Tender For Replacement Of Pumping Machinery Of Iph Sub Division Chandi In Gp Chandi In Tehsil Kasauli District Solan (Hp) (Sh: Supply Erection Of Centrifugal Pump Alongwith Allied Accessories To Be Coupled With Existing Motor 25 Hp At Lwss Anji Manes, Solan-Himachal Pradesh
TDR : 56096951
Tender Notice
BOQ
7 Days Left
Solan
Himachal Pradesh
Tender For Replacement Of Pumping Machinery Of Iph Sub Division Chandi In Gp Chandi In Tehsil Kasauli District Solan (Hp) (Sh: supply erection Of Centrifugal Pump Alongwith Allied Accessories To Be Coupled With Existing Motor 25 Hp At Lwss Anji Manes
Name of Work:- Replacement of pumping machinery of IPH Sub Division Chandi in GP Chandi in Tehsil Kasauli District Solan (HP) (SH: S/E of centrifugal pump alongwith allied accessories to be coupled with existing motor 25 HP at LWSS Anji Maneshi 1st stage) (Under PDNA).
Sl. No.
Item Description
1
Providing Installation i/c testing and commissioning at site horizontal spindle horizontal split casing/end suctions (back full out arrangement) single/double/ multistage centrifugal pump or combination of pump in series of recommended make such as Mather and Platt/ KSB/ Kirloskar /Becon weir/BE/Jyoti as per IS-1520-1980 / IS 5659 - 1970 with up to date amendments, read with IS: 9137-1978 or latest edition suitable for lifting clear / raw water for under mentioned characteristics with bronze impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be from the manufacturers of the pumping unit only) to Squirrel Cage / Slipring drip proof induction motor of standard make such as Kirloskar /Crompton /Bhel/NGEF/GEC/Siemen/Jyoti/ABB and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be at least 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 25% of the duty point head. The motor should be as per IS: 325-1978 with up to date amendments read with IS: 900-1972. It should include cost of bearing nuts, bolts and pointing etc. and should meet the following requirements:-
2
Discharge (Q) : - 4.170 LPS (15 Hour)
3
Total dynamic head : 185 mtrs.
4
(a) LWL in sump well (h) :
5
(b) Shaft level :
6
(c ) Level at discahrge point :
7
(d) Suction lift :
8
(e) Residual head :
9
(f) Static head :
10
(i) Rising Main :
11
(a) Length:- 930 Mtrs
12
(b) Dia. :65 mm
13
(iv) Pumping Hours : 8 Hours.
14
Altitude of installation above MSL:-
15
Characteristic of Water
16
Temperature:-
17
Ambient
18
Alkalinity :- Mg/CaCo3
19
Size of the Solids (mm)
20
Other Please Enable Macros to View BoQ information