| 1 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for route of cable and getting out complete all as specified and as directed by the Engineer-in-Charge. |
| 2 | Returning, filling in soft/loose soil including spreading, leveling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engineer-in-Charge. |
| 3 | Removing of surplus soil to a distance not exc. 50 meter and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by the Engineer-in-Charge. |
| 4 | M/&L for stone slab 40 to 50 mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 30 cm wide and not less then 50 cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10 mm over sand cushioning all as specified and directed by Engr-in-Charge. |
| 5 | supply and laying of Local tibba dry sand cushioning and cover (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) for protection of cable, material and labour complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Supplying and Fixing/connecting for service connection/ Garden light connection, 1100 volts grade heavy duty Cable PVC insulated Aluminium conductor, Three core cable circular of sizes 16 Sqmm 2 Core complete all as Specified and directed. |
| 7 | ----Ditto---- above item no- 1 but sizes 10 Sqmm 2 Core. |
| 8 | ----Ditto---- above item no- 1 but sizes 6 Sqmm 2 Core. |
| 9 | ----Ditto---- above item no- 1 but sizes 4 Sqmm 2 Core. |
| 10 | Supply only in replacement of control wiring with single core 2.5 sqmm 3 core , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts complete all as specified and directed (Note : Two run of wire with PVC conduit will be considered as one Length.) |
| 11 | S&F IN repair of MCCB 4 Pole , 415 V, Adjustable type,160 Amps with breaking capacity 36 KA material and labour complete all as specified and as directed by Engineer-in-Charge.. |
| 12 | S&F IN repair of MCCB 4 Pole , 415 V, Adjustable type,125 Amps with breaking capacity 36 KA material and labour complete all as specified and as directed by Engineer-in-Charge.. |
| 13 | Supply and fixing in repair of post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 14 | Supply and fixing in repair of post top lantern LED type 40/45 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 15 | Supply and fixing in repair of round shape bollard 10 Watt integral decorative with ip 66 degree of protection of capacity 10 watt LED with all accessories pole, foundation , complete errect/fixed/mount properly at directed place with reqd fixing/mounting arrangement and connecting/testing complete all as specified by Engr-in-Charge. Make- Havells |
| 16 | Supply and fixing in repair of 45 W integral decorative with ip 66 degree of protection of capacity 45 watt LED with all accessories made with casted iron ISI approved pole dia 40 mm height 7 feet, foundation , complete errect/fixed/mount properly at directed place with reqd fixing/mounting arrangement and connecting/testing complete all as specified by Engr-in-Charge. |
| 17 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified by Engr-in-Charge.make- havells |
| 18 | Supply and fixing LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified by Engr-in-Charge. |
| 19 | Supply and fixing in replacement GI pipe light grade 40 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/ceiling / along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge. (Note :- Necessary excavation, earth work and same work shall be measured and paid for separately.) |
| 20 | Supply and fixing in repair driver for post top 20 W ,240 volt,50 hz,IP-65 round shaped , complete all as specified and directed. Make: Crompton Cat Part No-LPTH-20-CDL (as per sample) |
| 21 | Supply and fixing in repair driver for post top 40 W ,240 volt,50 hz,IP-65 round shaped , complete all as specified and directed.Make: Crompton Cat Part No-LPTH-40-CDL (as per sample) |
| 22 | Supply and fixing in repair LED Plate 20 W ,240 volt,50 hz,IP-65 complete all as specified and directed. |
| 23 | Supply and fixing in repair LED Plate 10 W ,240 volt,50 hz,IP-65 complete all as specified and directed. |
| 24 | Supply and fixing LED Outdoor Under water Fountain RGB Light 12 watt with IP 68 protection, complete all as specified by Engr-in-Charge. |
| 25 | Supply and fixing in repair street light bracket made of 32 mm GI pipe , 1.2 mtr lenght fixed with two nos of clamp , nut and bolts complete all as specified and directed. |
| 26 | Material and labuor for earthing complete with Galvanized Steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected & including GI wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected by 15mm dia GI Pipe (light grade). Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers & 15cm of widht all aurround of earth plate including 20mm dia GI light grade pipe for watering and including funnel, wire mesh, necessary earth work in any type of soil, Pre-cast RCC cover duly re inforced with 8mm dia TMT Bar @150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab, Earth Pit of PCC (1:3:6) type C2 (using 20mm graded crushed store aggrgate) complete all as specified and as shown in electrical plate No-3 of SSR Part-I including testing on completion. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. |
| 27 | Supply and replace sheet metal enclosure distribution board for 240 volts, 2 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete including taking out old all as directed. |
| 28 | Supply and replace Sheet metal enclosure distribution board TPN, 415 volts, 4 way Horizontal/vertical type as per site requirement, double door type, 200 Amps rated neutral copper bus bar for housing MCBs and including provision for fixing TPN MCB as incommer, DB fixed flush or in wall surface including making good to damaged surface of wall to match with existing specification complete including taking out old all as specified all as specified and directed. Note : MCB SP/SPN/TPN will measured and paid separately under relavant item. |
| 29 | Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. |
| 30 | M&L for MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. |
| 31 | M&L for MCB TPN/FP, 40 to 100 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. |
| 32 | Road cutting of any size and any type for laying and excavation of cable and making good to the damaged road including surface finish of road with PCC or cement work or mortar as required all as specified all as specified and directed. |
| 33 | Supply and fixing LED Under water Swimming pool Light, Recessed/Conceal mounting, RGB Light 12 watt with IP 68 protection, complete all as specified by Engr-in-Charge. |
| 34 | Supply and fixing RGB LED Flood light with cast aluminum housing, toughened glass cover, high efficient LED, IP65/66, 10KV SPD,and wired with all accessories, complete all as specified by Engr-in-Charge. |
| 35 | Supply and fixing in replacement 20mm PVC Conduit complete with fittings, complete all as specified and directed. |
| 36 | Supply only in replacement of LED Bulb 12 Watt,complete all as specified and directed |
| 37 | Supply only in replacement of LED Bulb 09 Watt,complete all as specified and directed |
| 38 | M&L for PCC Foundation for garden light pole of size 450mm x 450mm x 600mm deep, including excavation, centering, concreate, backfilling, compaction, and disposal of surplus earth complete all as specified and directed. |
| 39 | Supply and fixing in Replacement GI Pipe 40mm dia for garden light and Post top Light complete all as specified and directed. Please Enable Macros to View BoQ information |