| 1 | Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 2 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 3 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 4 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 300 sq mm |
| 5 | 3.5core x 185 sq mm |
| 6 | 3.5core x 150 sq mm |
| 7 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years 4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 8 | 6 Way(8+(4x3)+(3x6)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-18 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years |
| 9 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, single pole MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year.. |
| 10 | Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 11 | Supplying and fixing 63Amps 4P 415 volts MCB, C series , 10 kA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 year. |
| 12 | Supplying and fixing 63Amps 2P 240 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be Replacement Warranty will be 1 year |
| 13 | Supplying and fixing 40Amps 2P 240 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be Replacement Warranty will be 1 year |
| 14 | Supplying, installing on wall or suspension on ceiling, testingand commissioning of following capacity sandwichType Bus Trunking required for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-55 rating after fixing the tap off boxes and all accessories, made of 1.6mmthick steel sheet duly powder coated in convenient sectionscomplete with 4 Nos aluminium bus bars having currentdensity of 130 A/ sq cm at nominal current rating, necessaryjoints, elbow joints & expansion joints, fire barrier at each floor,continuous earthing with 2 Nos aluminium strip of 50x6mm(one on each side) including, G.I. clamping brackets,suspenders, angle iron bracket, steel fasteners, connecting toearthing system etc. as required.800A Isc = 50kA for 1 second 3P+N sandwich Al busbar with 2 nos 50x6 AL earth strip in complete as per the direction of engineer incharge . Make- Schneider/Siemens/Legrand/ABB |
| 15 | Supplying, installation, testing & commisioning of followingcapacity End Feed Unit for the existing sandwichType bus trunking/ rising mains for use on 3 phase 4 wire 415volts, 50Hz A.C. supply made with 1.6mm thick steel sheetenclosure (IP54) duly powder coated with provision ofMCCB/ACB complete with necessaryjoints including clamping brackets, angle iron bracket, steelfasteners, connecting to earthing system etc. as required.Make-Legrand/Schneider/Siemens/ABB800 A 50kA SC for 1 sec |
| 16 | Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing rising mains for use on 3 phase 4wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with MCCB ( complete etc. as required,as per the direction of Engg-in-charge completely Type Tested at NABL Accredited Laboratories as per latest IEC 61439 - 1&6 (Type Test Certificates must be submitted). Busbar to be insulated with multilayered Class F (155 Deg C) PET insulation.Warrentee period must be 1 year & compelete test certificate must be submitted .Make-Legrand/Schneider/Siemens/ABB315A 36kA SC for 1 sec |
| 17 | 200A 36kA SC for 1 sec |
| 18 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 19 | Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x300 sq mm |
| 20 | 3.5core x 185 sq mm |
| 21 | 3.5core x 150 sq mm |
| 22 | S/I/T&Commissioning of Main LT indoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 80X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 65 kA 3P+N type 1+2 SPD with 125 A 4P MCCB, TMR based, 25kA, Ics=100%Icu. Mandatory provision of cable alley is to be given. ON/OFF/TRIP indication shall be given for all the feeders. In commer-1- 01 number 4p 1600A EDO TYPE ACB with 1. Micro Processer Based with Breaking capacity - Icu= Ics= Icw= 50kA for 1 sec having LSING Protection with Display-Current Metering with Last Trip Record Data. (Communication with On & Off Status indication for Remote Closing and Opening operation of breakers through Modbus RS485 protocol and uploading breaker status to Users Computer/SCADA.) (Make-Schneider(Masterpact NW) / ABB (E max2)/ Siemens (3WT) /Legrand (DMX3). In commer-2- 01 number 4p 1600A EDO TYPE ACB with 1. Micro Processer Based with Breaking capacity - Icu= Ics= Icw= 50kA for 1 sec having LSING Protection with Display-Current Metering with Last Trip Record Data. (Communication with On & Off Status indication for Remote Closing and Opening operation of breakers through Modbus RS485 protocol and uploading breaker status to Users Computer/SCADA.) (Make-Schneider(Masterpact NW) / ABB (E max2)/ Siemens (3WT) /Legrand (DMX3). In commer-3- 01 number 4p 800A EDO TYPE ACB with 1. Micro Processer Based with Breaking capacity - Icu= Ics= Icw= 50kA for 1 sec having LSING Protection with Display-Current Metering with Last Trip Record Data. (Communication with On & Off Status indication for Remote Closing and Opening operation of breakers through Modbus RS485 protocol and uploading breaker status to Users Computer/SCADA.) (Make-Schneider(Masterpact NW) / ABB (E max2)/ Siemens (3WT) /Legrand (DMX3). In commer-4- 01 number 4p 800A EDO TYPE ACB with 1. Micro Processer Based with Breaking capacity - Icu= Ics= Icw= 50kA for 1 sec having LSING Protection with Display-Current Metering with Last Trip Record Data. (Communication with On & Off Status indication for Remote Closing and Opening operation of breakers through Modbus RS485 protocol and uploading breaker status to Users Computer/SCADA.) (Make-Schneider(Masterpact NW) / ABB (E max2)/ Siemens (3WT) /Legrand (DMX3).Buscoupler- 01 number 4p 1600A EDO TYPE ACB with 1. Micro Processer Based with Breaking capacity - Icu= Ics= Icw= 50kA for 1 sec having LSING Protection with Display-Current Metering with Last Trip Record Data. (Communication with On & Off Status indication for Remote Closing and Opening operation of breakers through Modbus RS485 protocol and uploading breaker status to Users Computer/SCADA.) (Make-Schneider(Masterpact NW) / ABB (E max2)/ Siemens (3WT) /Legrand (DMX3). Busbar- 04 numbers of 2000Amps aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. Out going- 04 numbers of 800A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS/ ABB Formula. Out going- 04 numbers of 400A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS/ ABB Formula, Out going- 04 numbers of 250A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS/ ABB Formula, Out going- 04 numbers of 100-63A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULA). Instrument- (i) 12 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 04 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data. 4 no. 3P+N 65kA type 1+2 SPD with125 A 4P MCCB, TMR based, 25kA, Ics=100%Icu.(Make of SPD-LEGRAND/ Siemens/ Schneider/ABB/OBO/DEHN) ( Make of MCCB -LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULA)(iii) All the MCCB outgoing feeders shall have digital ammeter with class 1 CT of suitable rating. Make-Legrand/ABB/Siemens/Schneider(iv) All the incoming and outgoing feeders shall have ON/OFF/TRIP indication. |
| 23 | FLOOR POWER PANELS/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 3P+N 40kA alongwith 63A, 4P MCB, 10kA, C series shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. Mandatory provision of Cable alley is to be provided. In commer - 01 no 250A 4P CHANGEOVER ,( Make-LEGRAND/ Siemens-/ Schneider-/ABB. Busbar-1&2 04 numbers of 400Amps AL busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing). Out going- 10 nos 63A 4P MCB 10kA,C series,415V for power BDB. (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB-SB 200) . Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication Make-Legrand/ABB/Schneider/Siemens. Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) Type 2 SPD 3P+N 40kA alongwith 63A, 4P MCB, 10kA, C series shall be installed in the incomer. Make of SPD-OBO/DEHN/ABB/Siemens/Schneider/Legrand Make of MCB- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB-SB 200 |
| 24 | FLOOR LIGHT PANELS/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 3P+N 40kA alongwith 63A, 4P MCB, 10kA, C series shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. Mandatory provision of Cable alley is to be provided. In commer - 01 no 200A 4P CHANGEOVER , (( Make-LEGRAND/ Siemens-/ Schneider-/ABB . Busbar- 04 numbers of 300Amps aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) . Out going- 10 nos 40A-63 4P MCB 10kA,C series Light load to LDBs . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200 . Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.. Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) Type 2 SPD 3P+N 40kA alongwith 63A, 4P MCB, 10kA, C series shall be installed in the incomer. Make of SPD-OBO/DEHN/ABB/Siemens/Schneider/Legrand Make of MCB- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB-SB 200 |
| 25 | FLOOR UPS PANELS/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 3P+N 40kA alongwith 63A, 4P MCB, 10kA, C series shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. Mandatory provision of Cable alley is to be provided. In commer - 01 no 125A 4P CHANGEOVER , (( Make-LEGRAND/ Siemens-/ Schneider-/ABB . Busbar- 04 numbers of 300Amps aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing). Out going- 10 nos 40A-63 4P MCB 10kA,C series Light load to LDBs . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200, Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) Type 2 SPD 3P+N 40kA alongwith 63A, 4P MCB, 10kA, C series shall be installed in the incomer. Make of SPD-OBO/DEHN/ABB/Siemens/Schneider/Legrand Make of MCB- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB-SB 200 |
| 26 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(4X6+2X4) |
| 27 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI /V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(4X10+2X6) |
| 28 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE-Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. Please Enable Macros to View BoQ information |