| 1 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified. |
| 2 | Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, precast concrete articles etc but excluding ashlar facings, dressed stone works and ,complete all as specified. |
| 3 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified. |
| 4 | M&L for 15 mm thick plastering in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement) complete all as specified. |
| 5 | M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint on walls. complete all as specified. |
| 6 | M&L for preparation of newly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality complete all as specified |
| 7 | M&L for brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified. |
| 8 | M&L for Providing precast cement concrete louvres and jallies, 25 mm thick type B-0 1:2:4 (using 12.50 mm graded stone aggregate (measured solid), including all mouldings but excluding frame , set in cement mortar (1:6) complete all as specified and as directed. |
| 9 | M&L for Providing precast cement concrete type B-1 1:2:4 (using 20 mm graded stone aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar 1:4 complete. |
| 10 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition ) of any description in any position not specifically provided complete complete all as specified. |
| 11 | M&L for providing reinforced cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified. |
| 12 | M&L for mild steel TMT bars 10mm dia and over. Cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 13 | M&L for mild steel TMT bars 5 mm dia and over, upto and including 10 mm dia as in stirrups, cut to length, bent to shape required including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and as directed. |
| 14 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 5 cm but n exc 10 cm wide rough finished complete all as specified. |
| 15 | Formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work not exceeding 200 mm thick rough finished in flat surface complete all as specified. |
| 16 | M&L for cement concrete type C-1 1:3:6 (using 20 mm graded stone aggregate) as in surface channel and drains etc complete all as specified. |
| 17 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. |
| 18 | S&F SFRC manhole/drain cover 75 mm thick factory made with plain surface as per requirement including 75 X1.5 mm flat iron frame all around the cover complete all as specified and as directed. |
| 19 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 20 | S&F mild steel in framed work as in doors or steel gates of angle or other section with gusset plates, rails, braces, or tubular section, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe- 290.Gde-E-165 complete all as specified. |
| 21 | S&F 1.60 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required. |
| 22 | S&F Mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes for notching of wire, etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified. |
| 23 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified. |
| 24 | M&L for excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft and loose soil complete all as specified. |
| 25 | M&L for cement concrete type B-2, 1:2:4 (40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified. |
| 26 | S&F in repair Galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc comlete all as specified (each line wire to be measured). |
| 27 | S&F in repair re-inforced punched concertina coil of 600 mm dia (chrome razer or blade wire) with barbed tape of 0.50 mm thick galvanised steel steel sheet or core wire of dia 2.5mm of high tensile steel wire including galvanised mild steel staple/clips for tying at crossing etc complete all as specified. |
| 28 | Dismantling fencing wire mesh, any type complete all as specified and as directed. |
| 29 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire. |
| 30 | Supplying only Chain link MS galvanised fencing, any size or type complete all as specified. |
| 31 | S&F 11 to 15 mm dia of shank mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other end,or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut but length exc 5 cm and n exc 10 cm long all as specified. |
| 32 | S&F Mild Steel round bar 10 dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips for Gd.I, Fe-432 (Part I) complete all as specified. |
| 33 | Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified & directed. |
| 34 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws as specified & directed. |
| 35 | S&F in repair steel rolling shutter of thickness 1.00 mm without ball bearing as specified including top cover , anchoring rod , hasp and staple and one shop coat of primer erected in position, gear operated type with bevel gear box and crank handle complete all as specified. |
| 36 | S&F Ball bearing for rolling shutters complete all as specified. |
| 37 | M&L for prepration of new Steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified |
| 38 | M&L for 75 mm thick cement concrete type D-2 1:4:8 with )using 40 mm graded stone aggregates) as in sub base of flooring etc complete all as specified. |
| 39 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified |
| 40 | M&L for providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved , design & pattern as in footpath , parks , lawns,drive ways or light traffic parking etc. of required strength , thickness & size/shape, made by table vibratory method using PU mould , laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand , compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling joints with sand andcutting of paver block as per required size and pattern,finishing and sweeping extra sand. Complete all as specified |
| 41 | M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified. |
| 42 | M&L for 22-25 mm thick chequered designer coloured tiles (matt/glass finish), size, colour and shape as approved by GE, set and jointed in neat cement slurry and pointed with coloured cement to match etc complete all as specified as directed. |
| 43 | M&L for 100 mm thick cement concrete (1:2:4) type B-1 with using (20 mm graded crushed stone aggregates) as in Hardstanding complete all as specified. |
| 44 | M&L Forming contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound grade 'A'. Complete all as speicified. |
| 45 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 46 | M&L for cement concrete type B0 1:2:4 (using 12.50 mm graded stone aggregate) as in coping benching, gola, slightly rounded and similar items complete all as specified and as directed. |
| 47 | Removing demolished materials / debries exc. 250 m but n exc. 500 m and depositing where directed. Please Enable Macros to View BoQ information |