| 1 | S & F for UPVC 200 mm square 3 mm thick Euro Guard rain water harvesting roof Gutter pipe including bend,stopper,Elbow/corner/end drop and fixing with manufacturar brackets to adjucent wall/wooden frame with all fitting and necessary form work and making good of existing surface up to 5m height,complete all as specified and as directed. |
| 2 | S & F for UPVC pipe SCH-40 of 200 mm dia single socketed in any length with rubber ring joints fixed to wall/laid in trenchs including all fittings like bends,elbows,brackets etc.,complete all as specified and as directed. |
| 3 | Dismantling of single layer mangalore pattern roofing tiles complete all as specified and as directed. |
| 4 | M&L for roof tile, Mangalore pattern, interlocking at side joints, laid dry all as specified and as directed |
| 5 | S&F Pre-painted galvalumealuminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/cladding to wall,eve sheets, fixed with self tapping screws all as specified and as directed. |
| 6 | Excavation in trenches n.exc 1.50m wide and n.exc 1.50 m in depth for foundation etc, n.exc 10 sqm on plan and getting out in hard/dense soil all as specified and as directed. |
| 7 | All as per item no.6 above but in soft/loose soil all as specified and as directed |
| 8 | Excavating over area not exceeding 1.50 m deep and gettiing out in Hard/Dense soil. all as specified and as directed |
| 9 | All as per item no 8 above but exe 1.5 m but n exc 3.m depth all as specified and as directed |
| 10 | Returning filling in including spreading levelling, watering and well ramming in layers not exceeding 25 cm in hard / dense soil.all as specified and as directed |
| 11 | All as per item no.10 above but in soft/loose soil all as specified and as directed |
| 12 | M&L for PCC 1:3:6 type C2 40 mm graded aggregate Cement concrete in foundations, filling and mass-concrete all as specified and as directed |
| 13 | M&L for Pre cast cement concrete (1:3:6) Type C1 using 20mm graded stone aggregate block masonry set in cement mortar 1:6 with solid blocks exc,10cms in width complete all as specified and as directed |
| 14 | Rendering 15mm thick on fair face of brick or concrete surfaces in cement mortar (1:6) including finishing the surface even and smooth with out using extra cement complete all as specified and as directed |
| 15 | Rendering 15mm thick on fair face of brick or concrete surfaces in cement mortar (1:4) including finishing the surface even and smooth with out using extra cement with WPC complete all as specified and as directed. Note: WPC shall be measured and paid separately |
| 16 | Supply only Water proofing compound of approved make all as specified and as directed |
| 17 | M&L Preparation of new plastered surfaces on walls and applying two coats of cement base painting including a coat of alkali resistant primer all as specified and as directed |
| 18 | M&L for filling brick bats in soakage wells complete all as specified and as directed. |
| 19 | M&L for Bamboo mat laid over brick bats in soakage wells complete all as specified and as directed. |
| 20 | M&L for precast RCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in cover slab over drain, man hole etc and set in cm 1:6 including necessary form work and moulds complete as specified and as directed. |
| 21 | M&L for Loose filling with broken stone or boulders of gauge 40 to 80 mm as filter media all as specified and as directed. |
| 22 | M & L for TMT bar bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed |
| 23 | M & L for Hardcore of broken stone or boulders of gauge not exc. 63mm deposited,spread & levelled in 15cms thick, watered & rammed to a true surface all as specified and as directed |
| 24 | M& L for 100mm thick PCC type C-2(1:3:6) using 40mm graded stone aggregate as in sub base for top finish of any description etc including finish the surface even and rough to receive the top finish complete all as specified and as directed |
| 25 | M&L for chequered cement concrete tiles of size 20cmx20cmx 25mm thick ,set ,jointed and pointed in neat cement slurry in floors with grey cement and pigments of required colour over 20mm thick screed bed in CM (1:6) completeall as specified and as directed |
| 26 | M&L for PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in bed for drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and directed |
| 27 | M&L for laying of DWCPE sewage pipes 150 mm dia including jointing,sealing of joints, fittings etc complete with collars all as specified and as directed |
| 28 | Surface dressing n exc 15 cm deep and getting out soft/loose soil all as specified and as directed |
| 29 | Excavating over area not exceeding 1.50 m deep and gettiing out in Hard/Dense soil.all as specified and as directed |
| 30 | All as per item no.29 but exe 1.5 m but nexc 3.m depth all as specified and as directed |
| 31 | M&L for PCC 1:3:6 type C2 40 mm graded aggregate as in foundations, filling and mass-concrete etc all as specified and as directed |
| 32 | M&L for Reinforced cement concrete (Design mix) RCC M30 20 mm gragded aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete all as specified and as directed |
| 33 | M&L for Reinforced cement concrete (Design mix) RCC M30 20 mm gragded aggregate in Walls, retaining walls, basement walls and the like; any thickness; above top of footings; including attached pilasters and buttresses all as specified and as directed |
| 34 | M&L for Reinforced cement concrete (Design mix) RCC M30 20 mm gragded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like all as specified and as directed |
| 35 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, plith protection ; and similar work; vertical or to batter, flat fair finish surface all as specified and as directed |
| 36 | M&L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to better, flat fair finish surface all as specified and as directed |
| 37 | M&L form work to soffits of suspended slabs such as roof slabs, floor slabs, landing slabs and similar works not exc 200 mm thick for flat and fair finished surface complete all as specified and as directed |
| 38 | M & L CRS TMT bar bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed |
| 39 | S&F 20 mm dia MS rungs in to the wall bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; will ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde -165 all as specified and as directed |
| 40 | M&L for 40mm thck 1:2:4 type B-0, PCC flooring finished even and smooth with using extra cement all as specified and as directed |
| 41 | M&L for Hardcore of broken stone or boulders of gauge not exc. 63mm deposited,spread & levelled in 15cms thick, watered & rammed to a true surface all as specified and as directed |
| 42 | M&L for PCC 1:3:6 type C1 20 mm gragde aggregate 75 mm thick in plinth protection, plith course ,kerbs as directed. Finishing even and smooth without using extra cement all as specified and as directed |
| 43 | M&L for Plastering 05 mm thick CM 1:3 on fair faces of brick work or concrete surfaces finihed even and smooth with out using extra cement all as specified and as directed. |
| 44 | M&L for Plastering 12mm thick CM 1:3 on fair faces of brick work or concrete surfaces finihed even and smooth with out extra cement and using water proofing compound. Note: WPC will be measured and paid separately |
| 45 | M&L for Plastering 22mm thick in two caots 12 and 10 mm CM 1:3 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement and using WPC all as specified and as directed. Note: WPC will be measured and paid separately |
| 46 | Supply only Water proofing compound of approved make all as specified and as directed |
| 47 | S/F PVC water bar 150mm wide and 8mm thick all as specified and as directed |
| 48 | M&L Preparation of new plastered surfaces and applying two coats of cement base painting including a coat of alkali resistance primer all as specified and as directed |
| 49 | M&L Preparation of new plastered ceiling surfaces and applying two coats of cement base painting including a coat of alkali resistance primer et complete all as specified and as directed |
| 50 | Supply, installation, testing and commissioning of Open well Submersible Pump1.5 HP, Single Phase, 210 Volts, with Control Panel Size 32mm X25mm, having capacity of withstand wide voltage fluctuations from 160 to 240 volts all as specified and as directed |
| 51 | Supply and lay submersible copper conductor cable 2 core 1.5 Sqmm 1100 volts multistranderd PVC insulated weather proof, sheathed heavy duty ISI marked cable complete all all as specified and as directed. |
| 52 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A , 240 V C Series with Breaking capacity 10KA all as specified and as directed |
| 53 | Supply Laying Galvanised Pipe 25mm dia medium grade with necessary fittings and fixtures including testing of joints etc complete all as specified and as directed. |
| 54 | Supply Laying Galvanised Pipe 20mm dia medium grade with necessary fittings and fixtures including testing of joints etc complete all as specified and as directed. |
| 55 | Supply and fix for gun metal gate valve 25mm dia with iron wheel head screwed both ends, ISI marked, fixed to GI pipe complete all as specified and as directed |
| 56 | Supply and fix for gun metal gate valve 20mm dia with iron wheel head screwed both ends, ISI marked, fixed to GI pipe complete all as specified and as directed |
| 57 | Removing excavated surplus soil to a distance exceeding 250 mtr and but n exc 500 m out side the MD land and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and as directed |
| 58 | Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and as directed . |
| 59 | Note: Please note that if rate quoted for similar items are different, the lowest rate quoted for item shall be only considered for payments of works Please Enable Macros to View BoQ information |