| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. |
| 2 | Excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering . All works upto plinth level 1:4:8 mix (1 cement: 4 coarse sand:8 graded stone aggregates) 40 mm nominal size (crushed) |
| 4 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 6 | 52mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 liter per 50kg of cement or as per manufacturer’s specifications, including cost of cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. |
| 7 | Supply & fixing of 40mm wide strips of joints |
| 8 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including Admixtures in recommended proportions, (as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge .All work upto plinth level. |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 10 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 11 | Centring and shuttering including strutting, propping etc. and removal of form work for Lintel, beams, plinth beams, girders, bressumers and cantilevers |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form work for :- Foundations, footings, bases of columns. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form work for :- Columns, pillars, piers. |
| 14 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 15 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 16 | Providing and fixing Insulated HIRIB colour coated iron profile sheets 0.47 mm (+ 0.05 %) total painted thickness with under layer of 5 mm thick prefixed XLP insulation with aluminium foil having minimum yield strenght of 550 MPa. Sheet should have hot dip AZ-70 coating of minimum 70gsm/sqm as per IS 15961 and total coated thickness of 18-20 micrins and should be supplied in single length upto 12 metre size, shape and pitch of corrugation as approved by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (TATA / JSW or Equivalent) |
| 17 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm |
| 18 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including:a) Structural analysis & design and preparation of shop drawings for pressure equalization or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metallic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanized with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bimetallic contacts all complete required to perform as per specification and drawing The item includes cost of all material &labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as perthe approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 19 | Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in-Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevant Item*).(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35%, Light reflection internal 10 to 15%, light reflectionexternal 10 to20%, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 20 | Providing and fixing, in position concealed G.I section for wall panelling using board of required thickness fixed on the ‘W’ profile (0.55mm thick) having a knurled web of 51.55mm and two flanges of 26mm each with lips of 10.55mm placed @ 610mm C/C in perimeter channel having one flange of 20mm and another flange of 30mm with thickness of 0.55mm and web of length 27mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @ 610mm C/C with fully threaded self-tapping dry w all screws. Board is fixed to the ‘W’ profile with 25mm countersunk ribbed head screws @ 200mm C/C, all complete as per the drawing and directions of engineer- in-charge. The joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish Multipurpose cement board reinforced with suitable fibre cement screw. 8 mm thick cement fibre board as per IS : 14862 |
| 21 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick |
| 22 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 23 | Wall Painting with acrylic emulsion paint of approved brand andmanufacture to give an even shade. Two or more coats on new work |
| 24 | Providing and fixing Factory made Steel Door with Heavy Duty Frames, complete with all necessary Fitting and fixtures |
| 25 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For fixed portion Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 26 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 27 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.) With float glass panes of 4 mm thickness (weight not less than 10.0 kg / sqm) |
| 28 | Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete. With Galvanized M.S. Wire gauge with wire of dia 0.63 mm 9.9.1.2 With 12 mm mild steel U beading |
| 29 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm |
| 30 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm |
| 31 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre |
| 32 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion 110 mm Bend 87.5° |
| 33 | Providing and Fixing of LED light 3 D letters / LOGO BOARD including all necessary wiring, all complete as per direction of engineer incharge |
| 34 | Cleaning of Floor and treatment of floor with Self leveling Material to remove undulations and installation of new Shock absorbing, Anti Skid, Abrasion Resistant & Easy to Maintain indoor sport flooring with an overall thickness more than 6.50 mm and wear layer of minimum 1.00 mm, synthetic sport surface comprising of Glass Fibre Tissue reinforced with low shrinkage dimensional stability: Weight: 4.30 kg/m2, Shock Absorption : 30%, Sliding Coefficient : 0.42-0.60, Energy Return : 0.42, Ball Rebound : 93% Vertical Deformation : 1.5 Abrasion Resistance : 0.15, Residual Imprint: 0.15mm, Resistance : >6, Chemical Resistance : Excellent, Dimensional Stability : <0.1%. with PUR surface Protection.The Product Should be procured from manufacturers approved by BWF grade-1 only with warrenty of 3 years and shall be installed after prior approval of Engineer Incharge. |
| 35 | 12mm Cement plaster finished with a floating coat of neat cement of mix:: 1 : 4 ( 1 cement : 4 coarse sand) |
| 36 | Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent. |
| 37 | Add provision for Design and vetting of Structural Drawings from IIT/NIT/ design Directorate |
| 38 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, leadupto 50 meter and lift upto 1.5m, as directed by Engineer-in-Charge.All kinds of soil : |
| 39 | Providing and laying in position specified grade of cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 40 | Supply and installation of Synthetic Artificial Turf for Football field from a FIFA Preferred producer of any country/ Standard Licence of european & American make only having polyethylene monofilament diamond shaped yarn, Pile height of 50-60mm, triple layered PU backing, stitch rate of 150-160 stitches per linear metre, UV Resistant Slit Film Yarn structure, Detex not less than 14,000 , Tape thickness not less than 130 microns, Pile weight not less than 1500 gms/sqm, total carpet weight not less than 1900 gms/sqm, OR AS APPROVED BY FIFA with Infill weight not less than 38 kgs/ sqm, (silica sand of 80/100 grade and SBR rubber granules of size 2- 4mm), total product weight not less than 40,000 gms / sqm. 100 mm wide Line markings should be pre tufted & made of coloured turf of same quality. Cost includes unloading and staging of rolls, sewing of seams with imported turf adhesive, infilling with appropriate dispensing machine, spreading and leveling equipment, brushing of fibers with hydraulic controlled equipment & Annual field maintenance of 3 years. (Regular Turf Brusing by mechanical brushing machine and adding silica sand ruber granulers where required, Joint/Seam rectification included in Annual Maintenance) |
| 41 | Supply and installation of multipurpose turf for cricket ptactice net wickets with PE texturised monofilament Yarn with minimum pile height of 9 mm of european make only with 3 years warrenty |
| 42 | Providing of fixing of Moveable poles with net and line marking for Futsal (volleyball and football) |
| 43 | Providing and fixing of heavy duty net of thickness 2.5mm (mesh size 48x48 mm) to cover the box cricket |
| 44 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: 2.8.1 All kinds of soil : |
| 45 | Steel work welded in built up section framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer. |
| 46 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 47 | Providing and fixing G.I Chain link Fabric fencing of required width in mesh size 50x50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required complete as per direction of Engineer in Charge Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade |
| 48 | Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) |
| 49 | Manufacturing supplying and fixing retro reflective overhead signage boards made up of 2mm thick aluminum sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type-III of ASTM-D-4956-01 as approved by Engineer-in-charge; letters, borders etc. as per IRC : 67-2001 in silver white with blue colour background and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class -II of ASTM-D-4956- 01 and fixing the same to the plate of structural frame work by means of suitable sized aluminum alloys, rivets |
| 50 | Providing and fixing Satin cloth flags with sports council logo |
| 51 | Centering and shuttering including strutting, propping etc. and removal of form work for: Edges of slabs and breaks in floors and walls |
| 52 | Providing & laying PP (polypropylene ) tile approved by FIBA with thickness and other specification like Ball Rebound, slip resistance, force reduction as per parameters approved by FIBA. The contractor shall have to provide the unconditional warrenty of 3 years from the OEM or its Authorised Distributor in India |
| 53 | Providing and fixing of fixed height adjustable pickle ball poles with net and anteena |
| 54 | Provision for supply and Installation of Pedestal for Inaguration / Foundation made of Brick work with Tile work for fasard and Granite Plate |
| 55 | carriage of sand |
| 56 | carriage of stone aggregate Please Enable Macros to View BoQ information |