| 1 | Supplying and laying of following 3.5X50 sqmm one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade, aluminium conductor,armoured underground cable as per IS 7098 (Part-I) 1988 with upto date ammendments of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering (Make:Havells/Polycab/Fenolex/L&T/RR Cabal make) |
| 2 | Supplying and laying of 3.5X50 sqmm PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade, aluminium conductor, armoured cable as per IS 7098 (Part-I) 1988 with upto date ammendments. 3.5X50Sq mm size in the existing RCC/ HUME/METAL pipe/In air as required. (Make:Havells/Polycab/FInolex/L&T/RR Cabal make) |
| 3 | Providing and fixing of Switch Disconnector Fuse Open Execution (QSA - Series) Conforms to IS-13947 - Part I & III / IEC-947 Part I & III, AC-23A, 415V, 50 Hz, 100Amps. Rating, in the existing panel connection testing and commissioning etc as required. (Make: HPL/Havells/Legrand/ABB/Anchor/L&T/Schneider make) |
| 4 | Providing and fixing of Switch Disconnector Fuse Open Execution (QSA - Series) Conforms to IS-13947 - Part I & III / IEC-947 Part I & III, AC-23A, 415V, 50 Hz, 250Amps. Rating, in the existing panel connection testing and commissioning etc as required. (Make: HPL/Havells/Legrand/ABB/Anchor/L&T/Schneider make) |
| 5 | Repairing of existing complete meter box panel having set of 04 Nos Qtrs each, cleaning, removing of existing burn/defective cables, dismantling of existing switches, priming and painting of panel, fixing of panel cover connection of existing cables, repairing of existing cable connection including connection of incoming cable and outgoing submain etc. as required. |
| 6 | Repairing of existing out-door panel cleaning, removing of existing switches, burn/defective cables, excavation of nearly panel and to check the Loop i/c Providing and fixing of back side MS Sheet cover 2.0 mm thick size 1.0 Sqm suitable for existing panel, priming and painting of panel, connection of existing cables after repairing etc. as required. |
| 7 | Supplying and laying of 3.5X35 sqmm PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade, aluminium conductor, armoured cable as per IS 7098 (Part-I) 1988 with upto date ammendments. 3.5X50Sq mm size in the existing RCC/ HUME/METAL pipe/In air as required. (Make:Havells/Polycab/Finolex/L&T/RR Cable make) |
| 8 | Supplying and laying of 3.5X120 sqmm PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade, aluminium conductor, armoured cable as per IS 7098 (Part-I) 1988 with upto date ammendments. 3.5X50Sq mm size in the existing RCC/ HUME/METAL pipe/In air as required. (Make:Havells/Polycab/Finolex/L&T/RR Cabal make) |
| 9 | Providing and fixing of Single Phase kWh meter two wire static electronic meter with LCD display, 1P LCD Meter 5-30A, Fixing in the existing panel connection etc. as required. (Make : Cat. No. L&T/Seimens/HPL Make) |
| 10 | Providing and fixing of TPN MCB 'C' Curve 63Amp. Fixing in the existing panel connection etc. as required. (Make : Cat. No. Havells/Schneider/L&T/ABB/BCH/C&S Make) |
| 11 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Single pole and neutral (Make Havells/L&T/Legrand/ABB/BCH/C&S) |
| 12 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm |
| 13 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm Please Enable Macros to View BoQ information |