| 1 | all-suture anchor/ soft anchor, dia 2.9mm, double-loaded with fiber wire (usp size 2)(different colors) with needle, loaded on self-punching rigid disposable driver - sterile |
| 2 | PEEK Tenodesis Cannulated Screw, dia 4mm and 5mm, Length 10 mm to 20 mm - Sterile |
| 3 | Fiber Tape, size 2 , Len 39\\", with both end round, Tape working length 15\\" with needle (Colour : White-Blue, White-Black) - Sterile |
| 4 | Fiber Tape, size 1.4 , Len 39\\", with both end round,Tape working length 15\\" with needle(Colour : White-Blue, White-Black) - Sterile |
| 5 | Ankle Syndesmosis Kit, dia 3mm, Ti Oblong Button and Ti round Tapered Button with Adjustable Loop (Knotless) - Sterile |
| 6 | Fiber Tape, Size 2 , Len 19\\", with flat end -Sterile |
| 7 | Ankle Achilles Tendon Repair Kit.- SterileComprise of : Self-Punching Suture Anchor, Knotless, dia. 4.75mm, with PEEK eyelet & PEEK screw, loaded on disposable driver, (4pcs)Fiber Tape, size 2 , Len 39\\", with both end round, Tape working length 15\\" with needle (Colour : White-Blue, White-Black) - 2 pcs |
| 8 | Ankle Syndesmosis Kit - SterileComprises of : Ankle Syndesmosis Kit, dia 3mm, Ti Oblong Button and Ti round Tapered Button with Adjustable Loop (Knotless),Suture Passing Pin, Spade- Tip (Beath Pin) Dia. 3.2mm; Len. 250mm, |
| 9 | ATFL Repair Kit - SterileComprises of : Self-Punching Suture Anchor, Knotless, dia. 4.75mm, with PEEK eyelet & PEEK screw, loaded on disposable driver , (1pcs)PEEK Suture Anchor, Knotless, dia. 3.5mm, Open eyelet with Screw (Total Length 12.5mm), loaded on disposable driver (1 pcs)PEEK Suture Anchor, dia 3.0mm, Double-Loaded Fiber Wire (USP Size 2)(different colors) with Needle, loaded on disposable Driver (2 pcs)Fiber Tape, Size 2 , Len 19\\", with flat end (1 pcs) |
| 10 | Titanium Suture Anchor, dia 1.8 / 2.0 mm, Loaded with One Fiber Wire with Needle, loaded on disposable Driver - Sterile |
| 11 | PEEK Suture Anchor, dia 1.8 / 2.0 mm, Loaded with One Fiber Wire with Needle, loaded on disposable Driver - Sterile |
| 12 | PEEK Suture Anchor, Knotless, dia 2.0 mm, , loaded on disposable Driver - Sterile |
| 13 | PEEK Suture Anchor, Knotless, dia. 3.5mm, Open eyelet with Screw (Total Length 8mm), loaded on disposable driver – Sterile |
| 14 | All-Suture Anchor/ Soft Anchor, dia 1.2 mm, with Fiber Tape 0.7 mm, with Needle, loaded on disposable Driver - Sterile |
| 15 | Fiber Tape Size 0.7mm, Len 12\\", Flat End – Sterile |
| 16 | Titanium Attachable Button, dia 2.5 mm, with 2 Holes -Sterile |
| 17 | Adjustable Fiber Loop with, dia 2.5mm Ti flat Button and Ti round Tapered Button , Knotless, with Pulling Suture for DRUJ repair - Sterile |
| 18 | Adjustable Fiber Loop with, dia 2.5mm One Ti flat Button, Knotted - Sterile for CMC repair |
| 19 | Disposable Osteochondral Repair Kit, Assorted Sizes (Sizes dia 4.75, 6, 8, 10) – SterileComprise each pcs of: (Donor Harvester, Tamp, Alignment Rod, Core Extractor Tamp) |
| 20 | High Tibial Osteotomy medial open wedge Variable Angle Plate with 8 Holes, with 5mm Locking Screws (8 pcs), Titanium – SterilePlate and screws are MRI compatible.System options available: HTO, HTO with ACL, and HTO with root repair.Non-locking screws for compression option should be available in 4.5mm diameter. |
| 21 | Distal Femoral Osteotomy Lateral opening wedge Variable Angle Plate with 8 Holes (Left/ Right), with 5mm Locking Screws (8 pcs), Titanium - SterilePlate and screws are MRI compatible.Non-locking screws for compression option should be available in 4.5mm diameter. |
| 22 | Distal Femoral Osteotomy Medial opening wedge Variable Angle Plate with 8 Holes (Left/ Right), supplied with 5mm Locking Screws (8 pcs), Titanium -SterilePlate and screws are MRI compatible.Non-locking screws for compression option should be available in 4.5mm diameter. |
| 23 | Radial Head Prosthesis, Titanium – Modular - Sterile (Comprise of : 1 pcs of Stem and 1 pcs of Modular Head) Stem Sizes: 1, 2, 3 Square DesignStem Size : 1,2,3 Round Design (Lenght 40-50mm)Head Sizes: Small, Medium, LargeHead Dia: 18–22mm, Neck Length: 3–9mm |
| 24 | Total Elbow Replacement - Sterile - (Comprise of :1 pcs of Humeral Stem and 1 pcs Ulna Component) Comprises of: Humeral Stem – Small, Medium, Large and Small(Extra Long) (Pack includes Locking Pin)Ulnar Component – Left and Right, Sizes 7mm, 9mm for small, Large, Extra Long |
| 25 | Hemi Shoulder Arthroplasty - Sterile (Comprise of :1 pcs of Humeral Stem and 1 pcs Humeral Head) Comprises of :Humeral Stem : dia : 6,6.5,7.5,8.5mmHumeral Head : dia : 37 to 45mm, neck Length : 12 - 21mm |
| 26 | Disposable All-Inside ACL Reconstruction Retro Reamer Set (Sizes 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, and 10.0 mm.) - Sterile. |
| 27 | Disposable Suture Passing Pin, Spade- Tip (Beath Pin) Dia. 4.7mm; Len. 355mm - Sterile |
| 28 | Disposable Suture Passing Pin, Drill Tip (Beath Pin) Dia. 2.4mm; Len. 355mm - Sterile |
| 29 | Disposable Suture Passing Pin, Drill Tip Dia. 2.4mm; Len. 200mm -Sterile |
| 30 | Disposable Suture Passing Pin, Spade- Tip (Beath Pin) Dia. 3.2mm; Len. 250mm -Sterile |
| 31 | Disposable Suture Passing Sleeve With Meniscal Knot Pusher / Cutter for the all inside Meniscus repair Kit. |
| 32 | Disposable Suture Passing wire, Trocar Tip with Loop Dia.1.5mm Len. 250mm |
| 33 | Disposable Suture Passer 45°, Left/Right - - Sterile |
| 34 | Disposable Nitinol Loop Wire for Suture Passer - Sterile |
| 35 | Disposable Cannula Trocar Set Dia. 6.5mm/8.5mm, Len. 70mm - Sterile |
| 36 | Disposable Shaver Blade Aggressive Full Radius Plus dia 3.4 mm / 4.2mm |
| 37 | Disposable Shaver Burr Aggressive Round/ Oval Dia. 2.9/5.5mm |
| 38 | Disposable RF Probe 90°/Hook type |
| 39 | Disposable Nitinol flexible needle for the automatic suture passer for Knee/Shoulder - Sterile |
| 40 | All suture anchor with intellibraid technology, curved & straight instrumentation guide for instability repair and can be used in both shoulder and hip repair -2.3 mm anchor with 2 strand Has tag 2 force fiber (Box of 5) |
| 41 | All suture anchor with intellibraid technology, curved & straight instrumentation guide for instability repair and can be used in both shoulder and hip repair -2.3 mm anchor with 3 strand Has tag 2 force fiber (Box of 5) |
| 42 | All suture anchor with intellibraid technology, curved & straight instrumentation guide for instability repair and can be used in both shoulder and hip repair -2.3 mm anchor with 2 strand Has tag 5 force fiber (Box of 5) |
| 43 | 1.4 mm disposable drill with self-centric technology-(Box of 5) |
| 44 | 2.3 mm disposable drill with self-centric technology-(Box of 5) |
| 45 | PEEK ANCHOR FOR GLENOID with flexible inserter with laser marks for reference point to ensure the depth of insertion, curved and straight instrumentation guide for instability repair, curved guide should be available in 0, 12 and 25 degree option, 3.5 mm |
| 46 | PEEK ANCHOR FOR GLENOID with flexible inserter with laser marks for reference point to ensure the depth of insertion, curved and straight instrumentation guide for instability repair, curved guide should be available in 0 degree option, 3.5 mm |
| 47 | PEEK ANCHOR FOR GLENOID with flexible inserter with laser marks for reference point to ensure the depth of insertion, curved and straight instrumentation guide for instability repair, curved guide should be available in 12 degree option, 3.5 mm |
| 48 | PEEK ANCHOR FOR GLENOID with flexible inserter with laser marks for reference point to ensure the depth of insertion, curved and straight instrumentation guide for instability repair, curved guide should be available in 25 degree option, 3.5 mm |
| 49 | Disposable flexible drill with hard stop to ensure accurate size of pilot hole, should run in both forward in reverse direction and can be used in both shoulder and hip repair- (Box of 5) |
| 50 | PEEK anchor for Rotator Cuff :- anchor should be threaded with large handle for better grip and ergonomics with needle- 6.5 mm sizes with Has tag 2 force fibre suture |
| 51 | PEEK anchor for RC :- anchor should be threaded with large handle for better grip and ergonomics without needle- 5.5 mm with Has tag 2 force fibre suture |
| 52 | PEEK anchor for RC :- anchor should be threaded with large handle for better grip and ergonomics without needle- 6.5 mm sizes with Has tag 2 force fibre suture |
| 53 | Hydroxyapatite (HA) (25percentage)and non-crystalline poly-L-lactide (PLLA) (75percentage) composite anchor with easy suture sliding- 6.5 mm with 1.3mm UHMWPE tape sutures made up of two different color Has tag 2 UHMWPE braided with polyester covering for ease of arthroscopic color differentiation and suture handling. |
| 54 | Hydroxyapatite (HA) (25percentage)and non-crystalline poly-L-lactide (PLLA) (75percentage) composite anchor with easy suture sliding- double loaded anchor - 6.5 mm |
| 55 | Hydroxyapatite (HA) (25percentage)and non-crystalline poly-L-lactide (PLLA) (75percentage) composite anchor with easy suture sliding- triple loaded anchor - 5.5 mm |
| 56 | Hydroxyapatite (HA) (25percentage)and non-crystalline poly-L-lactide (PLLA) (75percentage) composite anchor with easy suture sliding- triple loaded anchor - 6.5 mm |
| 57 | Titanium suture Anchor:- threaded with large handle for better grip and ergonomics- 3 mm glenoid anchor, pre-loaded with one strand of Has tag 2 force fiber-(Box of 5) |
| 58 | Titanium suture Anchor:- threaded with large handle for better grip and ergonomics- 6.5 mm anchore with needles pre-loeaded with two strands of Has tag 2 force fiber-(Box of 5) |
| 59 | Titanium suture Anchor:- threaded with large handle for better grip and ergonomics- 3 mm Glenoid anchor, pre-loaded with one strand of Has tag 2 suture-(Box of 5) |
| 60 | Titanium suture Anchor:- threaded with large handle for better grip and ergonomics- 5mm anchor pre-loaded with two strands of Has tag 2 suture, one eyelet-(Box of 5) |
| 61 | Knotless lateral row suture anchor (BIOCOMPOSITE):- With control over repair, should expand from 5.5 mm upto 6.5 mm with incremental tensioning, with sharp metal tip that makes instrumentation optional, with proximal BIOCOMPOSITE eyelet to help protect against tuberosity |
| 62 | Knotless lateral row suture anchor (BIOCOMPOSITE):- With control over repair, should expand from 5.5 mm upto 6.5 mm with incremental tensioning, with sharp PEEK tip that makes instrumentation optional, with proximal BIOCOMPOSITE eyelet to help protect against tuberosity |
| 63 | Disposable shoulder cannula with introducer - 5 mm with Thread- ( Box of 5) |
| 64 | Disposable shoulder cannula with introducer - 5 mm without Thread- ( Box of 5) |
| 65 | Fixed loop femoral fixation device- Size of button should be 4mm x 13mm to maximize button strength on Femoral Cortex, Should have a lead and a flip suture to assist in flipping the button and providing tactile feedback that it has flipped |
| 66 | Fixed loop femoral fixation device- Size of button should be 4mm x 13mm to maximize button strength on Femoral Cortex, Should have a lead and a flip suture to assist in flipping the button and providing tactile feedback that is has flipped |
| 67 | Fixed loop femoral fixation device- Size of button should be 4mm x 13mm to maximize button strength on Femoral Cortex, Should have a lead and a flip suture to assist in flipping the button and providing tactile feedback that is has flipped |
| 68 | Fixed loop femoral fixation device- Size of button should be 4mm x 13mm to maximize button strength on Femoral Cortex, Should have a lead and a flip suture to assist in flipping the button and providing tactile feedback that is has flipped, Should have an attached fixed loop size of 10mm |
| 69 | Fixed loop femoral fixation device- Size of button should be 4mm x 13mm to maximize button strength on Femoral Cortex, Should have a lead and a flip suture to assist in flipping the button and providing tactile feedback that is has flipped, Should have an attached fixed loop size of 15mm |
| 70 | Fixed loop femoral fixation device- Size of button should be 4mm x 13mm to maximize button strength on Femoral Cortex, Should have a lead and a flip suture to assist in flipping the button and providing tactile feedback that is has flipped, Should have an attached fixed loop size of 20mm |
| 71 | Fixed loop femoral fixation device- Size of button should be 4mm x 13mm to maximize button strength on Femoral Cortex, Should have a lead and a flip suture to assist in flipping the button and providing tactile feedback that is has flipped, Should have an attached fixed loop size of 25mm |
| 72 | Fixed loop femoral fixation device- Size of button should be 4mm x 13mm to maximize button strength on Femoral Cortex, Should have a lead and a flip suture to assist in flipping the button and providing tactile feedback that is has flipped, Should have an attached fixed loop size of 30mm |
| 73 | Titanium Screw, fully threaded, cannulated for 1.5mm Guide Wire, indicated for BTB and soft tissue grafts, Should have tapered tip for easy insertion size |
| 74 | HA/PLLA Composite Screw, Should be made of HA (25percentage)/ PLLA (75percentage) , Should be of wedge shaped design for easier insertion and excellent fixation,Should have rounded thread design which helps provide graft protection during insertion. |
| 75 | HA/PLLA Composite Screw size 6mm x 23mm |
| 76 | HA/PLLA Composite Screw size 6mm x 28mm |
| 77 | HA/PLLA Composite Screw size 12mm x 28mm |
| 78 | HA/PLLA Composite Screw size 12mm x 35mm |
| 79 | Titanium suture disc(Round hole) - A titanium attachable cocave round disc of 14mm diameter size with mid round shape 2 openings for facilitation of fibre wires / Tapes |
| 80 | Titanium suture disc(D hole) - A titanium attachable cocave round disc of 14mm diameter size with mid D shape 2 openings for facilitation of fibre wires / Tapes |
| 81 | Titanium suture post screw 25mm : A 6.5mm self tapping 25mm length titanium suture post with flat head design that eliminates need for washer when tying sutures around a post |
| 82 | Titanium suture post screw 30mm : A 6.5mm self tapping 30mm length titanium suture post with flat head design that eliminates need for washer when tying sutures around a post |
| 83 | Titanium suture post screw 35mm : A 6.5mm self tapping 35mm length titanium suture post with flat head design that eliminates need for washer when tying sutures around a post |
| 84 | inside out Left A sterile disposable cannula attachment for left knee posterior horn to midbody inside out meniscal repair. The cannula should be able to rotate 360 degree in order to adjust optimal angle and able to easily pass 2-0 UHMWPE or 0.9mm UHMWPE tape through the same. |
| 85 | inside out right A sterile disposable cannula attachment for right knee posterior horn to midbody inside out meniscal repair. The cannula should be able to rotate 360 degree in order to adjust optimal angle and able to easily pass 2-0 UHMWPE or 0.9mm UHMWPE tape through the same. |
| 86 | Inside out handle A sterile, disposable handle for controlled 1 cm increment of the disposable needles for facilitating ease of inside out meniscal repair and handle should be compatible with different zone specific disposable cannulas. |
| 87 | Inside out repair Tape: A disposable, sterile pair of standard length stainless steel flexible needles looped together with 96.5 cm length of 0.9mm wide UHMWPE tape for easy inside out meniscal repair. |
| 88 | Inside out repair Suture: A disposable, sterile pair of standard length stainless steel flexible needles looped together with 96.5 cm length of 2-0 UHMWPE suture for easy inside out meniscal repair |