| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in hard/dense soil for foundation, etc. or for laying of pipe line/ cable etc. n exc 10 sqm on plan and getting out complete all as specified and as directed. |
| 2 | Excavation in trenches in soft/disintegrated rock, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for laying of pipe line/ cable etc. n exc 10 sqm on plan and getting out complete all as specified and as directed. |
| 3 | Returning filling in including spreading watering and well raming in layer excedding 25 cm each in any type of soil/rock complete all as specified and directed. |
| 4 | Removing excavated material (Soils/rock) to a distance not exceeding 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed. |
| 5 | S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 50 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 6 | S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 95 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 7 | S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 120 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 8 | S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 185 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 9 | S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 240 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 10 | S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 400 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 11 | M&L for replacement of GI tubing medium grade 80 mm bore for passing through cables laid under the floor, along the wall or along the pole complete all as specified and directed . |
| 12 | Supply & laying double walled corrugated (DWC) HDPE full rounded pipe conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 50 mm inner dia and 63 mm outer dia complete all as directed. |
| 13 | Supply & laying double walled corrugated (DWC) HDPE full rounded pipe conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 75 mm inner dia and 90 mm outer dia complete all as directed. |
| 14 | Supply & laying double walled corrugated (DWC) HDPE full rounded pipe conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 94 mm inner dia and 110 mm outer dia complete all as directed. |
| 15 | S&F in replacement of existing unsv cable joints with straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm to 50 sqmm, 1100 V and testing after jointing complete all as directed. Note:- Rate quoted including necessary excavation, returning filling, removal etc for taking out loop/ cutting of burnt cable for required length for making end joint. |
| 16 | S&F in replacement of existing unsv cable joints with straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 sqmm, 1100 V and testing after jointing complete all as directed. Note:- Rate quoted including necessary excavation, returning filling, removal etc for taking out loop/ cutting of burnt cable for required length for making end joint. |
| 17 | S&F in replacement of existing unsv cable joints with straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 240 sqmm,1100 V and testing after jointing complete all as directed. Note:- Rate quoted including necessary excavation, returning filling, removal etc for taking out loop/ cutting of burnt cable for required length for making end joint. |
| 18 | S&F in replacement MCCB 63 Amps, 415 volts, 50 Hz, 4 pole, 16 KA breaking capacity with thermal magnetic setting including providing suitable size aluminium lugs, speders complete all as specified and directed. |
| 19 | S&F in replacement MCCB 100 Amps, 415 volts, 50 Hz, 4 pole, 16 KA breaking capacity with thermal magnetic setting including providing suitable size aluminium lugs, speders complete all as specified and directed. |
| 20 | S&F in replacement MCCB 160 Amps 415 volts, 4 pole, 36 KA breaking capacity with thermal magnetic setting suitable for VTPN including providing suitable size aluminium lugs, spreaders complete all as specified and directed. |
| 21 | S&F in replacement MCCB 250 Amps 415 volts, 4 pole, 36 KA breaking capacity with thermal magnetic setting suitable for VTPN including providing suitable size aluminium lugs, spreaders complete all as specified and directed. |
| 22 | S&F in replacement MCCB 400 Amps 415 volts, 4 pole, 36 KA breaking capacity with thermal magnetic setting suitable for VTPN including providing suitable size aluminium lugs, spreaders complete all as specified and directed. |
| 23 | S&F in replacement MCCB 630 Amps 415 volts, 4 pole, 50 KA breaking capacity with thermal magnetic setting suitable for VTPN including providing suitable size aluminium lugs, spreaders complete all as specified and directed. |
| 24 | S&F Electrical Insulating mat blue in colour confirming IS:15652-2006 of size 2m x 1m x 2.5 mm thick complete all as specified and directed. |
| 25 | M&L for preparation of old painted surface of HT concrete pole by removing all dirt, dust etc. and painting complete surface including connected accessories with one coat of Apex emulsion paint of approved colour including cross arms/bracing support on poles painted with one coat of Aluminium paint and writing of pole Nos etc. complete all as directed |
| 26 | M&L for preparation of old painted surface of LT concrete pole by removing all dirt, dust etc. and painting complete surface including connected accessories with one coat of Apex emulsion paint of approved colour including cross arms/bracing support on poles painted with one coat of Aluminium paint and writing of pole Nos etc. complete all as directed |
| 27 | M&L for preparation of old painted surface of LT steel tubular pole by removing all dirt, dust etc. and painting complete surface including connected accessories including cross arms/bracing support on poles painted with one coat of Aluminium paint and writing of pole Nos etc. complete all as directed |
| 28 | M&L for preparation of old painted surface of Feeder Pillar box/LT Panel by removing all dirt, dust, making necessary welding of broken parts etc. and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including writing of identification etc all as directed |
| 29 | M&L for PCC 1:3:6 type C-1 ( using 20 mm graded stone aggregate) as in repair of earth pit, cable duct, PCC near GOD and transformer including necessary formwork complete all as specified and directed. |
| 30 | Taking down existing MS articles and S&F new Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including applying of two coats of aluminium paint over a coat of red oxide primer complete all as directed. |
| 31 | Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3 mm thick CRCA sheet powder coated with front openable with suitable cable chamber and front side double shutters with locking arrangement, panel base of angle iron 50x50x6 mm upto 60 cm height for ground level, 433 volts, 3 phase, 4 wire system. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with Aluminium busbar of size 50 x 10 mm. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation 0.45 mtr above floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-INCOMING MCCBa) 350 Amp 4 pole MCCB 36 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 01 Nos.OUTGOING MCCBa) 160 Amp 4 pole MCCB 25 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 03 Nos. b) 100 Amp 4 pole MCCB 25 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 03 Nos. c) Space for spare MCCB/MCBMetering:a) AC digital voltmeter 0-500 volts Size 4\\"X4\\" with 3 Ph selector switch-01 Nosb) 0-500 digital Amp meter with suitable Size 4\\"X4\\" with 3 Ph selector switch- 01 No.c) LED Indicating lamps RYB set of three -01 SetsThe manufacture shall submit a copy of TESTREPORT of CPRI approved. |
| 32 | Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3 mm thick CRCA sheet powder coated with front openable with suitable cable chamber and front side double shutters with locking arrangement, panel base of angle iron 50x50x6 mm upto 60 cm height for ground level, 433 volts, 3 phase, 4 wire system. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with Aluminium busbar of size 25 x 6 mm. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation 0.45 mtr above floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-INCOMING MCCBa) 350 Amp 4 pole MCCB 36 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 01 Nos.OUTGOING MCCBa) 160 Amp 4 pole MCCB 25 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 02 Nos. b) 100 Amp 4 pole MCCB 25 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 02 Nos. c) Space for spare MCCB/MCBMetering:a) AC digital voltmeter 0-500 volts Size 4\\"X4\\" with 3 Ph selector switch-01 Nosb) 0-500 digital Amp meter with suitable Size 4\\"X4\\" with 3 Ph selector switch- 01 No.c) LED Indicating lamps RYB set of three -01 SetsThe manufacture shall submit a copy of TESTREPORT of CPRI approved. |
| 33 | Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3 mm thick CRCA sheet powder coated with front openable with suitable cable chamber and front side double shutters with locking arrangement, panel base of angle iron 75x75x8 mm upto 60 cm height for ground level, 433 volts, 3 phase, 4 wire system. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with Aluminium busbar of size 80 x 10 mm. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation 0.45 mtr above floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-INCOMING MCCBa) 630 Amp 4 pole MCCB 36 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 01 Nos.OUTGOING MCCBa) 250 Amp 4 pole MCCB 25 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 02 Nos. b) 160 Amp 4 pole MCCB 25 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 03 Nos. c) Space for spare MCCB/MCBMetering:a) AC digital voltmeter 0-500 volts Size 4\\"X4\\" with 3 Ph selector switch-01 Nosb) 0-500 digital Amp meter with suitable Size 4\\"X4\\" with 3 Ph selector switch- 01 No.c) LED Indicating lamps RYB set of three -01 SetsThe manufacture shall submit a copy of TESTREPORT of CPRI approved. |
| 34 | M&L taking out old earthing and providing new earthing complete with galvanised steel plate electrode 600 mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron strip 25 x 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl. excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing complete all as specified an directed.Note:- The unit rate includes the cost of GI pipe medium grade for protection of earth wire and earth strip upto 7.5 M. |
| 35 | S&F in replacement aluminium lugs suitable for cable size 25 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 36 | S&F in replacement aluminium lugs suitable for cable size 50 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 37 | S&F in replacement aluminium lugs suitable for cable size 95 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 38 | S&F in replacement aluminium lugs suitable for cable size 150 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 39 | S&F in replacement aluminium lugs suitable for cable size 185 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 40 | S&F in replacement aluminium straight through lugs suitable for cable size 35 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 41 | S&F in replacement aluminium straight through lugs suitable for cable size 95 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 42 | S&F in replacement copper lugs suitable for cable size 95 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 43 | S&F in replacement on load changeover switch 250 A, 4 pole complete fixed to sheet metal enclouser/ MCB DB with all necessary fixing arrangements complete all as specified and directed. |
| 44 | S&F in replacement on load changeover switch 400 A, 4 pole complete fixed to sheet metal enclouser/ MCB DB with all necessary fixing arrangements complete all as specified and directed. |
| 45 | S&F in replacement sheet metal enclosures suitable for MCCB, 4 pole 160 Amp to 400 Amp complete all as specified and directed. |
| 46 | M & L for filling and spreading aggregate using 40 mm grade trap stone aggregate around 4 pole , 2 pole structure and transformer etc. complete all as specified and directed. Please Enable Macros to View BoQ information |