| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 4 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources). |
| 5 | Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 7 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 8 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. |
| 9 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement |
| 10 | All works above plinth level upto floor V level |
| 11 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 13 | Suspended floors, roofs, landings, balconies and access platform |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 16 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 18 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 19 | 12 mm cement plaster of mix : |
| 20 | 1:4 (1 cement: 4 fine sand) |
| 21 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 22 | 1:4 (1 cement: 4 coarse sand) |
| 23 | 6 mm cement plaster of mix : |
| 24 | 1:3 (1 cement: 3 fine sand) |
| 25 | White washing with lime to give an even shade: |
| 26 | New work (three or more coats) |
| 27 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : |
| 28 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 29 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 30 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 31 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 32 | 80x1.25 mm M.S. laths with 1.25 mm thick top cover. |
| 33 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 34 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 35 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings, glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). |
| 36 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 37 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 38 | Fixed to steel windows by welding |
| 39 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : |
| 40 | 4.0 mm thick glass panes. |
| 41 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 42 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120mm and minimum thickness at khurra as 65 mm. |
| 43 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.A) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 44 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. |
| 45 | Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 : |
| 46 | 200 mm dia Ductile Iron Class K-9 pipes |
| 47 | Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and the cost of rubber gasket : |
| 48 | 200 mm dia pipes |
| 49 | Providing and laying D.I. specials of class K-12 suitable for push-on jointing as per IS : 9523 : |
| 50 | Up to 600 mm dia |
| 51 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 52 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 53 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :- |
| 54 | 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 55 | b)1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 56 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 57 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 58 | Desiting of water body by taking out silt, sludge, plastic bags floating material, patera etc i/c working in foul condition by mechanical means by hydraulic excavator having boom length not less than 15m including disposal of taking out silt with in a lead upto 50m and lift upto 1.5 m etc . All complete as per the direction of Engineer-in-charge. |
| 59 | All kinds of soil |
| 60 | Disposal of manure/sludge by mechanical means including loading, transporting, unloading for lead upto 2 Km as per the direction of Engineer-in-charge. |
| 61 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift upto1.5 m. |
| 62 | All kinds of soil. |
| 63 | Total= 60,24,974.08 |
| 64 | Add GST correction factor @0.973 =58,62,299.78 |
| 65 | Add CI @ 4.03% |
| 66 | Total of Civil works =60,98,550.00 A |
| 67 | ELECTRICAL WORK |
| 68 | Running , maintenance & operation of non-clog submersible sewage pump sets i/c area lighting & allied E&M works at p/house at Ghevra water body-1&2 as per terms and conditions attached with deployment of following labour:-Wireman cum Operator Gr-II-1 No. in General shift i.e from 6.00 a.m to 2.00 p.m.,from 2.00 p.m. to 10.00 p.m. and from 10.000 p.m. to 6.00 a.m. or as and when required. |
| 69 | Providing,installation, testing & commissioning of non-clog submersible sewage pumpset suitable for operation on 415 volts, three phase, 50c/s AC supply and having under noted specifications i/c discharge elbow,cabling etc. complete as required as per approval from the Engineer-In-Charge:- a) Discharge 500 m3 per hr. b) Head range 10 mtrsc) No of stages 8 Nos d) Motor rating 24 kwe) Pump outlet 65 mm f) IP Protection: IP-68g)Pump Casing: C.I. h)Impeller : CF8Mi)Shaft: CrSt. j)atleast Max. solid handling capacity: 80 mm |
| 70 | Supplying, installation, testing and commissioning of hot dip galvanized octagonal steel pole of 9 Mtr. height and made of 3 mm thick sheet, having bottom 155 mm OAF & top 70 mm OAF, hot dip galvanized M.S base plate of size 260 mm x 260 mm x 16 mm thick, on existing RCC foundation with GI bolt and nuts, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking/ numbering of pole etc. complete as per drawing & technical specifications attached including following accessories with mounted inbuilt control box having flush cover with 2 nos mounting strips with tapped holes:- (a) 6 mm thick phenolic laminated / bakelite sheet inside the window mounted on the existing mounting strips inside the flush door. (b) 4 nos. 40 Amp terminal block suitable for following conductor / cable, fixed on DIN channels i/c providing and fixing DIN channel of suitable length – on the existing phenolic laminated / bakelite sheet. (i) 16 sq mm conductor – 4 nos and short links 5-nos. (ii)Terminal suitable for 6 SWG GI wire / 1.5 sq mm wire. (c) 6 Amp SP MCB,10 kA ‘C’ Series-1 nos. including mountings on DIN channel, Earth stud 2 Nos. welded at suitable height i/c washers, springs washers & nuts etc. (d) Suitable arrangement for saddling of incoming / outgoing cables i/c lugs thimbles etc as required. |
| 71 | Providing and laying in position, M25 reinforced cement concrete foundation of size 500mm long x 500mm wide and 1400 mm deep i/c excavation of earth, refilling, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia. 1500 mm long (approx.)-8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia. 2000 mm long (approx.)-8 Nos. (With approx. 150 mm spacing) i/c centering & shuttering as required, positioning of foundation bolts 4 nos. M-24x750mm long foundation bolt of L Type (100 mm bend & 750 mm straight), 150 mm top threaded portion of bolt shall be galvanized and rest portion shall be coated with Red oxide to avoid corrosion & G.I nuts (EN 8-grade) with 3 Nos. and 2 Nos. washer, along with 2 Nos. templates/Anchor plate of size 260 mm x 260 mm x 3 mm thick shall be supplied manufactured from the original pole manufacturing company only for casting of foundations and providing 63 mm (OD) 2 Nos. DWC pipe 1 mtr long approx. each for cable entry and exit etc complete as required. |
| 72 | Supplying and installation of hot dip galvanized circular ring having inner diameter 1000 mm made out of 48 mm dia MS pipe B-class and having 4 nos. arms of length approximate 400mm long each made out of 40mm dia MS pipe B- class i/c mounting arrangement at the top of the pole i/c marking holes for installation of flood light luminaries and wire entries with movable cap at the top with fixing arrangement. Complete as required. |
| 73 | 100 W LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15,lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg, suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 74 | Providing, installation, testing and commissioningof non-return valve (double flanged) of following sizesconfirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required |
| 75 | 65 mm dia |
| 76 | CONTROL PANEL (Common for 2 Nos pumps) |
| 77 | Providding,installation, testing & commissioning of CRCA sheet floor mounting type cubicle pattern control panel suitable for indoor installation and consisting of following :The specification of incoming and outgoing shall be as under:- Incoming 1 No.MCCB-160 A 1No. Voltmeter(0-500 V)1No. Voltmeter selector switch1 Set Phase indicating lamps1 No. Ammeter-1No Bus Bar -160 AOutgoing consisting of 5 No. Star Delta starter starter (22Acontractors & Relay(9-14A)) 5 No Single phase preventor cum reverse rotation 5 No MCB-32 A 5 No Ammeter(0-30A) 5 No Voltmeter(0-500 V) 5 No Star delta timer 5 No Auto phase corrector unit(Karsan) etc. complete as required. |
| 78 | Supplying & fixing of submersible flat copper conductor cable of size 3C X 4 sq. mm. with voltage grade 1100 KV i/c testing & commissioning etc. complete as required. |
| 79 | Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts,bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :65 mm |
| 80 | Supply of 3.5 C x 25 sq. mm. size of 1.1 KV grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable as per IS : 7098:1988 with upto date amendments. |
| 81 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 82 | Supplying of following sizes of PVC insulated and PVC sheathed/XLPE aluminium conductor armoured power cable of 1.1 KV grade i/c connection & testing etc. as required and as per technical specification enclosed. |
| 83 | 4 x 16 Sq.mm |
| 84 | 4 x 25 Sq.mm |
| 85 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 86 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 87 | Laying of one number PVC insulated and PVC sheeted/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/Metal/DWC pipe / pole as required. |
| 88 | Up to 35 Sq.mm |
| 89 | Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 90 | 3.5 C x 25 sq. mm. |
| 91 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductorsingle core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.. Group C |
| 92 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in recessed steel/ PVC conduit as required. the existing surface |
| 93 | 3 x 1.5 sq. mm |
| 94 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required. |
| 95 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 96 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 97 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 98 | 25 mm |
| 99 | Supply of energy efficient Metallic body exhaust fan of 300 mm sweep with minimum air delivery of minimum 1000 cubic meter per hour at rated RPM to operate on single phase 230 volt, 50 HZ AC Supply with 3 Nos. Aerodynamically designed & Balanced Blade/impeller, copper winding with bird guard to protect the fan in running condition, arm-set, frame and all required accessories, Installing the exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 100 | Supply, Installation, Testing and Commissioning of 1200 mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9,Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as reqd. |
| 101 | Supplying of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) 18W-22W LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 102 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 103 | Single pole |
| 104 | Double pole |
| 105 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 106 | Supplying & fixing following way, single pole & neutral, sheet steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing testing & commissioning etc. as required.(But without MCB/RCCB/Isolator) |
| 107 | 8 way , Double door |
| 108 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 109 | 5/6 A switch |
| 110 | 15/16 A switch |
| 111 | 3 pin 5/6 A socket outlet |
| 112 | 6 pin 15/16 A socket outlet |
| 113 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 114 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 115 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Please Enable Macros to View BoQ information |