|
| 1 | Antyeshti Yantra :- (A) Body M.S. Sheet Size 3mm & 2 mm angle structure 50x50x5 mm MS (B) Lining fire bricks alumina 70% with ceramics board thickness 50 mm capacity 1260 C (C) White heat castable (K) & accosset (50) for fire bricks fittings (D) Angle 65x65x10 & 35x5 SS 304 grade (E) Rod 30 mm 370 mm SS 304 grade (F) Pipe OD 40 mm thickness 5 mm SS 304 grade (G) Ceramic blanket (64D) total bolts & nut SS (H) Thermostat size 20mm OD x 450mm length (I) Control panel auto and manual both (J) Blower complete with fan size 305 mm with air controlled system (K) Motor 1 HP rpm 1440 (L) Chimni Length 3 meter size 350x350mm taper sheet thickness 3 mm ceramic board lining (M) Ceramics board fitting 50 mm and 25 mm (N) Both side SS door with lock size - 600 x 550 mm thickness 4 mm SS 304 grade 50 mm ceramic board and ceramic blanket (O) Sliding Trolly alignment bed angle size 50x50mm + 35x5mm + strip, length 4.5 meter Pipe size 75x75mm, 40x40mm & round 40mm ceramic board & ceramic blanket lining. (P) Sliding Trolly cover 1750 x 1180 x 440 mm sheet size 3 mm with roller Pipe size 75x75 mm, 40x40mm & round 40 mm ceramic board & ceramic blanket lining. (Q)Sliding Asthiya & Ash collecting Trey Size 2200 x 350 x 110 mm sheet thickness 3 mm with roller SS 304 grade (R) donator name plate size 600x406mm MS sheet (S) Coated with heat resistance paint with capacity of 600 degree silver color. |
| 2 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR.16.0 Sq. mm 4 core |
| 3 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 4 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 25 mm |
| 5 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR .Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating |
| 6 | Single pole MCB (With B/C curve tripping Characteristics)6 A to 32 A rating |
| 7 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure 'A' attached with this BSR . Short point (up to 3 mtr.) |
| 8 | Medium point (up to 6 mtr.) |
| 9 | Long point (up to 10 mtr.) |
| 10 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with High Power LED Flood Light Minimum lumen output 8700 lm |
| 11 | Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted complete with din rail making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Suitable for Two / Three / Four module for MCB. Please Enable Macros to View BoQ information |