| 1 | Item Description/ Heading |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 4 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 5 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design& shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 6 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 7 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | ASPHALTBASCOur Scope:(1) Excavate the surface to creates open of 1 for every 10' on shorter as(2) Compaction of Such Base with 8-10 tonne roller(3) Anti Termite and Weed Growth: Carry out anti termite and weedicide on the total area by applying chemicals and spraying(4) Wet Mix Macadam-150mm Providing and laying of compacted 150mm thickness of WMM in one layer as per specifications and drying up and cleaning the surface.(5) Ruling to be done in both Wet and Dry phases of WMM,(6) Primer coat Providing & applying primer coat over prepared surface or granular base with bitumen emulsion as per 15: BBET & manufacture's specification @6kg./10 Sqm. With a self-propelled or towed bitumen pressure sprayer equipped for spraying the material uniformly at specified rates & temperatures.(7) BITUMINOUS MACADAM (Bitumen 3.50% by weight) Lay a 35mm compacted thick Hot Mix asphalt BM coarse using mix of 20 mm and 12 mm stone with 60-70 Grade Bitumen.(8) The compaction of BM layer to be done using road roller of capacity 8-10 ton(9) Tack coat Providing & applying tack coat on the prepared surface, with bitumen emulsion as per 15: 8887 and manufacture's specification@2kg/10 Sqm. With a self-propelled or towed bitumen pressure sprayer equipped for spraying the material uniformly at specified rates and temperatures.(10) ASPHALTIC CONCRETE (Bitumen by weight) Lay a 25mm compacted thick Hot Mix AC coarse using 6mm stone/Baby chips (Mixture of 0-6mm stones devoid of dust) mixed with 60-70 Grade Bitumen.(11) The compaction of AC layer to be done using road roller of capacity 8-10 ton;SEAL DUST Seal dust to be spread to cover all the voids using stone dust with Bitumen to make the surface appropriate for synthetic installation Cold rolling to Be done immediately next day of applying seal coat in the early morning hours when the climate is cold as compared to rest part of the day |
| 10 | Providing and laying European standards ITF certified 8 layers acrylic synthetic standards system with thickness upto 3mm 1 layer of acrylic primer 2 layers of acrylic resurfacer 3 layers of acrylic cushion 2 layers of colour coat Line markings as per international standards. |
| 11 | Providing and installation of International Standards Fixed Type Tennis Post 1. Technical Specifications: This Model confirming to the international Standards with heavy-duty structural frames & proper reinforcement. Tennis post made will 4\\" MS Square Pipe with special internal retched system for tightening the rope/net. Post shall be epoxy Painted and Net to be approved by ITF. (1 set = 2 poles + net, Net with fixing accessories of complete set.) |
| 12 | Supply of ANTIGLARE LED FLOOD LIGHT for Tennis Court Part No: - MAX - 200W - Power: 200W - IP Rating: IP 66 - Operating Voltage: 110 V to 300 VAC (50Hz) - LED: BRIDGE LUX - LED Efficacy: 150 lm/W (+/-5%) - Colour: Cool White - Colour Temperature: 5500K to 6500K - Beam Angle: 120 Deg. LENS |
| 13 | Supply Of 6 mtr Mast Pole with Open Ladder (Steps) - Suitable For 2/4 Nos of 200W Luminary Mounting Structure. - Suitable for Foundation Bolts for 6 mtr. pole. |
| 14 | Supply of Control Panel, Cables, MCBs and other accessories: 1. Pole Control Panel near the pole. 2. Terminal Block / Bus-bar 3. 2.5 sqmm 3 core Copper Cable for connection between pole control Panel and Luminaries 4. MCB Protection for each Light 5. Incomer MCB - 1 No. |
| 15 | Master Control Panel with - Incomer MCB: 1 No. - Outgoing MCB: 4 Nos. - Other accessories - 6 sqmm 4C Aluminium Armoured Power Cable - 220m Note: Supply of cable and Laying of the cable from the Grid source of power to the Main control panel will be provided by the customer. |
| 16 | 1. Grouting (Foundation and Civil work including materials) 2. Grouting of the Control panels. 3. Earthing Pit for panels. |
| 17 | Erection and commissioning of the System - It includes: 1. Erection of the Light 2. Installation of Lights 3. Cabling to all lights 4. Adjustment of Lights 5. Control Panel Installation 6. Commissioning |
| 18 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 19 | Trimming trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Above 240 cm girth. |
| 20 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes |
| 21 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |