection all as directed for water cooler of capacity 40/80 lts all as specified and as directed. |
| 13 | Supply and fix in replacement of outdoor capacitor 36 + 5% uFD |
| 14 | Supply and fix in replacement of outdoor capacitor 46 + 5% uFD |
| 15 | Supply and fix in replacement of outdoor capacitor 62 + 5% uFD |
| 16 | Supply & replace timer switch for refrigerator of any capacity all as specified and directed. |
| 17 | Supply & replace bimetal switch for refrigerator of any capacity all as specified and directed. |
| 18 | Removing defective over load protector and supply and fixing new over load protector for Deep freezer/ refrigerator of any capacity and testing complete all as specified and as directed. |
| 19 | Supply and fix in replacement of defective fan motor with new fan motor suitable for water cooler/deep freezer of any capacity and testing complete all as directed. |
| 20 | All as per item No 19 above but for outer unit of split AC 1.5 Ton capacity all as specified and directed. |
| 21 | All as per item No 19 above but for outer unit of split AC 2.0 Ton capacity all as specified and directed. |
| 22 | All as per item No 19 above but for outer unit of inverter type split AC of 1.5 Ton capacity all as specified and directed. |
| 23 | All as per item No 19 above but for outer unit of inverter type split AC of 2.0 Ton capacity all as specified and directed |
| 24 | All as per item No 19 above but for inner unit of split AC of 1.5 Ton capacity all as specified and directed. |
| 25 | All as per item No 19 above but for inner unit of split AC of 2.0 Ton capacity all as specified and directed. |
| 26 | All as per item No 19 above but for inner unit of inverter type split AC of 1.5 Ton capacity all as specified and directed. |
| 27 | All as per item No 19 above but for inner unit of inverter type split AC of 2.0 Ton capacity all as specified and directed. |
| 28 | All as per item No 19 above but swing motor of split AC 1.5 /2.0/3.0 Ton capacity all as specified and directed. |
| 29 | M&L for rewinding of defective outdoor unit fan motor of split type AC 1.0/1.5/2.0 ton capacity any capacity and testing complete all as specified and directed. |
| 30 | Removing and Repairs to electronic control PCB for split type AC 1.0/1.5/2.0 ton capacity of existing make all as specified and directed. |
| 31 | All as per item No 30 above but for mega split, towerAC type AC 3.0/ 4.0 ton ton capacity all as specified and directed. |
| 32 | All as per item No 30 above but for inverter type split AC of 1.0/1.5 ton capacity (outdoor & indoor) of existing make all as specified and directed. |
| 33 | Supply and fix in repairs electronic control PCB with panel for 3.0/ 4.0 ton Tower/cassette type AC of existing make all as specified and directed. |
| 34 | Supply and replace electronic control PCB for Smart Inverter Refrigerator all as specified and directed. |
| 35 | Supply and replace sensor / anti ice thermostat for split type AC of any model all as specified and directed. |
| 36 | Supply and replace remote unit for split type AC of any model all as specified and directed. |
| 37 | Supply and replace remote battery 1.5 Volts for split type AC of any model all as specified and directed. |
| 38 | supply and fix in repairs compressor suitable for split type AC 1.5 Ton capacity by removing unserviceable compressor after cutting the refrigerant line including supply and fixing new hermetically sealed compressor unit suitable to operate on 230 volt AC including connecting back the suction & discharge refrigerant lines, vaccumising charging of refrigerant testing and commissioning for smooth functioning all as specified & directed. |
| 39 | All as per item No 38 above, but for 2.0 Ton capacity all as specified and directed. |
| 40 | All as per item No 38 above, but for 4.0 Ton Tower AC capacity all as specified and directed. |
| 41 | All as per item No 38 above, but for inverter type split AC of 1.5 Ton capacity all as specified and directed. |
| 42 | All as per item No 38 above, but for inverter type split AC of 2.0 Ton capacity all as specified and directed. |
| 43 | All as per item No 38 above, but for split type AC 3.0 ton/4.0 Ton capacity, 425 Volts 3 phase all as specified and directed. |
| 44 | Supply and fix push tap CP brass, 15 mm suitable for water cooler of any capacity all as specified and directed. |
| 45 | Material and labour for repair of voltage stabilizer after removing the burnt out unserviceable winding cleaning the slots, insulate properly and rewinding transformer including testing of capacity 5 KVA, single phase, 230 V AC, 50 Hz all as specified and directed. |
| 46 | All as per item No 45 above, but of capacity 3/ 2 /1/0.5 KVA all as specified and directed |
| 47 | Material and labour for repair of voltage stabilizer by replacing time delay relay /main relay unit of voltage stabilizer with new of capacity 5 KVA, 4KVA including testing complete all as specified and directed. |
| 48 | All as per item No 47 above, but of capacity 3/ 2 /1/0.5 KVA all as specified and directed. |
| 49 | Supply and replace service valve for split type AC of 1/4\\" Size all as specified and as directed. |
| 50 | Supply and replace service valve for split type AC of 1/2\\" Size all as specified and as directed. |
| 51 | Supply and replace service valve for split type AC of 5/8\\" Size all as specified and as directed. |
| 52 | Supply & replace condenser unit for split AC of the following type and any make / capacity all as specified and as directed: |
| 53 | All as per item No 52 above, but 1.5 Ton capacity all as specified and as directed |
| 54 | All as per item No 52 above, but 2.0 Ton capacity all as specified and as directed |
| 55 | Supply & replace outer body kit for split type AC of following capacities complete with condenser coil and fan motor complete of existing make all as specified and directed. Note: Compressor, condenser coils and fan motor will be measured and paid separately. |
| 56 | All as per item No 55 above, but 1.5 Ton capacity all as specified and as directed |
| 57 | All as per item No 55 above, but 2.0 Ton capacity all as specified and as directed |
| 58 | Supply and replace copper pipe 1/4\\"all as specified and as directed. |
| 59 | Supply and replace copper pipe 1/2\\"all as specified and as directed. |
| 60 | Supply and replace copper pipe 3/4\\"all as specified and as directed. |
| 61 | Supply and replace copper pip 5/8\\"all as specified and as directed. |
| 62 | Supply and replace flair nut 1/4\\"all as specified and as directed. |
| 63 | Supply and replace flair nut 1/2\\"all as specified and as directed. |
| 64 | Supply & replace drain PVC pipe for split type AC any capacity all as directed. |
| 65 | Supply and replace PC Board of indoor for inverter type split AC of 1.5 to 2.0 ton capacity of existing make all as directed |
| 66 | Supply and replace PC Board of outdoor for inverter type split AC of 1.5 to 2.0 ton capacity of existing make all as directed |
| 67 | S & F Grill for enclosing the outer unit of air conditioners of any capacity |
| 68 | Supply & fix flexible PVC pipe for drinking purpose of any dia suitable for any type of water cooler all as specified and as directed |
| 69 | Supply & replace MS/GI bracket for fixing of outer unit of Air conditioners of capacity 1.5 ton/2.0 ton all as specified and as directed |
| 70 | Supply and replace Metal plug and socket with MCB 20 Amps and steel enclosure all as specified and as directed |
| 71 | Supply and replace MCB SP 5 to 30 Amps 230 Valt as specified and as directed |
| 72 | M&L for sub main wiring surface/ concealed type including cutting chases and making good in CM 1:3 complete with (2 runs of 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth continuity) 1100 Volts grade PVC insulated unsheathed single core multistranded cable FR grade with copper conductor confirming to IS 694 drawn in conduit including provision of suitable dia PVC rigid conduit (medium grade) with conduit accessories such as bends, elbows, saddles all as specified and as directed. |
| 73 | All as per item ser No 72 here in after but for 4x6.0 sq. mm + 1x6.0 sq. mm earth wire All as specified and as directed. |
| 74 | Supply and replace thermo cool insulation for copper pipe for split type AC of any type and capacity.all as specified and as directed |
| 75 | Supply and replace unserviceable fan blade of outdoor unit fan motor of split type AC 1.0/1.5/2.0/ 3.0 ton capacity with new fan blade all as specified and directed. |
| 76 | Complete checking up & servicing of water cooler of Cross field Water Purifiers Pvt Ltd (17 Qty) complete including changing of filter, PC board, UV lamp, UV choke house angle cock tap including pipe connection etc, all as specified and as directed. Note 1 : The work includes changing of filter element, PC board,UV lamp, UV choke, hose, angle cock tap including pipe connection etc as per site requirement and all as specified. The unit rate is deemed to be included for the same. The comprehensive maint of water cooler is inclusive of all services briefly explained above for the following water coolers - 40/80 Ltr capacity 17 Nos under HQ SAC area. Note 02: The technical team of OEM shall visit the cooler every four months (2 times during the contract period). Note 03 : After servicing the cooler, the system shall function detect free till the next service after 4 months in case if the cooler is not working within the time, the technical team should visit the site & the system shall be made functional without any extra cost to the government. |
| 77 | Supply and replace of all filter of water cooler / purifier 'CANTT RO' or any type and capacity of existing make complete all as specified and as directed |
| 78 | Supply and installation of 3/4\\" PVC drain piping system for outdoor motor unit, including all necessary fittings and connections to ensure proper drainage of condensate water complete all as specified and as directed. |
| 79 | Comprehensive and preventive maintenance of DG set of capacity 160 KVA to ensure the generator's reliability, efficiency, and longevity of DG sets. The following key tasks typically to be performed during B & C check of DG set as per the running hours and OEM recommendation .Make of DG Set Ashok Leyland (Mukkunni Mala) /Kirloskar (340 TRU Muttathara ) a) Check and clean fuel injectors.b) Inspect and adjust valve clearances.c) Examine the turbocharger for wear or damage.d) Inspect and clean the air intake system.e) Check the cylinder head and piston rings for wearf) Change the fuel filter, bypass filter and oil filterg) Change the Air filterh) Change the water separatorj) Radiator cleaning with chemical k) Replace the coolant and engine oill) Checking all electrical wiring and replace the unserviceable electromechanical switches, pressure gauges, indicatorsm) Checking the mechanical coupling between alternator shaft and prime mover to reduce the mechanical vibrations during hunting/start/stop of engine /Alternatorn) Testing of emission system and minimise the obstruction by removing and cleaning , leakage arresting in exhaust pipe and Air Filter replacement if required Note1. All tests mentioned above are to be carryout by OEM of DG set .2.Test certificates must be submitted by the contractor duly signed by OEM representative, Engineer in charge and contractor for claiming the RAR.3. All the spare parts required for B & C Check of DG set will be measured and paid under the respective items of the following schedule. all as specified and as directed. |
| 80 | All as per item No 79. here in above but of capacity 125 KVA DG set Kirloskar location- 17 FBSU Service cell all as specified and as directed. |
| 81 | All as per item No79. here in above but of 100 KVA capacity DG Set Kirloskar Location :- 17 FBSU computer cell all as specified and as directed. |
| 82 | All as per item No 79. here in above but of capacity 62.5 KVA capacity DG set Kirloskar Location:-Tarmac Area (Shanghumugham) all as specified and as directed. |
| 83 | All as per item No 79. here in above but of capacity 30 KVA capacity DG set kirloskar Location:-257 SU - D/Area Pump House /17 FBSU Offers Mess all as specified and as directed. |
| 84 | All as per item No 79. here in above but of capacity 25 KVA DG set kirloskar Location:-17 FBSU MAP PH/OTM Accn PH all as specified and as directed. |
| 85 | All as per item No 79. here in above but of capacity 7.5 KVA DG set kirloskar Location:-Mukkinimala Tech Area all as specified and as directed. |
| 86 | Supply only lubrication oil filter element with 'O' ring required at site for 160 KVA capacity DG Sets all as specified and as directed. |
| 87 | All as per item No. 86 here in before but 125 KVA DG set all as specified and as directed. |
| 88 | All as per item No. 86 here in before but 100 KVA DG set all as specified and as directed. |
| 89 | All as per item No. 86 here in before but 62.5 KVA DG set all as specified and as directed. |
| 90 | All as per item No. 86 here in before but 30 KVA DG set all as specified and as directed. |
| 91 | All as per item No. 86 here in before but 25 KVA DG set all as specified and as directed. |
| 92 | All as per item No. 86 here in before but 7.5 KVA DG set all as specified and as directed. |
| 93 | Supply only fuel filter element with 'O' ring as required at site for 160 KVA capacities of DG Set all as specified and as directed. |
| 94 | All as per item No. 93 here in before but 125 KVA DG set all as specified and as directed. |
| 95 | All as per item No. 93 here in before but 100 KVA DG set all as specified and as directed. |
| 96 | All as per item No. 93 here in before but 62.5 KVA DG set all as specified and as directed. |
| 97 | All as per item No. 93 here in before but 30 KVA DG set all as specified and as directed. |
| 98 | All as per item No. 93 here in before but 25 KVA DG set all as specified and as directed. |
| 99 | All as per item No. 93 here in before but 7.5 KVA DG set all as specified and as directed. |
| 100 | Supply only Air filter element inner and outer as required at site with 'O' ring as required at site for 160 KVA DG Sets all as specified and as directed. |
| 101 | All as per item No. 100 here in before but 125 KVA DG set all as specified and as directed. |
| 102 | All as per item No. 100 here in before but 100 KVA DG set all as specified and as directed. |
| 103 | All as per item No. 100 here in before but 62.5 KVA DG set all as specified and as directed. |
| 104 | All as per item No. 100 here in before but 30 KVA DG set all as specified and as directed. |
| 105 | All as per item No. 100 here in before but 25 KVA DG set all as specified and as directed. |
| 106 | All as per item No. 100 here in before but 7.5 KVA DG set all as specified and as directed. |
| 107 | Supply only Solenoled shut off valve assembly complete suitable to operate with 12 volts DC all as specified and as directed. |
| 108 | Supply only Solenoled shut off valve assembly complete suitable to operate with 24 volts DC all as specified and as directed. |
| 109 | Supply only Lube oil pressure sensor for Engine all as specified and as directed. |
| 110 | Supply only Speedo meter cable including outer and inner cable all as specified and as directed. |
| 111 | Supply only Start/Stop Push button switch complete with base all as specified and as directed. |
| 112 | Supply only Ignition switch heavy duty with keys suitable for DG set all as specified and as directed. |
| 113 | Supply only silencer for Genset of capacity 160 KVA all as specified and as directed. |
| 114 | Supply only silencer for Genset of capacity 100 KVA all as specified and as directed. |
| 115 | Supply only gun metal gate/ globe valve with handle, heavy duty, of 15/20mm bore in the fuel line all as specified and as directed. |
| 116 | Supply only 'V' Belts/ pump 'V' belts/ dynamo 'V' belts for 25/ 30 KVA capacity DG set all as specified and as directed. |
| 117 | Supply only 'V' Belts/ pump 'V' belts/ dynamo 'V' belts for 62.5 capacity DG set all as specified and as directed. |
| 118 | Supply only 'V' Belts/ pump 'V' belts/ dynamo 'V' belts for 100 KVA capacity DG set all as specified and as directed. |
| 119 | Supply only 'V' Belts/ pump 'V' belts/ dynamo 'V' belts for 125 KVA capacity DG set all as specified and as directed. |
| 120 | Supply only 'V' Belts/ pump 'V' belts/ dynamo 'V' belts for 160 KVA capacity DG set all as specified and as directed. |
| 121 | Supply only Flexible over flow pipe steel armoured flexible with suitable end sockets of size 15 mm dia of suitable length and size all as specified and as directed. |
| 122 | Supply only lub oil of grade SAE 15 W - 40 all as specified and as directed. |
| 123 | Supply only distilled water for battery all as specified and as directed. |
| 124 | Supply only Coolant suitable for Radiator as per OEM recommendation all as specified and as directed. |
| 125 | Supply only battery of 12 V , 100 AH all as specified and as directed. |
| 126 | Supply only battery of 12 V , 150 AH all as specified and as directed. |
| 127 | Supply only battery of 12 V , 180 AH all as specified and as directed. |
| 128 | Supply only oil level indicator all as specified and as directed. |
| 129 | Supply only Oil drain hose set all as specified and as directed. |
| 130 | Supply only DG set Control unit capacity 25/30KVA all as specified and as directed. |
| 131 | Supply only DG set Control unit capacity 62.5 KVA all as specified and as directed. |
| 132 | Supply only DG set Control unit capacity 125 KVA all as specified and as directed. |
| 133 | Supply only DG set AVR unit capacity 25/30KVA all as specified and as directed. |
| 134 | Supply only DG set AVR unit capacity 62.5 KVA all as specified and as directed. |
| 135 | Supply only DG set AVR unit capacity 100 KVA all as specified and as directed. |
| 136 | Supply only DG set AVR unit capacity 125 KVA all as specified and as directed. |
| 137 | Supply only DG set AVR unit capacity 160 KVA all as specified and as directed. |
| 138 | Supply only temperature gauge as per sample all as specified and as directed. |
| 139 | Disconnection and removing DG set radiator 160KVA , and transporting to work shop for repairs and descaling the radiator thoroughly completely with CTC solution/ any other chemical solvent agent as approved Indian standards , stopping of leakage at place to copper cores and tubes by brazing scrapping the existing oil paint, dusting and painting the radiator with enamelled paint etc., reinstalling and commissioning all as specified and as directed. |
| 140 | All as per item No 139 above but of capacity 125 KVA all as specified and as directed. |
| 141 | All as per item No 139 above but of capacity 100 KVA all as specified and as directed. |
| 142 | S&F in replacement of self starter assembly suitable for 25 KVA DG Set and testing complete all as specified and directed . |
| 143 | S&F in replacement of self starter assembly suitable for 30 KVA DG Set and testing complete all as specified and directed. |
| 144 | S&F in replacement of self starter assembly suitable for 62.5 KVA DG Set and testing complete all as specified and directed. |
| 145 | S&F in replacement of self starter assembly suitable for 100 KVA DG Set and testing complete all as specified and directed. |
| 146 | M&L for repairing of fuel injection pump (FIP) of cap 25 KVA /30 KVA and taking out it to authorised workshop and replacing unserviceable element, delivery valve, balance wait, lever, bearing after repairing fixing to the engine testing for satisfactory function all as directed . |
| 147 | All as per item No.146 here in before but 62.5 KVA DG set all as specified and as directed. |
| 148 | All as per item No. 146 here in before but 160 KVA DG set all as specified and as directed. |
| 149 | M&L for repairing of dynamo including removing from position and remove the burnt out armature , clean the internal surfaces , servicing, supply and fix new armature with brushes and brush holder , necessary lathe work with bushes etc all as specified and as directed. |
| 150 | S&F in replacement of Water pump of any capacity all as specified and as directed. |
| 151 | S&F in replacement of Oil seal assembly of any capacity as per sample all as specified and as directed. |
| 152 | M&L for repairing of 20 /30 KVA alternator and transport to an authorised work shop for repair/rewinding by taking out copper wire from stator and rewinding the same with super enamelled bared copper conductor and varnishing with class F insulation ,and replace the carbon brushes and reassembling the alternator and transporting back and refixing in position , testing and commissioning all as specified and as directed. |
| 153 | All item No.152 above but of capacity 100 KVA/125KVA all as specified and as directed. |
| 154 | Repairs to acoustic enclosure provided for DG sets by necessary welding work/patch-up works, providing new hinges etc including making good the repaired portion by painting to match with the existing all as specified and as directed. |
| 155 | S & F in repairs of Door panels duly hinged and insulated suitable for out door type DG sets acustic enclosure as per sample with hinges and door locks all as specified and as directed. |
| 156 | S & F in repairs of Door locks with catcher (right/left) suitable for out door type DG sets acustic enclosure as per sample with hinges and door locks all as specified and as directed. |
| 157 | S & F in repairs of Grills with frame suitable for acustic enclosure as per sample all as specified and as directed. |
| 158 | S & F in repairs of Side panels thermally insulated suitable for DG acustic enclosure all as specified and as directed. |
| 159 | M&L for repairing of 12V self starter by removing, dismantling and taking it to authorised workshop and replacing unserviceable coil tapping re-fixing to the engine testing for satisfactory function all as directed. |
| 160 | M & L for preparing external surfaces of engine, alternator, connected panel, base frame, radiator, battery stand etc, free from foreign materials and applying one coat of superior quality synthetic enamel paint of approved colour by spray painting, cleaning meter panel and writing MES No to the DG sets of 160 KVA capacity Kirloskar/CUMMINS installed in 257 SU/340TRU with AMF panel and acoustic enclosure all as specified and as directed. |
| 161 | All as per item No 160 above but of 125 to 100 KVA capacity kirloskar make DG set at computer cell at 17 FBSU/MES Service cell with AMF panel and acoustic enclosure all as specified and as directed. |
| 162 | All as per item No 160 above but of 62.5 KVA capacity kirloskar DG set with AMF Panel for 17 FBSU, Tarmac with Acustic enclosure all as specified and as directed. |
| 163 | All as per item No 160 above but of 20 to 30 KVA capacity kirloskar DG set for 17 FBSU, 257SU, with Acustic enclosure all as specified and as directed. |
| 164 | All as per item No 160 above but of 7.5 KVA capacity kirloskar DG set for 17 FBSU, 257SU, with AMF Panel and Acustic enclosure all as specified and as directed. |
| 165 | Supply and replacement of Control contactor including 2 NO-2NC.Make:- TC or equivalent all as specified and as directed. |
| 166 | Supply and replacement of Contactor MCX 22 .Make:- L&T or equivalent all as specified and as directed. |
| 167 | Supply and replacement of Contactor MCX 34. Make:- L&T or equivalent all as specified and as directed. |
| 168 | Supply and replacement of Contactor MCX 33, 415 volt.4P 200A . Make:- L&T or equivalent all as specified and as directed. |
| 169 | Supply and replacement of Contactor MCX 32 415 volt . Make:- L&T or equivalent all as specified and as directed. |
| 170 | Supply and replacement of Contactor MCX 11 , 50 A ,4P,415 V . Make:- Schneider or equivalent all as specified and as directed. |
| 171 | Supply and replacement of Contactor MCX04 four pole . Make:- L&T or equivalent all as specified and as directed. |
| 172 | Supply and replacement of Contactor MCX03 four pole . Make:- L&T or equivalent all as specified and as directed. |
| 173 | Supply and replacement of Contactor 4 pole 250 A make.L&T or equivalent all as specified and as directed. |
| 174 | Supply and replacement of Contactor 4 pole 180 A make.L&T/Schneider or equivalent all as specified and as directed. |
| 175 | Supply and replacement of Contactor magnetic coil MCX22 .Make:- L&T or equivalent all as specified and as directed. |
| 176 | Supply and replacement of Contactor magnetic coil MCX34. Make:- L&T or equivalent all as specified and as directed. |
| 177 | Supply and replacement of Contactor magnetic coil MCX33, 415 volt. . Make:- L&T or equivalent all as specified and as directed. |
| 178 | Supply and replacement of Contactor magnetic coil MCX32 415 volt . Make:- L&T or equivalent all as specified and as directed. |
| 179 | Supply and replacement of Contactor magnetic coil MCX04 four pole . Make:- L&T or equivalent all as specified and as directed. |
| 180 | Supply and replacement of Contactor magnetic coil MCX03 four pole . Make:- L&T or equivalent all as specified and as directed. |
| 181 | Supply and replacement of Contactor coil suitable capacity for 100 to 160KVA DG set. Make :- L&T or equivalent all as specified and as directed. |
| 182 | M&L for preventive maintenance of AMF panel of DG set of capacity 160KVA by replacing defective wiring circuits as per colour code, cut outs etc all as specified and directed. |
| 183 | M&L for preventive maintenance of AMF panel of DG set of capacity 125KVA by replacing defective wiring circuits as per colour code, cut outs etc, all as specified and directed. |
| 184 | M&L for preventive maintenance of AMF panel of DG set of capacity 100KVA by replacing defective wiring circuits as per colour code, cut outs etc all as specified and directed. |
| 185 | M&L for preventive maintenance of AMF panel of DG set of capacity 62.5KVA by replacing defective wiring circuits as per colour code, cut outs etc, all as specified and directed. |
| 186 | M&L for preventive maintenance of AMF panel of DG set of capacity 7.5KVA by replacing defective wiring circuits as per colour code, cut outs etc all as specified and directed. |
| 187 | Supply and replacement of Selector switch 16 A 2 pole 2 way. Make:- Zalzer or equivalent all as specified and as directed. |
| 188 | Supply and replacement of VMR/Single phase preventer . Make:-Minilac or equivalent all as specified and as directed. |
| 189 | Supply and replacement of Add on block 2No-2NC. Make:- TC or equivalent all as specified and as directed. |
| 190 | Supply and replacement of 12V/24V 11 pin PLA relay with base all as specified and as directed. |
| 191 | Supply and replacement of Timer delay relay 220V. Make:- Selectron or equivalent all as specified and as directed. |
| 192 | Supply and replacement of Indicator lamp/push button/element all as per sample all as specified and as directed. |
| 193 | Supply and replacement of AMF controller of DG set of any cap. Make:- C&S Siemens/L&T all as specified and as directed. |
| 194 | Supply and replacement of Water separator filter for DG set of 25 to 62.5 KVA. Make:- MICO/BOSS/Kirloskar all as specified and as directed. |
| 195 | Supply and replacement of Water separator filter for DG set of 100 to 160 KVA. Make:- MICO/BOSS/Kirloskar all as specified and as directed. Note:- (a) Any emergency complaints of DG set which cause interruption for providing stand by supply to User shall be attended by the Contractor within 8 hours after receiving the complaint by telephonically/through writing from concerned JE E/M/AGE E/M. In case of any delay in attending the complaint more than 8 hrs. after handing over of emergency / urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. If the nature of job is such that the work cannot be completed within period of 8 hrs. then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Charge more than eight hrs. after handing over works of urgent nature to the contractor. if the delay is more than twelve hrs. period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 500/- per job/day shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW -2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Dep't. The decision of the Accepting Officer in this regards shall be final and binding. (c) The contractor shall maintain a record of all urgent work at and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt. |
| 196 | Taking out unserviceable UG cables and Supply and laying only in trenches or passing through pipes/ poles etc LT XLPE cable heavy duty 1100 Volts grade with aluminium conductor of the following connections with provn of cable lugs and glands as required of 6 Sqmm 4 core all as specified and as directed. |
| 197 | Supply and laying in trenches or passing through pipes/ poles etc LT XLPE cable heavy duty 1100 Volts grade with aluminium conductor of the following connections with provn of cable lugs and glands as required of 6 Sqmm 4 core all as specified and as directed. |
| 198 | All as per item No.197 above but of size 50 sq. mm 3.5 core all as specified and as directed. |
| 199 | All as per item No.197 above but of size 70 sq. mm 3.5 core all as specified and as directed. |
| 200 | M&L replacement of manual changeover switch with metal enclosure, 4 pole front operated,415V, 100A with complete accessories including cable lugs etc, all as specified and directed. |
| 201 | M&L replacement of manual changeover switch with metal enclosure, 4 pole front operated,415V, 250A with complete accessories including cable lugs etc, all as specified and directed. |
| 202 | Supply and fixing in replacement HOT moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 270 mm x 225 mmx 135 mm ( inside dimension) incl 4 way heavy duty terminal block with 01x MCB 10 Amps SP, 10 KA and two number of PVC cable entry gland of standard size with suitable GI bracket to fix with pole, including taking down existing complete all as specified and as directed. Make: Sintex or equivalent in Hansel |
| 203 | M& L for 3 core 1.0 Sqmm multistranded copper conductor PVC insulated unsheathed cable to connect from junction box to street light fitting drawn through and including rigid non metallic PVC conduit medium grade fixed on pole by means of clamps made out of MS flat irons and connecting from terminal box to light fitting and testing including taking down perished wiring complete all as directed complete all as specified and directed |
| 204 | Supply and fixing in replacement of 45W street light with prismatic polycarbonate modular secondary lens optics, with a finless design made of non-corrosive high-pressure die-cast aluminium housing, 4Kv inbuilt SPD with top opening driver cover for easy maintenance, efficiency > 110 lm/ watt, Ingress protection (IP) 66 with an IK rating of 08. make equivalent. Make : Bajaj Part No ENXT P 54L WH PO PC SD/ Havells/ Phillips all as specified and as directed. |
| 205 | Supply and fixing in replacement of 70W street light with prismatic polycarbonate modular secondary lens optics, with a finless design made of non-corrosive high-pressure die-cast aluminium housing, 4Kv inbuilt SPD with top opening driver cover for easy maintenance, efficiency > 110 lm/ watt, Ingress protection (IP) 66 with an IK rating of 08. make equivalent. Make : Bajaj Part No ENXT P 54L WH PO PC SD/ Havells/ Phillips all as specified and as directed. |
| 206 | Supply & fixing post top LED light 20 watts made in spun aluminium powder coated housing with high efficiency lighting & IP 65 protection all as specified and directed. Make: Bajaj Part No BGCTNP 20W LED WH/ Havells/ Phillips |
| 207 | M&L for road cutting, including excavation, returning filling in, spreading, levelling, well ramming in layers, soiling with broken boulders/ stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work, complete all as specified and as directed. |
| 208 | M& L for taking out old garden light and Supply & Fix of Bollard Light having height 500mm made out of galvanized MS Sheet by Laser cutting and welding the same, with 12Watt LED , LED Mounting of MCPCB, inbuilt driver, 230V, 50Hz , duly powder coated finish complete etc. as Reqd. Hi-Lite Make. Cat No HL-156 or equivalent in Havells / Crompton all as specified and as directed. |
| 209 | S& F of LED light fitting out door type IP 65 rated LED 20 watts post top ideal to light up to parks, garden and hertage site including taking down old existing and necessary arrangement to fix the light on decorative pole Make : Crompton Part No LPTH-20-CDL all as specified and as directed. |
| 210 | M&L for in replacement GI bracket of 1.5 mtr long from its existing location i.e.. Bldg /pole and supply and fix with 32 mm dia light GI pipe complete all as specified and directed |
| 211 | M& L for 5 core 1.5 Sqmm multistranded copper conductor PVC insulated unsheathed cable to connect from junction box to high mast pole junction box including taking down perished wiring complete all as directed complete all as specified and directed |
| 212 | Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying UG cable not exc 1.5m in depth and getting out in soft soil complete all as specified and directed |
| 213 | Removing excavated material(soil) not exc 50m and depositing where as directed at a level not exc 1.5m above the starting point complete all as specified and directed |
| 214 | Returning, filling of excavated soil upto a depth upto 25 cm after riddling the excavated soil for cushioning of cable and refilling of trench with normal excavated soil all as specified and as directed. |
| 215 | Supply and lay in trenches burnt bricks sub-class ‘B’ of size 150 x115x75 for cable protection complete all as specified and directed |
| 216 | M/L for PCC 1:2:4 Type B1 with 20 mm graded aggregate for coping , over road cutting surface complete including necessary foam work complete all as specified and directed |
| 217 | M/L for PCC 1:3:6 Type C1 with 12.5 mm graded aggregate for coping , over road cutting surface complete including necessary foam work complete all as specified and directed |
| 218 | S&F in replacement of MCCB 63 A,3P,25 KA incl necessary fixing arrangements complete all as specified and as directed. |
| 219 | S&F in replacement of MCCB 100 A,3P,25 KA incl necessary fixing arrangements complete all as specified and as directed. |
| 220 | S&F in replacement of MCCB 125 A,4P,25 KA incl necessary fixing arrangements complete all as specified and as directed. |
| 221 | S&F in replacement of MCCB 160 A,4P,25 KA incl necessary fixing arrangements complete all as specified and as directed. |
| 222 | S&F in replacement of MCCB 200 A,4P,25 KA incl necessary fixing arrangements complete all as specified and as directed. |
| 223 | S&F in replacement of MCCB 250 A,4P,25 KA incl necessary fixing arrangements complete all as specified and as directed. |
| 224 | S&F in replacement of MCCB 400 A,4P,25 KA incl necessary fixing arrangements complete all as specified and as directed. |
| 225 | Supply and fix in replacement of heat shrinkable cable joint kit of size 3.5 c x 10 Sqmm to 16 Sqmm all as specified and as directed. |
| 226 | Supply and fix in replacement of heat shrinkable cable joint kit of size 3.5 c x 25 Sqmm to 50 Sqmm all as specified and as directed. |
| 227 | Supply and replacement of GI pipe (Light Grade) 80 mm bore for protection of underground cable, including dismantling and removing unserviceable pipe, excavation in any type of soil, laying and jointing of new GI pipe complete with all necessary fittings, refilling, ramming, disposal of dismantled material up to 50 m lead, and restoration of disturbed surface to original condition, complete all as specified and directed. |
| 228 | AS per item no:227 but for 50 mm all as specified and as directed. |
| 229 | M&L for Replacement of Earthing complete by using GI earth plate electrode 60cm × 60cm × 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less 'than 1.5 metres below normal ground level, connected to using GI earth lead of size 4mm dia by means of bolts, nuts, check nuts and washers etc made of galvanised iron and protected by galvanised iron light grade 25 mm bore & 20mm dia galvanised medium grade for watering and including funnel, wire mesh, RCC 1:2:4 cover slab 50 mm thick with re-enforcement of 8 mm TMT bars @ 100mm c/c both directions and PCC chamber with PCC 1:3:6 type C2 including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m, charcoal, lugs, common salt complete all as specified and as shown on plate No.3 of SSR Part-I all as specified and as directed. |
| 230 | M&L for Replacement of Earthing complete with copper earth plate electrode 60cm x 60cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connecting copper strip of size 25mm x 3mm from earth plate to body of the equipment/LT Panel by means of bolts, nuts, check nuts and washers of brass or steel, 40 mm bore GI light grade pipe for protection of earth strip from earth plate(7.5 mtrs long), 20 mm GI light grade watering pipe, PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in earhing pit, PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing on completion till to achieve desired ER value all as specified and shown in electrical plate No.3 of MES Schedule part-I all as specified and as directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |