| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group A |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 3 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | 2 X 6sq. mm + 1 X 6 sq. mm earth wire |
| 5 | 4 X 10sq. mm + 2 X6 sq. mm earth wire |
| 6 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 7 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.1 x 1.5 sq. mm |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 9 | 15/16 A switch |
| 10 | 3 pin 5/6 A socket outlet |
| 11 | 6 pin 15/16 A socket outlet |
| 12 | Installation, Testing and Commissioning of pre-wired,fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required |
| 13 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.300-450 mm sweep |
| 14 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way , Double door |
| 15 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 16 | Single pole and neutral |
| 17 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 18 | Supplying and fixing batten/angle holder including connection etc. as required. |
| 19 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door |
| 20 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 21 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 22 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 23 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 A,30KA,FPMCCB |
| 24 | Supplying of following type and watt LED light including necessarry connection wires etc as required.a)18-20 Watt LED batten light |
| 25 | b)9 Watt LED Bulb |
| 26 | Supplying and fixing 400 mm sweep Wall fan with all necessary connections and materials required etc. |
| 27 | Supplying and fixing following size/ modules, PVC box alongwith cover plate for modular switches etc. as required a)6Module |
| 28 | b)3 Module |
| 29 | Supply of following sizes of single phase 240 volts heavy duty exhaust fan complete with including all accessories as required. 450mm dia, 900 RPM. |
| 30 | Supplying of 2.5 mfd capacitor including connection in the exisiting ceiling fan complete |
| 31 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.TPN MCB 63 amps |
| 32 | Supply of following sizes of single phase 240 volts heavy duty exhaust fan complete with including all accessories as required. 300mm dia |
| 33 | Supplying and fixing following Size, tin copper busbar as required.and as approved by the deptt. 200 Amps |
| 34 | Supplying and fixing following rating and pole, MCCB enclosure in the wall as directed and approved by the deptt 125 Amps four pole |
| 35 | Providing and fixing 8 SWG dia G.I. wire on surface or in recess forloop earthing as required. |
| 36 | Dismantling of existing wiring system where necessarry including disconnection of every equipments etc and depositing the materials in a specified location as directed by the department |
| 37 | Supplying and fixing following rating,SPN , 240 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 Amps Please Enable Macros to View BoQ information |