Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56096384

Tender For Demolition And Construction Of Mes Ib At Shahjahanpur Cantt Under Ge (East) Bareilly

Issued by Statutory Bodies & Commissions/Committees · Shahjahanpur, Uttar Pradesh
Tender Value
1.97 Crore
Estimated cost
Bid Submission
06 Aug 2026
16 days left
EMD
2.72 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Shahjahanpur → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Demolition And Construction Of Mes Ib At Shahjahanpur Cantt Under Ge (East) Bareilly

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 10-Jul-2026 BOQ revised BOQ 20-Jul-2026
2 10-Jul-2026 Critical Dates extended Date 28-Jul-2026
3 10-Jul-2026 BOQ revised BOQ 28-Jul-2026
4 16-Jul-2026 Critical Dates extended again Date 06-Aug-2026
5 16-Jul-2026 List of Drgs and Drgs inserted Other 06-Aug-2026
6 10-Jul-2026 Critical Dates extended Date 28-Jul-2026
7 10-Jul-2026 BOQ revised BOQ 06-Aug-2026

BOQ

Name of Work:- DEMOLITION AND CONSTRUCTION OF MES IB AT SHAHJAHANPUR CANTT UNDER GE (EAST) BAREILLY
Sl. No. Item Description
1SCHEDULE A PART-I (BUILDING WORK)
2Construction of MES IB complete all as specified and as shown of drawing
3Construction of servant quarters for MES IB complete all as specified and as shown of drawing
4Construction of garages for MES IB complete all as specified and as shown of drawing
5SCHEDULE A PART II (INTERNAL WATER SUPPLY) for details refer Sch A in pdf folder
6SCHEDULE A PART III A (INTERNAL ELECTRIC SUPPLY) for details refer pdf folder
7SCHEDULE A PART III B (EXTERNAL ELECTRIFICATION)
8S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder includingLED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. with suitable size complete all as specified and directed.
9S&F buildig security light fitting energy saving LED light fitting 45 watt made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK07 as reqd to be mounting bracket in wall/floor to suit the opening of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection complete all as specified and directed.
10M&L for GI Bracket made out of 25 mm GI Pipe light grade 1.20 m length bend to shape including clamps, nuts bolt and washer and fixing to wall/ floor complete all as specified and directed.
11SCHEDULE A PART IV (EXTERNAL WATER SUPPLY) for details refer pdf folder
12SCHEDULE A PART V A (EXTERNAL ELECTRIFICATION) for details refer pdf folder
13SCHEDULE A PART V B (EXTERNAL ELECTRIFICATION)
14S&F in replacement of unserviceable Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete all as specified and directed.
15S&F mounting bracket made out of medium grade GI tubing suitable size bent to shape including 02 Nos MS clamps, Nut bolts, washers etc complete all as specified and directed.
16S&F FRP junction box for suitable bus bar rating and 10 amp MCB for control of security light as per nut bolt washer etc complete all as specified and directed.
17M&L for supply, installing, testing & commissioning of factory made LT panel outdoor type for LT distribution switch gear and control gear,floor mounted ,cubical type modular compartment, dust and vermin proof with neoprene gasket fabricated out of CRCA sheet of thick ness not less than 3.15 mm (CPRI Approved) complete with bus bar chamber & Cupper Bus bar of four wire system 415 volt with heat shrinkable insulator sleeve suitable for 200 A for phases and for neutral having openable front and rear shutters with suitable locking arrangement epoxy powder spray painted with one coat primercomplete including PCC 1:2:4 type B-1 using 20 mm graded stone agregate foundation raised base angle iron size 50mm x50mmx6mm thick 60cm up and 60cm ground level complete all as specified and directed of the following components:-
18(a) Supply and fix 4 Pole Change over ,100 Amp 50 Hz 415 V, With Thermal based Release type Capacity 25 KA complete all as specified and directed =01 Nos(b) INCOMING :- (i) Supply and fix 4 Pole MCCB ,100 Amp 50 Hz 415 V, With Thermal based Release type Capacity 25 KA complete all as specified and directed =01 Nos(c) OUTGOING :- (ii) Supply and fix 4 Pole MCCB ,63 Amp 50 Hz 415 V, With Thermal based Release type Capacity 25 KA complete all as specified and directed =03 Nos(c) Supply and fix SPN MCB ,20 Amp 50 Hz 415 V, With Thermal based Release type Capacity 25 KA complete all as specified and directed =01 Nos
19(d) Supply and fix R Y B Phase LED based indicator lamp sets comprising of three colours complete all as specified and directed =01 set(e). Ammeter 0 - 400 Amps, Digital display, flush mounted 3 phase 4 wire with slector switch including CTs of required capacity =01 Set(f) Voltmeter 0 - 600 Volts, Digital display, flush mounted 3 phase 4 wire with slector switch - 01 set.(g) complete Internal wiring of suitable size of copper wire.(h) Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure.
20SCHEDULE A PART VI A (AIR CONDITIONING) for details refer pdf folder
21SCHEDULE A PART VI B (AIR CONDITIONING)
22S&F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA complete all as specified and directed.
23SCHEDULE A PART VII A (WATER HEATER) for details refer pdf folder
24SCHEDULE A PART VII B (WATER HEATER)
25S&F plug 16 A (Plug top) indicitor complete all as specified and directed.
26SCHEDULE A PART VIII A (WATER COOLER AND REFRIGERATOR) for details refer pdf folder
27SCHEDULE A PART VIII B (WATER COOLER AND REFRIGERATOR)
28S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1KVA complete all as specified and directed.
29S&F refrigirator elect driven single phase double door cap uo to 300 ltr, 240 volts 50 HZ of ,suitable inbuilt voltage stablizers fully automatic inverter type BEE 3 star rating complete all as specified and directed.
30SCHEDULE A PART IX (FENCING, COMPOUND WALL AND GATE) for details refer pdf folder
31SCHEDULE A PART X (AREA DRAINAGE) for details refer pdf folder
32SCHEDULE A PART XI A (SEWAGE DISPOSAL) for details refer pdf folder
33SCHEDULE A PART XI B (SEWAGE DISPOSAL)
34Supply, laying and testing of 150 mm inner diameter of double wall corrugated (DWC) high density polethelene pipes(HDPE) and stiffness class-8 (SN-8) with ISI marked (with CML No) with and including all fittings & jointing materials for sewage line and laid in trenches as specified in IS-16098(Part-2):2013 and as per manufacturer's instruction complete all as specified and directed. Note:- Bedding of pipe shall not be provided in normal condition and construction methods shall be strictly compiled as per clause no A-4 Annex 'A' of IS 16098(Part-2):2013
35S&F factory made SFRC MH cover with frame confirming to IS 12592:2002 HD 20 grade, of size 750mm circular or 750 x 750 mm rectangular sorrounded with steel strip 50 x 1.5 mm reinforced shall be as per relevant IS and laid over man hole brick work or concrete in CM 1:4, including reinforcement, complete all as specified and directed. Notes: - (i) Contractor shall provide PV alongwith manufacturer test certificate of SFRC cover. (ii) Reinforcement shall not be measured and paid seperately.
36M & L for on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for.
37M & L for Soakage wells excavation, in any type of soil,foundation in PCC 1:3:6,walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size of 3.0 M dia × 3.0 M effective depth complete all as shown on Drg No TD-309 1/4 to 4/4.
38SCHEDULE A PART XII A (ROAD/ PATH/ CULVERT) for details refer pdf folder
39SCHEDULE A PART XII B (ROAD/ PATH/ CULVERT)
40Supply and laying hume pipe culvert with & using hume pipe 450 mm bored dia of pipe class NP-3 and 6 mtr long laid over concrete bed and job jointed with coping & rendering complete all as specified and directed.
41SCHEDULE A PART XIII (DEMOLITION & DISMANTLING) for details refer pdf folder
42SCHEDULE A PART XIV (SITE CLEARANCE) for details refer pdf folder
43SCHEDULE A PART-XV (ARBORICULTURE)
44Supply and planting the following trees/ plants/ Hedges/ Shrubs in the location as directed by Engr-in-Charge including preparing compost pit of size 60 cm x 60cm x 60 cm deep by excavation in ordinary soil including removal of surplus soil upto 100 meters an dapplying suitable anti termite treatment and filling with garden earthe manure and neem cake.(i) The rate for excavation and getting out of soil shall be deemed to be included in the unit rate of this item.(ii) The rate for mixing earth, manure and sand deemed to be included in the unit rate of this item.(iii) The rate of items included supply and application of Neem Cake and ATT chemical.(iv) Height of plant shall be measured from top of follage and not the isolated branch/leaf main stem and measured upto 150mm from top of roots.(v) The rate shall also include regular watering to the plants till satisfactorily growth and replacement of dried plant.
45(a) German bottle Palm tree height 1.50 m plus, girth 6 cm to 8 cm pit size (0.90 m x 0.90 m x 0.90m)
46(b) Planting the Hedges of required size and type complete pits size will be 20cm x 20cm x20 cm
47Preparing Lawn including excavating the ground to required depth of 30 cm removing and coveying unwayed stuff too a distance (upto 50 Mtr) as directed and Providing & filling fresh garden soil and manure throughly well, levelling, watering on previous night, including planting required (Bermuda or as approved by Engineer-in-Charge) variety of lawn grass as directed and mainting till well established by watering, weeding, clipping, roliing etc complete.
48Maintenance of all plants, shrubs, hedges grass from date of completion with employing 2 (two) skilled Gardener per day to ensure healing upkeep/watering of plants, pour manure, carrying out periodic tilling and use pesticized cutting grass and removing unwanted grass and plants at work site as per requirement and directed by Engr-in-Charge.(i) During the maintenance of the day plant, shrub, grass etc is found dead, not true to the name or size as specified or not in satisfactory growth plant of approved size and snap shall be replaced by contractor without any extra cost.(ii) If contractor failed to comply, above the work will be carried out through agency and the amount will be recovered from final bill.(iii) Supply and application of measure, sweet earth, sand, ATT chemical and pesticides, fertilizers, cartageas required etc are included in quoted unit rate during maintenace period.(iv) Commencement of maintenance period will only count after satisfactory completion of Phase-I as above.(v) If water is not available contractor has to bring water from outside and nothing extra will be paid on this account.(vi) Cost of hose pipe required for watering will be borne by the contractor. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56096384
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.97 Crore
LAST DATE 06-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Demolition And Construction Of Mes Ib At Shahjahanpur Cantt Under Ge (East) Bareilly
Basic Detail
Tender No 8200/B/955/E8
Bidding Type Tender
Location
City Shahjahanpur
State Uttar Pradesh
Key Dates
Publish Date 16 Jul 2026
Submission Date 06 Aug 2026
Open Date 13 Aug 2026
Finance
Tender Value 1.97 Crore
Tender Fee 1000
EMD 2.72 Lakhs
Exemption Available
Document List
1DrgsIB.pdf
BOQ_866429.xls
e53830d7-ea7c-40eb-803c-9d24bcb4a43b.html
PS_68.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 28, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Jul 28, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Aug 06, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 16 days
Aug 06, 2026
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 16 days
Jul 28, 2026
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Aug 06, 2026
18:00 IST

Corrigendum-7 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 16 days
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Aug 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
pdf

1DrgsIB.pdf

xls

BOQ_866429.xls

html

e53830d7-ea7c-40eb-803c-9d24bcb4a43b.html

pdf

PS_68.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders