| 1 | M&L Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose complete all as specified and as directed. |
| 4 | Demolition of cement concrete (un-reinforced ) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 5 | M&L Plain Cement Concrete type C2 1:3:6 (using 40 mm graded crushed stone aggregate) in foundations,filling and mass concrete complete all as specified and as directed |
| 6 | M&L Plain Cement Concrete type B1 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping complete all as specified and as directed |
| 7 | Demolition of brickwork built in cement mortar including all quions, arches, pillars etc complete all as specified and as directed. |
| 8 | M&L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and as directed |
| 9 | All as per item No.8 above, but except bricks complete all as specified and directed.[Note :- Serviceable bricks obtained from dismantling item No 7 here-in-before] |
| 10 | M&L Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed. |
| 11 | M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces Cement mortar 1:6 finished even & smooth without using extra cement complete all as specified and as directed. |
| 12 | Dismanting post of struts (wood,steel or RCC) any section,including taking out embedded portion in concrete and making good the disturbed ground complete all as specified and as directed. |
| 13 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 14 | S&F for MS work like posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe - 290 grade E-165 complete all as specified and as directed. |
| 15 | Dismantling of chain link fencing of any type any size complete all as specified and as directed. |
| 16 | Supply only 75x75 mm mesh size Chain link MS galvanisd fencing, any size or type complete all as specified and as directed. |
| 17 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed. |
| 18 | Dismanting of Barbed wire or any type and size complete all as specified and as directed. |
| 19 | Restraining & resecuring including making good staples etc old galvaned barbed wire complete all as specified and as directed. |
| 20 | S&F in repair galavanized. 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and galvanized coating of steel wire shall confirm to the requirement as laid down for medium coated wire in IS 4826 and straining and fixing to any type of standard rails staining bolts, including securing or tying at crossings with and provision of galvanized mild steel pins etc complete all as specified and as directed. (Each line wire to be measured) |
| 21 | M&L Mild steel TMT bars 8mm to 10mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and as directed. |
| 22 | M&L preparation of new or previously untreated steel and Iron surface of any description, not otherwise described exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 23 | M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick walls or concrete surfaces in two layers (10mm & 5mm) mixed with water proofing compound by weight of cement or as per manufacturer instructions, finished even & smooth without using extra cement all complete all as specified and as directed. Note. Liquid water proofing compound will be measured and paid separtely. |
| 24 | Surface excavation n. exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed. |
| 25 | Supply only integral water proofing compound complete all as specified and as directed. |
| 26 | M&L RCC nominal mix type B1 (1:2:4) using 20 mm graded stone aggregate as in slabs support on walls beam, & column in floors, roof, lobby, balcony, deck slab and in shelves and the like complete all as specified and as directed.Note: Reinforcement shall be measured and paid separatly under relevant item of this schedule. |
| 27 | M&L 5mm dia & over upto 10mm dia as in stirrups, spaceras and binders with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and as directed. |
| 28 | M&L for hardcore of gauge n. exc 63mm, deposited, broken stone or boulder spread and evelled in layers n. exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 29 | M&L for Providing, cement concrete Type B1 1:2:4 using 20 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 30 | M&L extra for forming fair finished drain or channel 30cm inner girth in cemeny concrete using extra cement including forms, moulds mitred/ stopped ends etc complete all as specified and as directed. |
| 31 | M&L 100mm thick PCC 1:2:4 type B2 ( using 40mm graded aggregate) as in floors, finished even & smooth without using extra cement complete all as specified and as directed. |
| 32 | M&L preparation of new plaster surfaces of wall and applying three coat of white wash complete all as specified and directed. |
| 33 | M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200mm thick (Horizontal or sloping) flat, rough finished surfaces of concrete complete all as specified and as directed. |
| 34 | M&L Formwork to edges of concrete, flat tread break in floors, window cills, concrete railling, opening in concrete wall, floor and roofs n. exc 20cm width and sides of RCC/PCC bend in wall horizental and slopping work etc exc 10cm and n. exc 20cm rough finish surfaces of contract complete all as specified and as directed. |
| 35 | M&L RCC nominal mix type B1 (1:2:4) using 20 mm graded stone aggregate as in well steining and well curbs complete all as specified and as directed.Note: Reinforcement shall be measured and paid separatly under relevant item of this schedule. |
| 36 | M&L PCC 100mm thick type B-2 (1:2:4), 40mm thick graded aggregate finishing cement surface smooth and even without using extra cement and spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and as directed. |
| 37 | M&L moorum/red bajri filling in floors or pavings, laid in layers n. exc 15cm thick, spread leveled nraammed including watering complete all as specified and as directed. |
| 38 | M&L PCC 100mm thick type C-2 (1:3:6), 40mm thick graded aggregate finishing cement surface smooth and even without using extra cement and spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and as directed. |
| 39 | Rolling & consolidation of formation surface with 8 to 12 tonne with power roller complete all as specified and as directed. |
| 40 | M&L 150mm thick spreed thickness soling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradien and camber complete all as specified and as directed. |
| 41 | M&L PCC 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in path /steps laid with and and finishing the surface even and rough to receive the topping layer or tiling complete all as specified and as directed. |
| 42 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 43 | M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 44 | M&L 100mm thick Cement concrete type C2, 1:3:6 (40mm graded aggregate) as in sub base of floor finished even and rough complete all as specified and directed. |
| 45 | Forming 12mm thick expansion joints of 150mm concrete slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, grade 'A' complete all as specified and as directed |
| 46 | Forming contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and as directed |
| 47 | M&L for PCC type B-2, (1:2:4) (40mm graded stone aggregate) as surface channels and drain complete all as specified and as directed Please Enable Macros to View BoQ information |