Defence Statutory Bodies & Commissions/Committees Closing in 3 days TDR #56096383

Tender For Repair/Maint Of Or Cook House And Dining Hall Of Bldg No. T-193 A At Si Lines Under Ge Bhopal

Issued by Statutory Bodies & Commissions/Committees · Bhopal, Madhya Pradesh
Tender Value
25.47 Lakhs
Estimated cost
Bid Submission
18 Jul 2026
3 days left
EMD
51000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Or Cook House And Dining Hall Of Bldg No. T-193 A At Si Lines Under Ge Bhopal

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 11-Jul-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-Jul-2026

BOQ

Name of Work:- REPAIR/MAINT OF OR COOK HOUSE AND DINING HALL OF BLDG NO. T-193 A AT SI LINES UNDER GE BHOPAL
Sl. No. Item Description
1Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline
2Supply & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) with 12mm semi perforated micro tegular edges GRG false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000 mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws complete all as specified and directed.
3Dismantling wall and ceiling boards(fibre, pulp,insultion, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed
4S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick (precoated AZ 150 micron) of approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and bitumen washer fixed at any location complete all as specified and directed
5All as per item here-in-before 3.00 but plain sheeting, in ridges completed all as specified and directed.
6Dismantling stone slab and tiles of any description and thickness as in floor including cement mortar bedding and rubbish off the premisses complete all as specified and directed.
7Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubish of the premisses complete all as specified and directed.
8M&L machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 15 mm thick screed bed in cement mortar 1:4 complete including dismantiling all as specified and directed.
9M&L for light shade, vitrified ceramic tiles 9-10 mm thick, premium quality, coloured (of approved shade and design) area of each tiles exceeding 0.42sqm but not exceeding 1.00 sqm, joint free, as in floors and skirting etc. set and jointed in neat cement slurry and joints grouted with pigment to match with shade, laid over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
10M&L for approved colour & shade virified ceramic tiles 9-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors and skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 all as specified and directed.
11M&L glazed ceramic colour tiles with suitable matching highlighter in vertical surfaces of size not less than 450x 300x 7-8mm thick set and jointed in neat cement slurry fixed over and including 10mm thick rendering in CM (1:4) as in backing coat and pointed in white or colour cement to match the shade of tiles including dismantling of old tiling fixed in any mortar and position complete all as specified and directed.
12M&L green marble (approved pattern and texture) work 15 to 18mm thick (table rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and like in laid over 20mm cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble and rounding of edges all around from inside and outside complete all as specified and directed.
13M&L granite 18-20 mm thick (of approved colour and texture) (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade or granite complete all as specified and directed.
14M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and as directed.
15M&L cement concrete (1:3:6) type C-1 using (using 20mm graded stone aggregate) 75mm thick as in plinth protection/Path etc finished fair and even laid in bays n.exc 2m in length and cutting of dummy joints 65mm deep x 10mm wide @ 3m intervals and at corners filled with bitumen mastic 1:3 complete all as specified and directed
16M&L for 10 mm thick rendering in cement plaster 1:6 on other than fair face of stone masonary or surfaces finished even and smooth without using extra cement including taking down old plaster and raking out joints complete all as specified and directed.
17M&L for rendering 15 mm thick cement plaster in two layers (10mm in cement mortat 1:6 as backing coat+5mm in cement mortar 1:4 finish coat with WPC) on fair faces of bricks or concrete surface finished even and smooth without using extra cement including taking down old plaster and raking out joints all as specified and directed. Note:- WPC shall be measured and paid seperately.
18Supply only Integral water proofing compound complete all as specified and directed.
19M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper including a coat of white cement based putty of 1-2 mm thick complete all as specified and directed by the Engr-in Charge.
20M&L complete removal of old decorated surface of wall and applying two coat of oil emulsion distemper white/coloured over and including one coat of white cement based putty all as specified and directed.
21M&L for preparation of newly plastered or unplastered surfaces in walls soffits, facia, chajjas and applying two coat of exterior weather proof water based emulsion over a coat of compatible primer complete all as specified and directed.
22M&L for finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm after complete removal of old decorated surface of wall complete all as specified and directed.
23Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each complete all as specified and as directed by the Engineer-in-Charge
24Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sq. m but not exc 4 sq. m each complete all as specified and as directed by the Engineer-in-Charge.
25S&F Factory made single extruded WPC (WoodPolymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65x125 mm comprisingof virgin PVC polymer of K value 58-60(Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic dditives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance tospread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia andlength complete as per direction of Engineer-in-Charge.
26S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of ngineer-In-Charge.
27S&F to Factory made single extruded WPC (Wood Polymer Composite) solid plain Glazed shutter door of 30 mm size open rebated and prepared to receive gauze, etc (without sash bars) edge of framing plain, chamfered or rounded, etc; size of members of shutters comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note : Wiremesh Shall be measured and paid separetely).
28S&F of 12mm thick toughened glass as in hinged doors, partitions or as fixed glass and similar work including cutting to shape, drilling holes required and fixing with necessary clips complete all as specified and directed.
29S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass , other parts made of mild steel heavy duty and fixed complete all as specified and as directed.
30S&F stainless steel heavy duty D-shaped patch lock and strike plated two set of keys suitable to be operated from both sides fixed to 12 mm thick glass door complete all as specified and as directed.
31S&F heavy duty stainless steel (grade 304) H shaped handles 300 mm long fixed to toughened glass door with one pair of collar and screws complete all as specified and as directed.
32S&F heavy weight stainless steel hydraulic patch fittings for single leaf having single bolt and single strock of minimum size 190 mm x 70 x 40 mm complete all as specified and as directed.
33S&F for 150 mm aluminium handles, cast type, anodised complete all as specified.
34S&F for ISI Marked 150mm long aluminium, anodized, barrel tower bolts of extruded section complete all as specified.
35S&F 300mm long, aluminium alloy anodised sliding door bolts with hasp and staple (bolt type) & fixing clip of sheet cast or extruded section & fixing bolt & sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
36S&F for 100mm stainless steel butt hinges (heavy) complete all as specified and directed.
37S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by the Engineer-in-Charge.
38S&F wire netting of galvanised steel wire 1.40mm dia and 12mm size of mesh fixed with tinned tacks of wire staples with complete all as specified and directed.
39S&F in reapir 18mm plywood grade BWR, type BB fixed with screws to timber frame work complete all as specified and directed by Engr-in-charge
40S&F in reapir 0.9mm thick decorative laminate type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per maker's instructions complete all as specified and directed by Engr-in-charge
41S&F in repair to cabinet Hinges Soft Close SS 8 Crank complete all as specified and directed
42S&F 100 mm stainless steel handle , cast type, polished bright complete all as specified and directed by Engr-in-Charge
43M&L for prepration of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
44M & L for preparation of old painted steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified & directed.
45Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
46Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 Grade St-240 all as specified and directed.
47S&F of framed work such as grills, gratings, cooler stands etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 including necessary fixing to openings as directed.
48S&F in repair powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) frame and shutters with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, suitable aluminum handle, handle lock/ mortice lock for door shutter etc all complete as per architectural drawings complete all as specified and directed.
49S&F Sheet glass 4 mm thick n exc 0.5 sqm in each pane fixed in aluminium or wooden windows complete all as specified and directed by Engr in charge.
50S&F 4.0 mm thick figured glass, pin headed type and glazed oil putty in square not 0.50 sqm in each pane complete all as specified and directed by Engr in charge.
51S&F 25mm stainless steel curtain rod premium quality incl taking down old rod with fittings complete all as specified and directed.
52S&F decorative type SS curtain rod bracket with cap of suitable for 25mm dia rod complete all as specified and directed.
53S&F of GI tubing Dia 15 mm dia 'medium weight' and all fittings on walls / ceilings or Laying in floors incl taking down old water tubing fixed in any positions complete all as specified.
54Cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
55S&F of GI tubing dia 20 mm dia 'medium weight' and all fittings on walls / ceilings or laying in floors incl taking down old water tubing fixed in any positions complete all as specified.
56S&F in repair 15mm bore dia chromium plated stop valve/angle cock, but fancy type, chromium plated with long shank and cup (concealed type) and fixed complete all as specified and directed
57S & F in repair 15mm bore, fancy type long body bib tap of cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by the Engineer-in-Charge.
58Taking down of PVC rainwater pipes and waste water pipe or gas pipe (any size or pattern) in any position , including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store complete all as specified and as directed.
59S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to wall with PVC clamps complete all as specified.
60S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified.
61S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with clamps complete all as specified.
62S & F 110mm bore PVC (SWR) bends of any radius with access door, jointed with solvent cement complete all as specified.
63S & F 75mm bore PVC (SWR) bends of any radius with access door, jointed with solvent cement complete all as specified.
64S & F for 75 mm bore PVC (SWR) junction (single T) with access door equal or unequal, jointed with solvent cement complete all as specified.
65S & F for 110mm bore PVC (SWR) junction( Single T) with access door equal or unequal, jointed with solvent cement complete all as specified.
66S&F of CPVC pipes SDR 11 &plain CPVC SDR 11 fitting on walls/celing or laying in floor jointed with solvent cement complete all as specified.
67M&L for 75mm bore PVC (SWR) floor trap/ multi trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
68Demolition of brickwork or stone /boulder masonry,built in CM including all quions,arches,pillars,etc but excluding ashlar facings.dressed stonework and precast concrete articles complete all as specified and as directed.
69M&L for brickwork with fly ash bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge
70M&L 15 mm thick, rendering in cm 1:4 on fair aces of bricks walls surface finished even and smooth without using extra cement including water proofing compound, all as specified and directed. Note- water proofing compound measured and paid seperately)
71M&L for endura joint free colour tiles 8 to 10 mm thick (square/rectangular) area of each tiles not exceeding 0.36 sqm , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles complete all as specified and directed..Make Johnson endura.
72M&L for 15mm thick, screed bed in cement mortar 1:6 complete all as specified and directed.
73S&F Providing and laying 60mm thick rubber moulded factory made chamfered edge cement concrete glossy finish paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer and filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed
74M&L for cement concrete type D2 (1:4:8) (using 40mm graded aggregate in foundations and mass-concrete etc including dismantling of old PCC complete all as specified and directed.
75Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface and getting out in any type of soils complete all as specified and directed.
76M&L PCC 1:3:6 Type C2 using 40 mm graded stone aggregate in foundation, filling and mass concrete as in boundary pillars and post etc all as specified and directed.
77Excavation in trenches n exc 1.5 m wide and n exc 1.5 m in depth beyond ; for foundation, etc. or for shafts, wells , cesspits, manholes, pier holes etc n exc 10 sqm on plan and not 1.5 m depth and getting out hard/dense soil complete all as specified and directed.
78Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soft / loose soil complete all as specified and directed.
79Removing excavated mtrl from site n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
80Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 150 mm internal dia of pipe complete all as specified and directed.
81M&L for laying DWCP 150mm dia, pipes in trenches class SN-8 conforming to IS 16098 (Part-2) in 6 mtr length with coupler complete all as specified and directed
82M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe with cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specified and directed.
83M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed.
84M&L cement 1:3:6, type C2, using 40mm aggregate in surface channel and drains etc. complete all as specified and directed.
85Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, incl forms, moulds, mitred/stoped ends etc complete all as specified and directed.
86Taking down carefully copper/aluminium point wiring concealed/ casing caping (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, call bell and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed.
87Dismantling/taking down of unserviceable old existing service /submain wire of any size all as specified and directed.
88Dismantling/taking down of unserviceable distribution boards with MCBs complete all as specified and directed.
89Taking down and refixing of storage type hot water Geyser of 50/35/25 litre capacity from different locations by disconnecting inlet/outlet connections complete all as specified & directed.
90Taking down carefully serviceable/unserviceable exhaust fans of any size from its position, and deposited to E/M office store yard all as specified and directed.
91Taking down carefully ceiling fans of any size from its position, and deposited to E/M office store yard all as specified and directed.
92Taking down and refixing of LED tube light fitting bright 18/20 Watt, slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
93Taking down carefully serviceable/unserviceable 2x2 LED 36 W light from its position, and deposited to E/M office store yard all as specified and directed.
94M&L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and includidng single core PVC insulated unsheathed flexible conductor FR-LS H cables 1.5 sqmm as per IS 694:2010 ISI marked annealed multistranded copper conductor drawn through and including medium machenical strees PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular / non modular type all accessories/fitting / metal flush box / cover plate/junctiion boxes/ inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FR-LSH cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including necessary plaster and poiinting in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and as directed Note:-cost of cutting chase and making good shall be included in the quated rates
95All as per Srl item No 93.00 here-in-before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed by Engineer - in - Charge.
96All as per Srl item No 93.00 here-in-before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge.
97All as per Srl item No 93.00 here-in-before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire.complete all as specified and directed by Engineer - in - Charge.
98All as per Srl item No 93.00 here-in-before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire.complete all as specified and directed by Engineer - in - Charge.
99S & F modular switch one way 6 Amp one module, 240 volts complete all as specified and directed by Engineer - in - Charge
100Supply and fixing modular socket outlet 2-in-1, 2/3 pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed by Engineer - in - Charge
101S & F modular switch one way 16 Amp one module, 240 volts complete all as specified and directed by Engineer - in - Charge
102Supply and fixing modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, controlled by one switch complete all as specified and directed by Engineer - in - Charge
103S&F modular ceiling rose 3 terminals 65x25 mm dia poly carbonate isolated complete all as specified and directed
104S&F modular lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified and directed.
105S & F in replacement stepped type modular electronic fan regulator as reqduired complete all as specified and directed by Engineer - in - Charge
106Supply & fixing in replacement LED tube light complete fitting 40 watt 220V, AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose comlete all as specified and directed by Engineer in charge .
107S & F in replacement LED lamp 10 Watt B22 CDL complete all as specified and directed by Engineer in Charge
108S&F LED ultra slim decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2, luminaire 36 watt Warm white in colour with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core complete all as specified & directed.
109Supply and fixing in replacement factory made epoxy powder coated distribution board TPN 4 ways ( VTPN MCCB DB ) and space for MCCB as incomer, with metal door ( IP-43 protection ) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated Neutral Bar, Insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed.NOTE:- MCCB shall be measured and paid seperatly.
110S&F in replacement MCCB 125 Amp, 3 Pole, breaking capacity 36 KA with complete electrical connections by appropriate size of copper lugs, complete all as specified and directed.
111S & F in replacement sheet metal enclosure double door type surface mounted concealed in wall 12 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
112S&F sheet metal enclosure for MCB, DB, TPN, 415 Volts, 200 amps rated busbar, 4 way, Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 54 including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and as directed. NOTE:- MCB shall be measured and paid seperatly.
113S & F in replacement sheet metal enclosure double door type surface mounted concealed in wall 4 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
114S & F in replacement MCB SP suitable for 240 volts, AC supply 6 to 32 Amps , with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
115S & F in replacement MCB SPN suitable for 240 volts, AC supply 40 to 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
116S&F in repair MCB TP suitable for 415 volts, 'B' curve,AC supply 100 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA, complete all as specified and directed.
117S&F in repair MCB, TPN suitable for 415 volts, 'B' curve,AC supply 100 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA, complete all as specified and directed.
118M&L in replacement for sub main wiring (Single phase) with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
119M&L in replacement for sub main wiring (Three phase) with four runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 10 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 25mm dia with its accessories, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 10 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Four runs of 10 sqmm cable & one run of 10 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
120M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with three single core PVC insulated ISI marked FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire complete all as specified and directed. Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
121M&L in replacement for sub main wiring (Three phase) with four runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 25mm dia with its accessories, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Four runs of 4 sqmm cable & one run of 4 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
122S&F in replacement building security light fitting complete with 36 watt LED, type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out of GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed
123M&L in replacement of earthing complete with galvanised steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m deep below normal ground level and connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 metre long all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
124Supply and fix in replacement sheet metal enclosures with socket plug top and MCB's with two pin and earth plug and socket complete with one Single pole MCB 240 V grade 25/20 Amp complete all as specified and directed .
125Supply and fix in replacement heavy duty exhaust fan, steel body AC single Phase, 230V of size 380mm sweep with, including cutting of hole in existing wall and resurfacing of disturbed area of wall with blades, and frame and louvers complete all as specified and directed.
126Supply and fix heavy duty exhaust fan, steel body AC single phase, 230V of size 300 mm sweep with, blades, and frame and louvers including cutting of hole in existing wall and resurfacing of disturbed area of wall complete all as specified and as directed.
127Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) without remote controller complete all as specified and as directed.
128Supply, installation and commissioning heavy duty electrical single phase, 230 Volt chimney wall mounted suction capacity not less than 1600 cubic meters per hour & sensor based control , made of SS 304 Grade with a baffle system , auto control features, size not less than 24 inch incl GI duct of thickness 1 mm with support frame with nut , bolts , fasteners complete all as specified and directed by Engr -in- charge.
129Supply and fix wall mounted fan of metal body with plastic blades, 400 mm sweep, 1350 RPM, 55 watts, 240 V, 50 Hz, air deliver 65 m³ per minute, three Nos of speed controlling complete all as specified and all as directed.
130M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed.
131M&L for providing of un-reinforced precast concrete cable cover class LV, Type 1 size 250mmx 150mm x 40mm laid flat dry for protection of under ground cable complete all as specified and directed.class,, flat,
132Supply, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 35 sqmm 3.5 core all as specified & directed. Note:- Excavation & earth work and pipe / sand / bricks for cable protection shall be measured and paid for separately under appropriate item of this schedule)
133M & L GI Tubing \\"light grade\\" galvanized for protection LT Cable all as specified of size 40 mm bore complete all as specified and directed by Engr-in-Charge.
134Taking down carefully 25 mm GI tubing of any type including connected fittings from its position, and deposited to E/M office store yard all as specified and directed.
135Supply and fix GI tubing medium grade of size 25mm dia ISI Mark galvanised laid in floors/walls including fittings such as bends elbows,sockets reducers etc complete accessories .
136Supply and fixing Gun metal gate valve/glove valve ISI marked with Iron wheel head screwed both end for GI tubing of size 20 mm dia complete all as specified and directed
137Supply and fixing 25mm Gun metal gate valve/glove valve ISI marked with Iron wheel head screwed both end for GI tubing of size 25 mm dia complete all as specified and directed
138S&F 1000 ltrs capacity rotational moulded 3 layer HDPE water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in IS Code -12701-1996 complete all as specified and directed
139Deduct Schedule of credit (calculation will be done off line) Rs. 15437.00 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56096383
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25.47 Lakhs
LAST DATE 18-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Or Cook House And Dining Hall Of Bldg No. T-193 A At Si Lines Under Ge Bhopal
Basic Detail
Tender No 8600/E8
Bidding Type Tender
Location
City Bhopal
State Madhya Pradesh
Key Dates
Publish Date 11 Jul 2026
Submission Date 18 Jul 2026
Open Date 20 Jul 2026
Finance
Tender Value 25.47 Lakhs
Tender Fee 500
EMD 51000
Exemption Available
Document List
BOQ_866394.xls
credit8600.pdf
d93ad595-d831-41c2-a862-2382177000a4.html
Tendernotice_1 (2).pdf
TENDER_DOCU_8600.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 18, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Jul 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Jul 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_866394.xls

pdf

credit8600.pdf

html

d93ad595-d831-41c2-a862-2382177000a4.html

pdf

Tendernotice_1 (2).pdf

pdf

TENDER_DOCU_8600.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders