| 1 | TUBEWELL |
| 2 | Construction of tube well from ground level and up to 100 mtr. depth and above of following sizes in all types of soils in alluvium strata, unconsolidated formation such as pebbles, boulders etc. by \\"bailing\\" method and without gravel packing as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work includes formation of cavity at bottom by development with appropriate air compressor or bailer pumping and also lowering of casing pipe but excluding cost of the casing pipe. The tube well should have a throughout bore as per nominal dia of casing pipe. The work would be completed after obtaining sand free water. |
| 3 | Nominal bore 125 mm dia (PHED BSR 2023 ITEM NO. 2.5.1) |
| 4 | Nominal bore 150 mm dia (PHED BSR 2023 ITEM NO. 2.5.2) |
| 5 | Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. |
| 6 | Nominal bore 150 mm dia (PHED BSR 2023 ITEM NO. 2.4.1) |
| 7 | Nominal bore 200 mm dia (PHED BSR 2023 ITEM NO. 2.4.2) |
| 8 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes |
| 9 | 150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) (PHED BSR 2023 ITEM NO. 2.11.1) |
| 10 | 200 mm dia NB(Thickness of pipe 5.4 mm & mass of tube 28.46 Kg/m) (PHED BSR 2023 ITEM NO. 2.11.2) |
| 11 | HANDPUMP |
| 12 | Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe.(PHED BSR 2023 ITEM NO. 2.45) |
| 13 | Nominal bore 100 mm dia. (PHED BSR 2023 ITEM NO. 2.45.1) |
| 14 | Nominal bore 125 mm dia. (PHED BSR 2023 ITEM NO. 2.45.2) |
| 15 | Construction of tube well from ground level and up to 100 mtr. depth and above of following sizes in all types of soils in alluvium strata, unconsolidated formation such as pebbles, boulders etc. by bailing method and without gravel packing as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work includes formation of cavity at bottom by development with appropriate air compressor or bailer pumping and also lowering of casing pipe but excluding cost of the casing pipe. The tube well should have a throughout bore as per nominal dia of casing pipe. The work would be completed after obtaining sand free water.(PHED BSR 2023 ITEM NO. 2.46) |
| 16 | Nominal bore 100 mm dia. (PHED BSR 2023 ITEM NO. 2.46.1) |
| 17 | Nominal bore 125 mm dia. (PHED BSR 2023 ITEM NO. 2.46.2) |
| 18 | Supply of ERW M.S. black casing pipe ISI marked {IS:1239(Part-1:2004)} Mmedium of following sizes at site of work. |
| 19 | 100 mm dia NB( Thickness of pipe 4.5 mm & mass of tube 12.50 Kg/m) (PHED BSR 2023 ITEM NO. 2.47.1) |
| 20 | 125 mm dia NB( Thickness of pipe 4.8 mm & mass of tube 16.40 Kg/m) (PHED BSR 2023 ITEM NO. 2.47.2) |
| 21 | Supplying & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick mm wide shroud around the edge so as to form a cap on the top end of ng pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm es passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. |
| 22 | For 125 mm dia (PHDE BSR 2023 ITEM NO 2.23.1) |
| 23 | For 150 mm dia (PHDE BSR 2023 ITEM NO 2.23.2) |
| 24 | For 200 mm dia (PHDE BSR 2023 ITEM NO 2.23.3) |
| 25 | Supply and installation of ISI marked India Mark II Hand pump set complete with cylinder & 15 connecting rods. (PHED BSR 2023 ITEM NO. 2.51) |
| 26 | Supply & installation of GI pipe 32 mm medium class “B” with pipe sockets (heavy duty).(PHED BSR 2023 ITEM NO. 2.50) |
| 27 | Installation of India Mark II/III E.D. I & II hand pump set complete on existing platform..(PHED BSR 2023 ITEM NO. 2.54) |
| 28 | Construction of 185 cm. dia platform as per approved design & drawing of UNICEF.(PHED BSR 2023 ITEM NO. 2.55) |
| 29 | Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. |
| 30 | Up to 2.0 KW (PHED BSR 2023 ITEM NO. 2.14.1) |
| 31 | Above 2.0 KW (PHED BSR 2023 ITEM NO. 2.14.2) |
| 32 | SITC of Contactor OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 33 | 0.5 HP to 1.5 HP (DOL starter) (Pwd electrical BSR 2022 ITEM NO. 21.13.1.1) |
| 34 | 2.0 HP to 3.0 HP (DOL starter) (Pwd electrical BSR 2022 ITEM NO. 21.13.1.2) |
| 35 | Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended up to date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended up to date, along with clamping of submersible cable etc. complete in all respect.40 mm dia (PHED BSR 2023 ITEM NO. 2.25.1) |
| 36 | P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2.5 Sq.mm 3 core flat / Round (PWD electrical BSR 2022 ITEM NO. 4.7.2) |
| 37 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 3x 1.5 sq.mm (PWD electrical BSR 2022 ITEM NO. 4.1.3) |
| 38 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.(PHED BSR 2023 ITEM NO. 2.22) |
| 39 | Providing & Laying of Polypropylene rope Confirming to IS:5175 for submersible pump of following sizes. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 12mm (suitable up to 50 mm OD pipe) (Pwd electrical BSR 2022 ITEM NO. 21.3.1) |
| 40 | Providing and Fixing of ISI marked PVC storage tank of following capacity as ...S: 12701-1989 (of approved make) with cover, 25 mm dia. 1 mtr long ...overflow pipe, 25 cm long 25 mm dia washout GI pipe with plug & socket, ...ncluding P&F 32 mm dia Ball Cock (Float valve) IS 1703 marked with rod and ...PVC ball complete with brass weight 1000 gm, including P&F 15mm dia CI ...quarter turn heavy duty Bib Cocks four no's of superior quality and approved ...make, including interconnections complete job. |
| 41 | 1000 Liters Capacity (PHED BSR 2023 Item No. 2.28.1) |
| 42 | 2000 Liters Capacity (PHED BSR 2023 Item No. 2.28.1) |
| 43 | Fabrication & Fixing M.S. Stand of specified class of angle iron L-shaped of 50 mm size with four legs grouted by 300*300*300 mm CC Block M-15 in the ground and all legs tied up with each other through same size of angle iron along with cross bars to support the bottom of 1000 Ltr./ 2000 Ltr. PVC tank complete in all respect.(PHED BSR 2023 ITEM NO. 2.29) Please Enable Macros to View BoQ information |