| 1 | Periodical maintenance and inspection/checking of following size /capacity of DG sets and ensuring smooth functioning of DG sets and replacements of unsv parts of DG sets of following capacities : - Note:- Spare parts required shall be measured and paid separately . |
| 2 | 30 KVA DG SET |
| 3 | Supply and fixing in Replacement bypass filter element with O ring of Kirloskar /Crompton greeves/Mahindra DG Sets as required at site as per make and model for the following capacities of DG Sets :- |
| 4 | 30 KVA DG SET |
| 5 | Supply and fixing in Replacement luberication oil filter element with 'O' ring of Kirloskar /Crompton greeves/Mahindra DG Sets as required at site as per make and model for following capacities of DG Sets :- |
| 6 | 30 KVA DG SET |
| 7 | Supply and fixing in Replacement Air filter element inner and outer as required at site with 'O' ring of Kirloskar /Crompton greeves/Mahindra DG Sets as required at site as per make and model for following capacities of DG Sets :- |
| 8 | 30 KVA DG SET |
| 9 | Supply and fixing in Replacement fuel filter element with 'O' ring of Kirloskar /Crompton greeves/Mahindra DG Sets as required at site as per make and model for following capacities of DG Sets :- |
| 10 | 30 KVA DG SET |
| 11 | Supply and fixing in Replacement fan belt of Kirloskar /Crompton greeves/Mahindra DG Sets as required at site as per make and model for the following capacities of DG Sets :- |
| 12 | 30 KVA DG SET |
| 13 | Supply and fixing in Replacement distilled water to be filled in batteries ,complete all as specified and directed by Engineer-in-charge. |
| 14 | Supply and fixing in Replacement ignition switch with key in repair for DG sets of any capacities, complete all as specified and directed by Engineer-in-charge. |
| 15 | Material & Labour for replacement of battery cable of size 40 sqmm PVC insulated multi stranded copper conductor single core cable with necessary lugs, complete all as specified and directed by Engineer-in-charge. |
| 16 | Supply and filling in Replacement top up coolent for DG set radiator |
| 17 | Supply and fixing in Replacement Water temperature gauge for 30 KVA KVA DG set complete all as specified and as directed. |
| 18 | Supply and fixing in Replacement oil pressure gauge assembly for 30 KVA DG set complete all as specified and as directed. |
| 19 | Supply and fixing in Replacement oil temperature gauge for 30 KVA DG set complete all as specified and as directed. |
| 20 | Supply and fixing in Replacement cable for Techno meter for 30 KVA DG set complete all as specified and as directed. |
| 21 | Supply and fixing in Replacement Techno meter assembly for 30 KVA DG set complete all as specified and as directed. |
| 22 | Supply and fixing in Replacement flexible braided hydraulic hose 5/8\\" dia x 600 mm length including suitable check nuts & washers, complete all as specified and directed by Engineer-in-charge. |
| 23 | Supply and fixing in Replacement RPM metre with cable (0-3000 RPM),, complete all as specified and directed by Engineer-in-Charge. |
| 24 | Supply and filling in Replacement lube oil SAE 15 W - 40 for Top up and filling up the oil in the sump after completely flushing the old oil out of the tank and cleaning of the tank for fresh filling, complete all as specified and directed by Engineer-in-charge. |
| 25 | Supply and fixing in Replacement battery terminal heavy duty as per sample made of brass with bolts and washers all as required at site,, complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply and fixing in Replacement complete 12 V 180 AMPH maintenance free battery and initial charging complete including inbuilt charger including required electrolyte /distilled water etc and fixing as required at site to the concerned DG Set, complete all as specified and directed by Engineer-in-charge. |
| 27 | Supply and fixing in Replacement of self starter assembly for DG set for 30 KVA 12 volts DC including, complete fixing and testing, complete all as specified and directed by Engineer-in-charge. |
| 28 | Supply and fixing in Replacement Rubber hose set for DG set radiator by replacing the unserviceable hose set ,for 30 KVA DG set complete all as specified as directed by Engineer-in-charge. |
| 29 | Supply and fixing in Replacement PLC system for DG sets of 30 KVA capacities , complete all as specified as directed by Engineer-in-charge. |
| 30 | Supply and fixing in Replacement of turbo charger,320 complete all as specified as directed by Engineer-in-charge. |
| 31 | Material and labour for dismantling of radiator from engine taking it to work shop repair of leakage pipes, cleaning the radiator with cleaning agents, re-assembling to the engine completely to enting satisfaction of Engineer-in-Charge |
| 32 | Inspection/checking of AMF panel of DG set of capacity 30 KVA installed at various installations of any make and shape and rectify the defects, replacement of unserviceable part as required at site and cleaning of AMF panel as detecting during inspection or pointed out by users/department and carry out maintenance , complete all as specified as directed by Engineer-in-charge. Note:- Spare parts required shall be measured and paid separately . |
| 33 | Supply and fixing in Replacement 4 Pole power contactor with AC coil 80 Amps, 3 phase 415 volt 50 HZ suitable for AMF panels complete all as specified as directed by Engr-in-Charge |
| 34 | Supply and fixing in Replacement engine start relay 12 volt DC suitable for AMF panels Complete all as specified as directed by Engr-in-Charge |
| 35 | Supply and fixing in Replacement frequency meter 45 to 55 HZ AC 415 volt of size Sqmm suitable for AMF panels complete all as specified as directed by Engineer-in-Charge. |
| 36 | Supply and fixing in Replacement selector switch for volt/ampere metre 415 volt four stage suitable for AMF panels Complete all as specified as directed by Engr-in-Charge |
| 37 | Supply and fixing in Replacement cranking relay 12/24 volts DC 8/11 stage suitable for AMF panels complete all as specified as directed by Engineer-in-Charge. |
| 38 | Supply and fixing in Replacement indicator lamp assembly LED type with red/green/blue for phases R,Y,B suitable for AMF panels complete all as specified as directed by Engineer-in-Charge. |
| 39 | S & F Change over main switch, on load, four poles, 630 Amps, 415 Volts, 36 KA ,50 Hz, with enclosure, fixed in the existing LT panel board/ sheet metal enclosure including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed. |
| 40 | S&F galvanized lron water tubing medium grade with & including all fittings such as bends tees,short pieces connectors back nuts diminishing pieces caps ,plugs and union etc and fixing complete with clips wall hooks wooden plug etc complete all:- |
| 41 | All as per Srl item No 34 above but 15 mm dia bore. |
| 42 | All as per Srl item No 34 above but 25 mm dia bore. |
| 43 | All as per Srl item No 34 above but 40 mm dia bore. |
| 44 | S & F as in repairs hot water steel water tubing, 15 mm bore,medium grade, galvanised,with all fittings such as bends,tee,short piece, connectors,back nuts, diminishing pieces,caps ,plugs and union etc fixed complete to walls and ceilings or laid in floors including insulation with glass wool,wiremeshand aluminium cladding complete all as specified and directed. |
| 45 | All as per Srl item No 35 above but 20 mm dia bore. |
| 46 | All as per Srl item No 35 above but 25 mm dia bore. |
| 47 | Supply, laying, jointing and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 10 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc. including taking out old unserviceable cable complete all as specified. |
| 48 | S&F as in Rotational moulded polyethylene water storage tanks cap 500 ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified. |
| 49 | Supply and fixing as in repairs Ball valves, high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball, screwed for iron pipe 25 mm dia (minimum weight 455 gms) complete all as specified and as directed. |
| 50 | S&F in replacement gun metal globe or gate valve 15mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge. |
| 51 | S&F in replacement gun metal globe or gate valve 25mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge. |
| 52 | S&F in replacement Brass CP mixer 15mm bore for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-charge. |
| 53 | Supplying & laying in trencies Polyethylene (PE-AL-PE) 15mm dia bore compositc pressure pipes includin all Crimp type internal sealing Plastic-Metal Composite fittings (such as elbows, tees, reducers, etc.) complete all as specified and as directed. |
| 54 | All as per Srl item No 44 above but 25 mm dia bore. |
| 55 | S&F sheet metal enclosure comprising with socket plug ,Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amp complete all as specified and as directed. |
| 56 | S&F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amp all as specified and as directed. |
| 57 | S&F in replacement of stainless steel tank of 1000 LPD capacity solar water heater as per existing size and shape complete all as specified and as directed |
| 58 | S&F 20mm bore bib tap standard of chromium plated, high pressure, screwed for iron pipe and fixed complete all as specified and as directed. |
| 59 | M&L servicing and maintenance of complete solar water heater plant of capacity 500 LPD installed at single/double story buildings including carrying out repair to minor leakage, brazing work ,cleaning of flat plate collector glass & cleaning of HDPE water tank and make up tank including dismantling inlet and outlet connections and refixing the same after cleaning for proper functioning to maintain proper water temperature complete all as specified & as directed. |
| 60 | Supply only Solar Flat Plate Collector (existing size) having made of copper absorber having same as per existing location including connected items as required at site to make it fully funtioning complete all as specified and as directed by Engineer-in-charge. |
| 61 | Supply only gasket set for solar water heater panel suitable for 500 LPD capacity as per existing sample, including other connected items as required at site to make it fully funtioning complete all as specified and as directed by Engineer-in-charge. |
| 62 | S&F in replacement non return valve 20 mm bore for iron pipes complete all as specified and directed by Engineer-in-charge. |
| 63 | M&L rubber hose pipe 20mm dia between hot water tank & collector including dismantling & taking out existing unserviceable rubber hose pipe complete all as specified and as directed. |
| 64 | S & F in repair heating element of capacity 3KW as per existing type including rubber washer , bolts clamps etc. for any type of solar water heater complete all as specifie and as directed by Engineer-in-charge |
| 65 | Supply and fixing in replacement of thermostatic switch (ISI marked) of range 0˚C to 80˚C suitable for solar water heater as per existing sample . |
| 66 | M&L for fabrication of staging for fixing of tank on roof for solar water heater up to 2.5 metre height from roof top, fabricated with mild steel angle, flat, tee etc (using steel section of grade Fe-290 Grade 165) confirming to including nuts, bolts, washers, welding, drilling holes for bolts, painting over all two coat synthetic enamel paint over one coat of primer, and taking down / dismantling of old staging complete all as specified & directed by Engr-in-Charge. |
| 67 | S&F in replacement galvanized iron strip of size 32 x6 mm as earth continuity conductor buried in ground or fixed to wall/floor/ground provided with porcelain insulators space no less than 0.5 mtrs complete all as specified and directed. |
| 68 | S&F in replacement copper strip of size 32 x6 mm as earth continuity conductor buried in ground or fixed to wall/floor/ground provided with porcelain insulators space no less than 0.5 mtrs complete all as specified and directed. |
| 69 | S&F in replacement copper strip of size 20 x3.15 mm as earth continuity conductor buried in ground or fixed to wall/floor/ground provided with porcelain insulators space no less than 0.5 mtrs complete all as specified and directed. |
| 70 | M&L for carrying out brazing to existing earthing strip joint in between earthpit to test point after removing the nut bolt ,scraping the strip,preparing the hole and fix new copper bolt and nut the surface all as specified by Engr-in-charge Note - length of brazing 75mm minimum for jointing of strip. |
| 71 | Material and labour in repairs for electric Welding of existing GI strip of any size, any height (on roof/ on wall) at various places complete all as specified and directed by Engr in Charge. |
| 72 | M& L in repairs for porcelin insulater fixing on wall for supporting the copper strip at distance 45 cm including nut bolt drilling hole etc complete all as specified and directed by Engineer-in-charge. |
| 73 | M & L in repairs for GI funnel and wire mesh for earth pits complete all as specified & directed by Engr in Charge. |
| 74 | Material and labour for Test point terminal block in repairs as made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified & directed by Engr in Charge. |
| 75 | Taking down old broken and damaged earth pit chamber and M & L for construction of new earth pit chamber of size 600 X 600 X 300 mm of PCC 1:2:4 Type B-1including colour of earth pit chamber red/green/yellow/white all as specified and directed by Engineer-in-charge. |
| 76 | M/L air termination single pointed copper rod of 12 mm dia and 300 mm long. |
| 77 | M & L for PCC 1:2:4 with 20 mm grade aggregate including demolation of existing foundation all as specified and as directed by Engineer in charge. |
| 78 | Material and labour in repairs for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground, vertically to a dpeth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not lss than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip 32 x 6mm by means of bolts, nuts, check-nuts and wahsers of galvanised iron and thimbles and of earth wire protected by galvanised iron pipe light grade 40mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh complete 1:3:6 type C-1 using 20mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No 3 of SSR- 2009 (Part-1) |
| 79 | Supply and laying in repair of GI pipes medium grade with fitting laid in trenches/wall /ground surface complete for the 20 mm sizes for eathing pits water connection complete all as specified and as directed. |
| 80 | Material and labour of topup of potassium nitrate (commerical name Kalmi Shora) in the earthing chambers for improvement existing of earthing registance vlaue complete all as specified and as directed. |
| 81 | Material and labour of topup of common salt in the earthing chambers for improvement existing of earthing registance vlaue complete all as specified and as directed. |
| 82 | Material and labour of 20-25 mm thick Kota stone earth pit cover of size 2 ft X 2 ft complete all as specified and as directed. |
| 83 | Material and labour of Iron earth pit cover of size 2 ft X 2 ft complete all as specified and as directed. |
| 84 | Material and labour in repair of bib tap 20 mm dia standered of PTMT any colour high pressure screwed for iron pipe complete all as specified and as directed. |
| 85 | Material and labour for cover of eathing strip for protection against corrosion and damage made of PVC Complete all as specified and directed. |
| 86 | Material and labour for Earthing pit marker /identifier ,size of identifier 30 cmx20 cm board (preferably metallic) fix on the pole height from grnd 60 cm above the grnd and 2.5 cm under the ground, unit identification no to be prefixed with marking no of earthing pits.design of identifier should be diffrent for equipment earthing,power earthing and LA earthing as per directed by eng-in-charge. |
| 87 | Material and labour for painting of earth pit with red/yellow colour Complete all as specified and directed. Please Enable Macros to View BoQ information |