Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Surface excavation not exceeding 30 cm deep and averging 15 cm deep and getting out in soft loose soil complete all as specified and as directed |
| 2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation,laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in all type soil/rock , complete all as specified and directed. |
| 3 | Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in deep but not exceeding 3.0 mtr for foundations, laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 10 Sqm on plan and getting out in all type soil/rock , complete all as specified and directed. |
| 4 | M&L for Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soils complete all as specified and directed. |
| 5 | M&L for Removal of excavated material soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 6 | M&L plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed . |
| 7 | M&L precast cement concrete (1:3:6) type C-1(using 20mm graded crushed stone aggregate) as in solid building block or slabs 10cm thick and setting in cement mortar 1:4 complete in wall all as specified & directed by Engineer-in-charge. |
| 8 | M & L for rendering 15 mm thick in cement mortar 1:4 on concrete/brick /stone surfaces with liquid water proofing compound,mixed @ 200 ml/50 kg per bag of cement ,complete all as specified and directed .(Note:Water proofing compound shall be measured and paid seprerately under respective item of \\"BoQ\\") |
| 9 | M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in kerb/benching/copings, bed plates, plinth courses, parapets including weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form work etc complete all as specified and directed |
| 10 | Demolition and breaking up 300 mm bore RCC/Salt glazed stoneware drain pipe set & jointed in cement mortar laid in trenches complete all as specified and as directed . |
| 11 | Demolition and breaking up 200 mm bore RCC/Salt glazed stoneware drain pipe set & jointed in cement mortar laid in trenches complete all as specified and as directed . |
| 12 | Demolition and breaking up 150 mm bore RCC/Salt glazed stoneware drain pipe set & jointed in cement mortar laid in trenches complete all as specified and as directed . |
| 13 | Supply , laying jointing and testing 300 mm bore reinforced cement concrete drain pipes of class NP-2 (ISI Marked) with one collar per length of pipe, laid and jointed in trenches and jointed in cement mortar 1:1 complete all as specified and as directed. |
| 14 | Supply , laying jointing and testing 200 mm bore reinforced cement concrete drain pipes of class NP-2 (ISI Marked) with one collar per length of pipe, laid and jointed in trenches and jointed in cement mortar 1:1 complete all as specified and as directed. |
| 15 | Supply , laying jointing and testing 150 mm bore reinforced cement concrete drain pipes of class NP-2 (ISI Marked) with one collar per length of pipe, laid and jointed in trenches and jointed in cement mortar 1:1 complete all as specified and as directed. |
| 16 | Supply , laying jointing and testing 450 mm bore reinforced cement concrete drain pipes of class NP-2 (ISI Marked) with one collar per length of pipe, laid and jointed in trenches and jointed in cement mortar 1:1 complete all as specified and as directed. |
| 17 | M & L for cement concrete bed to 450 mm bore drain pipe ( NP2) including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) including necessary shuttering and tested of pipes complete all as specified & as directed |
| 18 | M & L for cement concrete bed to 300 mm bore drain pipe ( NP2) including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) including necessary shuttering and tested of pipes complete all as specified & as directed |
| 19 | M & L for cement concrete bed to 200 mm bore drain pipe ( NP2) including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) including necessary shuttering and tested of pipes complete all as specified & as directed |
| 20 | M & L for cement concrete bed to 150 mm bore drain pipe ( NP2) including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) including necessary shuttering and tested of pipes complete all as specified & as directed |
| 21 | M&L for Construction of Septic Tank for 300 users including necessary earth work in excavation in any type of soil, plain cement concrete 1:2:4 type B-2 ( using 40 mm graded crushed stone aggregate ) as in foundation laid over stone hard core , R R masonary in cement mortar 1:4, ,reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast man hole cover slab having 8 mm dia TMT bar reinforcement @ 75 mm c/c & 6 mm thick mild steel plate embedded all around of cover slab,15 mm thick plaster in cement sand mortar in 1:4 on wall, vent shaft, sludge chamber , form work to sides and soffits, 150 mm dia SGSW inlet & out let pipes up to 3 m from outer face of wall, CI vent pipe, sludge chamber, RCC baffle wall, returning filling & removal etc, complete all as shown on drawing No.CEJZ/TD/31 dt 14 Dec 2013 Sheet No.1/3 to 3/3 as specified. |
| 22 | M&L for Construction of Soakage well for 3.00mtr dia( internal dia ) & 6.0 m (effective depth) including necessary excavation in earth work in any type of soil , plain cement concrete 1:3:6 type C-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , RR masonary in cement mortar 1:4 in walls & honey masonary , reinforced cement concrete M-30 (design mix) as in slab cover including pre-cast cover slab having 8 mm dia TMT bar reinforced,plain cement concrete band and dwarf wall, form work to sides and soffits of RCC slab & filling with brick bats loose filling including interconnecting pipes of RCC /DWC complete all as specified and shown in drawing No. Tdrawaing no.CEJZ/TD/29 dt 14 Dec 2013 Sheet No. 1/3 complete all as specified. |
| 23 | M&L for precast reinforced cement concrete 1:2:4 ,type B-1 (using 20 mm graded crushed stone aggregate) as in kitchen platform, shelves ,drain/man hole cover slab, etc. including necessary formwork & set in cement mortar 1:4 complete all as specified and directed. Note : (i) Reinforcement will be measured & paid seperately under respective item of BOQ. (ii) Slab covers shall be floated with surface vibrator,and over turfed base ,arrangement for turfed base has to be from contractors side. |
| 24 | M&L for squared rubble walling, Jodhpur type, regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6, complete all as specified and directed. |
| 25 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete ,using extra cement ,including forms moulds ,mitered/stopped ends etc complete all as specified and as directed |
| 26 | Supply only integral water proofing compound ISI marked complete all as specified and as directed |
| 27 | M & L for PCC 1:3:6 type C-1(using 20 mm graded crushed stone aggregate) as in surface channels/benching of manhole, drain, laid to shape and slope and surfaces finished even and smooth using extra cement, complete etc all as specified and directed. |
| 28 | Cutting in to existing manhole for connecting new drains,making good to pipe and rendering ,cutting out existing benching and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150mm/200mm/300mm complete all as specified and as directed |
| 29 | Pumping out /Cleaning/taking out sludge/mud/silt from the existing manholes of any size / any capacity and any type of manholes of material like solid/fluid, mud sludge etc by mechanical motorised suction machine and deposited /removing the sludge etc outside the MOD land area to a distance exceeding 10 KM shall be conveyed in closed container vehicle of having capacity of 3000 ltr in each trip and also disposed off in the place properly using bleaching powder etc and buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified and as directed.(a) Depth of manhole not exceeding 0.50mtr |
| 30 | Pumping out /Cleaning/taking out sludge/mud/silt from the existing manholes of any size / any capacity and any type of manholes of material like solid/fluid, mud sludge etc by mechanical motorised suction machine and deposited /removing the sludge etc outside the MOD land area to a distance exceeding 10 KM shall be conveyed in closed container vehicle of having capacity of 3000 ltr in each trip and also disposed off in the place properly using bleaching powder etc and buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified and as directed.(b)Depth of manhole not exceeding 1.0 mtr |
| 31 | Pumping out /Cleaning/taking out sludge/mud/silt from the existing manholes of any size / any capacity and any type of manholes of material like solid/fluid, mud sludge etc by mechanical motorised suction machine and deposited /removing the sludge etc outside the MOD land area to a distance exceeding 10 KM shall be conveyed in closed container vehicle of having capacity of 3000 ltr in each trip and also disposed off in the place properly using bleaching powder etc and buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified and as directed.(b)Depth of manhole exceeding 1.0 mtr but not exceeding 2.0 mtr |
| 32 | Cleaning of blockage sewage line manually (cleaning length not exceeding 30 m from man hole or from manhole to septic tank) 150mm dia/bore of SGSW/RCC pipe and passing drubber ball of suitable size through line to ensure all blockage perfectly clear to the entire satisfaction of Engineer-in-charge and well flushing by using sufficient water and making it clear for easy flow of sewage up to the septic tank including cleaning of manhole sludge, silt etc removing the sludge in low lying area and burying it in pits and replacing manhole cover in position after cleaning complete as directed by Engineer-in-Charge. |
| 33 | Cleaning of blockage sewage line manually (cleaning length not exceeding 30 m from 200 mm dia/bore SGSW/RCC of pipe and passing drubber ball of suitable size through line to ensure all blockage perfectly clear to the entire satisfaction of Engineer-in-charge and well flushing by using sufficient water and making it clear for easy flow of sewage up to the septic tank including cleaning of manhole sludge, silt etc removing the sludge in low lying area and burying it in pits and replacing manhole cover in position after cleaning complete as directed by Engineer-in-Charge. |
| 34 | Cleaning of blockage sewage line manually (cleaning length not exceeding 30 m from man hole or from manhole to septic tank) 300mm dia/bore of SGSW/RCC pipe and passing drubber ball of suitable size through line to ensure all blockage perfectly clear to the entire satisfaction of Engineer-in-charge and well flushing by using sufficient water and making it clear for easy flow of sewage up to the septic tank including cleaning of manhole sludge, silt etc removing the sludge in low lying area and burying it in pits and replacing manhole cover in position after cleaning complete as directed by Engineer-in-Charge. |
| 35 | Cleaning of blockage sewage line manually (cleaning length not exceeding 30 m from 450 mm dia/bore SGSW/RCC of pipe and passing drubber ball of suitable size through line to ensure all blockage perfectly clear to the entire satisfaction of Engineer-in-charge and well flushing by using sufficient water and making it clear for easy flow of sewage up to the septic tank including cleaning of manhole sludge, silt etc removing the sludge in low lying area and burying it in pits and replacing manhole cover in position after cleaning complete as directed by Engineer-in-Charge. |
| 36 | S&F 50 to 75 mm thick Jodhpur type machine cut stone slab not exceeding 2m in length dressed all face & along exposed edged size faced both sided as in drain cover/MH covercomplete all as specified and as directed . |
| 37 | M&L for hard core of broken stone or boulder gauge not exceeding 63mm deposited, spread & leveled in layers not exceeding 15cm thick, watered and rammed to a true surface etc complete all as specified& directed. |
| 38 | M&L precast cement concrete block masonry using PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) solid blocks, exceeding 10 cm in width and setting in cement mortar 1:4, straight or curved on plan exceeding 6 m mean radius complete all as specified and directed. |
| 39 | M&L reinforced cement concrete M-20,type A-1 (nominal mix) (using 20 mm graded crushed stone aggregate) as in as in walls, retaining walls, basement walls, ballast walls and the like, any footing ,including attached pilasters and buttressed etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ. |
| 40 | M&L reinforced cement concrete M-20,type A-1 (nominal mix) (using 20 mm graded crushed stone aggregate) as in coloumns, pillars, piers,post and struts etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ. |
| 41 | M&L reinforced cement concrete M -20,type A-1 (nominal mix) (using 20 mm graded crushed stone aggregate) as in beams; cantilever ,bressummers,lintel over1.50mtr span etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ. |
| 42 | M&L reinforced cement concrete M -20,type A-1 (nominal mix) (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ. |
| 43 | Use & waste of form work to sides of concrete foundation, base of column ,rafts,footings, plinth beams, and plinth beam and similar work for rough finished flat surfaces of concrete complete all as specified and directed. |
| 44 | Use and waste of form work to sides of columns, pillars, piers, post and struts for rough finished surface of concrete complete all as specified and directed. |
| 45 | Use and waste formwork to sides & soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc.for rough finished surface of concrete complete all as specified and directed. |
| 46 | Use and waste of form work to sides of soffit of suspended slab such as roof slab ,floor slab ,landing and similar work , not exceeding 200 mm thick for rough finished surface of concrete complete all as specified and directed. |
| 47 | Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide rough finished surface of concrete complete all as specified and directed. |
| 48 | M&L for mild steel TMT bars 10mm dia and over grade Fe-500, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. |
| 49 | M&L for mild steel TMT bars 08 mm dia and over grade Fe -500 , as in stirrups, spacers & binders ,cut to length, bent to shape required, including cranking bending spirally for hooping for coloumn,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. |
| 50 | M&L for 15mm thick rendering on stone masonry surfaces or on fair face of brick work or concrete surface in cement mortar 1:6,finished even and smooth without using extra cement complete all as specified and directed. |
| 51 | M&L for 5mm thick cement plastering in cement mortar 1:3 on concrete ceiling /chajjas surfaces, finished even & smooth without using extra cement omplete all as specifed and as directed. |
| 52 | M&L for 75 mm thick plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring & mass concrete etc complete all as specified and directed. |
| 53 | M & L for non skid coloured ceramic tiles 7 to 8 mm thick (sqaure/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc.,over and including 15mm thick screed bed in cement mortar (1:6) set and jointed in neat cement slurry and pointed in coloured cement to match the existing surfaces, complete all as specified and directed. |
| 54 | M & L glazed ceramic coloured tiles of size 350 mm x 250 mm x7mm thick / 450 mm x 350 mm x7mm thick ,as in vertical surface such as dado/skirting etc ,set and jointed in neat cement slurry and pointed in colour cement to match the tiles, over & including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 55 | S & F solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tubes suppyling & fixing in opening as per specification & drawing complete all as spcefied and directed by Engineer-in-Charge. |
| 56 | S & F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tube for top and bottom rails. mild steel framed shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS framed welded/sealed to stiles & rails with suitable PVC sheet beading & joined together with solvent cement complete all as fixing in the frame at site as per specification and drawing complete all as specified and as directed. |
| 57 | S & F 100mm size butt hinges stailess steel complete all as specified and directed . |
| 58 | S&F 150 mm extruded aluminium alloy handles of extruted section type, anodised complete all as specified & directed. |
| 59 | S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 60 | S&F 250 mm long aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 61 | Supply and fixing Aluminium anodised ventilator frame and shutter including all required fittings etc.complete all as specified and directed. |
| 62 | S&F stainless steel I- Max hinges for suitable to alu vents all as specified and directed |
| 63 | S&F aluminium alloy wire cloth o.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire stappler. |
| 64 | S&F 3.0 mm thick figured glass pin headed type in squares/ rectangular not exceeding 0.5 Sqm in each pane glazing with oil putty or aluminium frame/shutters with rubber neoprene beading complete etc all as specified & directed. |
| 65 | S&F WC squatting pan \\" Orissa Pattern\\" of size 580 mm X 440 mm white with integral foot rest including cast iron \\"P\\" or \\"S\\" trap, front or back inlet and making connection to trap & to flushing cistern including flush pipe 40mm dia HDPE pipe etc, and provision of cement concrete bedding and making good to floor complete etc all as specified & directed. |
| 66 | S & F vitreous China wash basin, any colour, flat back size 630 mm X 450mm including 32mm brass chromium plated waste coupling ,chromium plated grating including bracket back with pedestal including bracket ,chain and plug, 2 Nos PVC connection 15 mm size & 45-60cm long complete etc all as specified & directed. |
| 67 | S&F vitreous China urinals half stall with including urinal spreader of PTMT with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)(back or corner wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and Union for discharge pipe etc.complete all as specified and as directed |
| 68 | S & F PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float & handle, and brackets complete set & making good disturbed surface with CM 1:3 complete all as specified and directed. |
| 69 | S&F bevelled edge mirror of selected quality glass of size 600mm x 450mm fancy type frame, mounted on 6mm thick AC building board or commercial plywood & fixed to wooden plugs with CP brass screws & cup washers complete all as specified and directed. |
| 70 | S & F for 110 mm bore PVC(SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall including stack clamp 50mm x 3 mm mild steel flat iron properly with nut ,bolts & PCC 1:2:4 complete all as specified and directed |
| 71 | M&L for 75mm dia PVC (SWR) floor trap with grating chromium plated with or without hole including joining to waste pipe,fixed in cement concrete 1:2:4, type B-1,complete all as specified and directed. |
| 72 | M&L for PVC (SWR) multifloor trap 75 mm dia with grating including jointing with solvent cement with chromium plated grating with or without hole complete all as specified and directed. |
| 73 | S & F for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches, complete all as specified and as directed by Engineer-in-charge. |
| 74 | S & F for 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches, complete all as specified and as directed by Engineer-in-charge. |
| 75 | S & F for PVC (SWR) bends for 110 mm bore pipe, with rubber ring joints, complete all as specified and as directed. |
| 76 | S & F for PVC (SWR) 110 mm bore junction single, (Single T) equal or unequal, with rubber ring joints, complete all as specified and as directed. |
| 77 | S & F for PVC (SWR) bends with access door for 75 mm pipe, with rubber ring joints, complete all as specified and as directed. |
| 78 | S& F for PVC connection 15 mm dia size with PTMT nuts of length 450 mm complete all as specified and directed. |
| 79 | S & F 32 mm bore unplasticised PVC waste pipes of pressure rating 6 kgf/Sq.cm fixed complete to walls, or in floors etc, suitable for wash hand basins/Urinal complete all as specified & directed. |
| 80 | S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with aluminium alloy brackets and gaurd and railing 60cm long complete all as specified |
| 81 | S&F towel rail brass chromium plated towel rail , 20 mm dia ,D-type 600 mm long between flanges fixed with and including chromium plated brass screw & wooden /plastic cleats complete set all as specified and directed. |
| 82 | S&F 15mm bore long body (weight not less than 400 gm) bib tap, cast copper alloy, CP fancy type with crutch or butterfly handle, screw down, screwed for iron pipe or for brass ferrule including flange complete all as specified and directed |
| 83 | S&F 15mm dia bore angle stop valve cast copper alloy fancy type, chromium plated with long shank and cup (concealed type) screwed down high pressure with crutch or butterfly handle screwed bot ends for iron pipe or for unions complete all as specified and directed |
| 84 | S & F 40 mm bore unplasticised PVC waste pipes of pressure rating 10 kgf/Sq.cm fixed complete to walls, or in floors etc, suitable for wash hand basins/Urinal complete all as specified & directed. |
| 85 | M & L for application of water proofing treatment using APP modified roof membrane over non accessible/ non approachable RCC roof slab / chajjah / canopy / parapet wall( horizontal/vertical surface) to be executed through approved applicator of the membrane manufacturer/authorized applicator of the manufacturer with following specification etc complete all as specified and directed :-(a) Cleaning existing surface properly with wire brush .(ii) Applying neat cement slurry @ 3.00 kg/Sqm and screeding / bedding layer of 10 mm thick in CM 1:4 mixed with water proofing compound as per manufacturer instructions laying of water proofing treatment including providing the following stage as roof treatment complete all as specified and as directed by Engr-in-Charge : - (a) FIRST COURSE: Applying a coat of bituminous primer @ 0.4 litre / Sqm manufactured by the same agency that of APP with a density 0.87 to 0.89 Kg/litre at 25 degree celsius on prepared plastered surfaces. (b) SECOND COURSE: Applying one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm (c) THIRD COURSE : Provide a layer of APP modified polymeric membrane centre core of 100mm micron HMHDPE, outer film 20 micron each, thickness 3.00mm having weight not less than 2.25 Kg/Sqm using butane torch application method with minimum 10cm side lap and 15cm end lap complete .(d) FOURTH COURSE : Applying one coat of bonding material using blown type bitumen confirming to IS- 702 grade 85/25 @ 1.20 Kg/Sqm.NOTE :- 1. A Information Tablet will be put up in the front side wall of the buildings where this work will be done. All building/structure shall be provided with plaque (tablet) furnishing the information as per PS clause No. 21.3, in plaster engraving in and painted as directed by GE 2.WPC shall be measured and paid separately under respective item. |
| 86 | M&L for preparation of newely plastered surfaces of wall and applying three coats of white wash on wall surface complete all as specified & directed. |
| 87 | M&L for preparation of newely plastered surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified & directed. |
| 88 | M&L for preparation of new plastered surfaces of walls/chajja/lintel and applying two coats of cement based paint white or tinted over a coat of alkali resistant primer complete as specified and directed. |
| 89 | M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-1 (using 20mm graded crushed stone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85/25 grade and sand in the ratio 1:3 including necessary form work , complete all as specified and directed. |
| 90 | S&F rotational moulded polythene water storage tank of capacity 1000 ltrs (Cylindrical/vertical with closed type), triple layer construction, ISI marked, hoisted and fixed in position including 20 mm bore GI nipple and 25 mm bore ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms) complete all as specified and directed. |
| 91 | S&F for GI water tubing medium grade, ISI marked, galvanised, 20 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chases for brick walls and making good the surface in cement mortar 1:3 complete all as specified & directed. |
| 92 | Supplying and laying of CPVC pipes, 20 mm outer dia of pipe, SDR 11 & Plain CPVC SDR 11 including all brass fittings, laid in trenches or ceiling or fixed to wall complete all as specified. |
| 93 | Supplying and laying of CPVC pipes, 25 mm outer dia of pipe, SDR 11 & Plain CPVC SDR 11 including all brass fittings, laid in trenches or ceiling or fixed to wall complete all as specified. |
| 94 | M&L for modular point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR-LSH cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit 20mm dia with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FR-LSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, fan regulators complete for the following :-(a) One light/fan/bell point controlled by one, one way switch. |
| 95 | All as per item No. 94.00 above but one 5 pin 5 or 6 Amps socket outlet on same board. |
| 96 | S&F modular switch 1 way 6 Amp, 1 module complete all as specified and directed. |
| 97 | S&F modular socket 6 Amp, 2/3 pin combined 2 module complete all as specified and directed. |
| 98 | S&F ceiling rose surface bakelite 3 terminals 230 Volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge. |
| 99 | S&F bldg security LED Light Luminaire of 35/45 Watts having IP 65 protection fiting made out of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protectore, toughened glass with and including GI pipe 40 mm bracket of 1.5 m in length including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable, complete all as specified and as directed. |
| 100 | S&F warm white LED lights fitting 1 x 20W, 220V AC decorative box type with driver holder including AC decorative box type with driver holder including copper conductor cable of suitable size from ceiling rose complete 4 ft long all as specified and directed. |
| 101 | S&F LED Cool white light fitting mirror type with high out put difuser 2 feet 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 102 | S&F MCB, B Curve type, breaking capacity 10 kA, 63Amp, SPN with over load and short circuit protection, complete all as directed. |
| 103 | S&F MCB, B Curve type, breaking capacity 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as directed. |
| 104 | Supply and fixing as MCB DB SPN (double door) 12 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall incl dismantling of old UNSV DB complete all as specified and directed. |
| 105 | Supply and fixing exhaust fan made of sturdy engineering plastic complete with louvers shutter voltage 230V, 50 Hz, RPM 1200 copper winding of sweep 250mm complete all as specified and directed |
| 106 | M&L for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 mm dia with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead. |
| 107 | Supply, laying testing LT UG XLPE in trenches/saddle clamping on wall (as per site requirement insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,croos sectional area 16 sqmm 2 core all as diredted by Engr - in - charge. Note : Earth work and brick work measured and paid separately |
| 108 | Supply and laying unreinforced Precast concrete cable cover, class LV, type 1, flat size 300 mm x 180 mm x 40mm, complete all as specified and directed. |
| 109 | Supply and laying of sand for sand cushioning for cable protection in trenches including punning down of sand layer all as specified and directed. Note :- Punned thickness shall only be measured and paid. |
| 110 | S&F of GI tubing , light grade of 40mm bore with fittings as in road crossings for cable protection complete all as specified and as directed. |
| 111 | NOTE:- (i) Qty's have been clubbed from 2 Nos sanction Job's, whose details are encl as per appx.(ii) The contract sum shall be arrived at after deducting amount of schedule of \\"Credit\\" from the Total quoted amount. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail