| Sl. No. | Item Description |
| 1 | Taking down old unserviceable LT UG cable from any description (trenches, walls, ceilings., etc) from various locations, Supply and Laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 10 Sq mm, 2 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified and directed by Engr-in-charge. |
| 2 | All as per item No 01 here in before but of size 4 core 10 sqmm |
| 3 | All as per item No 01 here in before but of size 4 core 16 sqmm |
| 4 | All as per item No 01 here in before but of size 4 core 25 sqmm |
| 5 | All as per item No 01 here in before but of size 3 1/2 core 35 sqmm |
| 6 | All as per item No 01 here in before but of size 3 1/2 core 50 sqmm |
| 7 | All as per item No 01 here in before but of size 3 1/2 core 70 sqmm |
| 8 | All as per item No 01 here in before but of size 3 1/2 core 95 sqmm |
| 9 | All as per item No 01 here in before but of size 3 1/2 core 120 sqmm |
| 10 | All as per item No 01 here in before but of size 3 1/2 core 185 sqmm |
| 11 | All as per item No 01 here in before but of size 3 1/2 core 240 sqmm |
| 12 | Note item No 01 to 11 :- (a) Excavation, Concrete cable protection cover, pipe, PCC work for road crossing/hard standing and Sand for cushioning will be measured and paid separately.(b) Cost of glands, aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape), new nut, bolt and washers of required size/description are deemed to include in this rate. |
| 13 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil getting out and leveling of bottom surface to required level for laying UG cable/erection of poles complete all as specified and directed by Engr-in-charge. |
| 14 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft/disintegrated rock getting out and leveling of bottom surface to required level complete all as specified and directed by Engr-in-charge. |
| 15 | Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wall for laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. |
| 16 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed by Engr-in-charge. |
| 17 | Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and directed by Engr-in-charge. |
| 18 | Supply and lay Double walled corrugated pipe (DWC ) heavy duty 40 mm dia for cable protection as a guard pipe including required accessories etc. complete as specified and directed. |
| 19 | All as per item No 17 here in before but of size 63 mm dia |
| 20 | All as per item No 17 here in before but of size 90 mm dia |
| 21 | All as per item No 17 here in before but of size 120 mm dia |
| 22 | Supply and fix in repairs LT heat shrinkable Straight through cable Jointing kit, complete with jointing material and accessories suitable for 4 core XLPE armoured Aluminium conductor cable of size 10 to 16 sqmm complete all as specified and directed by Engr-in-charge. |
| 23 | All as per item No 21 here in before but of size 4 core 25 to 50 sqmm |
| 24 | All as per item No 21 here in before but of size 3.5 core 70 to 120 sqmm |
| 25 | All as per item No 21 here in before but of size 3.5 core 150 to 185 sqmm |
| 26 | All as per item No 21 here in before but of size 3.5 core 240 sqmm |
| 27 | Material and labour for fault finding of LT cables of size 35 to 95 sqmm 3.5/4 core and any length with fault detective machine by thumbing method and suitable voltage and all as per manufactures instructions including providing straight through joint and additional cable of same existing size suitable to site requirement complete all as specified and directed by Engr-in-charge. Note : cable joint and cable shall be measured and paid separately under relevant item of Sch 'A' |
| 28 | Material and labour for fault finding of LT cables of size 120 to 240 sqmm 3.5/4 core and any length with fault detective machine by thumbing method and suitable voltage and all as per manufactures instructions including providing straight through joint and additional cable of same existing size suitable to site requirement complete all as specified and directed by Engr-in-charge. Note : cable joint and cable shall be measured and paid separately under relevant item of Sch 'A' |
| 29 | Supply and fix in repairs HT/LT MS cable route indicator 4\\" dia fixed with two Nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the ground including necessary earth work complete all as specified and directed by Engr-in-charge. |
| 30 | Supply & Fix Air circuit beaker 4 Pole, 415 V, Manual Draw out type with microprocessor release of capacity 630 Amps including proper fitting arrangements matching with existing ACB |
| 31 | Supply & Fix Air circuit beaker 4 Pole, 415 V, Manual Draw out type with microprocessor release of capacity 800 Amps including proper fitting arrangements matching with existing ACB |
| 32 | Supply & Fix Air circuit beaker 4 Pole, 415 V, Manual Draw out type with microprocessor release of capacity 1250 Amps including proper fitting arrangements matching with existing ACB |
| 33 | Supply and fix in repairs Energy efficient LED street Light 35 Watts unsheathed wire multistranded from LT over head line to the connector of fitting, connection wires not to be less than 2.5 metre in length duly run through GI bracket complete 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-charge. |
| 34 | Supply and fix in repair changeover switches on load changeover switches 4 pole 400 Amps in sheet steel enclosure with enclosure, including necessary spreaders/cable lugs/gland/nut, bolt and washers if required complete all as specified and directed by Engr-in-charge. |
| 35 | All as per item No 33 here in before but of capacity 320 A 4 pole 415 Volts |
| 36 | All as per item No33 here in before but of capacity 200 A 4 pole 415 Volts |
| 37 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 40A to 63 Amps with breaking capacity 16 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. |
| 38 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 100 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. |
| 39 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 125 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. |
| 40 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 160 Amps with breaking capacity 36 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. |
| 41 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 200 Amps with breaking capacity 36 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. |
| 42 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 250 Amps with breaking capacity 36 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. |
| 43 | Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 400 Amps with breaking capacity 36 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge. |
| 44 | Material and labour for preparation of old cement coated surface, cleaning the surface of the RCC LT/Street light pole above the ground level to top of the pole including coping area (if provides) with one coat of ACC exterior Emulsion paint over a coat of cement primer after preparation of surface including 12 cm black paint around the pole and alluminium paint for Iron cross arms channel/light bracket etc, including writing of pole number (MES........) complete all as specified and directed by Engr-in-charge. |
| 45 | Material and labour for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-in-charge. |
| 46 | Material and labour for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed by Engr-in-charge including demolish existing earth pit taking out old materials. |
| 47 | Material and labour for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-in-charge. |
| 48 | Supply and fix LED Bollard light fitting 8W IP 65 Cone series acts as an imposing street furniture. The elegant yet minimalistic design acts a silent observer and giving light, diffuser at the upper portion adds functional value into landscape environment |
| 49 | Supply and fix in repairs LED post top lantern made in die-cast aluminium housing with decorative clear opal acrylic diffuser with white powder coated aluminium reflector IP-65 protection of 40 watts capacity and including connections service wire with 3 run of 2.5 Sq mm aluminium unsheathed multistranded wire complete all as specified and directed by Engr-in-charge. |
| 50 | Supply and fix in repairs Energy efficient LED street Light 120 Watts unsheathed wire multistranded from LT over head line to the connector of fitting, connection wires not to be less than 2.5 metre in length duly run through GI bracket complete 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-charge. |
| 51 | All as per item No 49 here in before but of capacity 100 watts complete all as specified and directed by Engr-in-charge. |
| 52 | All as per item No 49 here in before but of capacity 70 watts complete all as specified and directed by Engr-in-charge. |
| 53 | Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-Charge. |
| 54 | Supply and fixing LED flood light 210/250 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-Charge. |
| 55 | Supply and fix in repairs Street light bracket made out of GI tubing 40 mm dia of approx 1.2 mtr length, light grade bend to shape suitable for security/street light/Pigmi light fittings with necessary fixing arrangements by using GI flat of 40 x 6 mm size including nut, bolt, washers etc complete all as specified and directed by Engr-in-charge. |
| 56 | Supply and fix in repairs Street light bracket made out of GI tubing 25 mm dia, light grade bend to shape of approx length 1.0 mtr long suitable for security/street light/Pigmi light fittings with necessary fixing arrangements with one coat of red oxide and two coats of synthetic enamel paint including nut, bolt, washers etc complete all as specified and directed by Engr-in-charge. |
| 57 | Supply & Fixing sheet moulding compound junction box (SMC) of OD 280 x 170 x 130 & ID 240 x 130 x 110 suitable for terminating 2 Nos 4 x 6/10/16 Sqmm UG cable including one in Nos MCB SP 4/5 Amp including cable glands of 2 Nos, and two way connector 1 No, including MS Clamp, nut, bolt and washer, including dismantling old one complete all as specified and directed. |
| 58 | Supply and fix in repairs Galvanised Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete including taking down / dismantling the old items complete all as specified and directed by Engr-in-charge. |
| 59 | Dismantling of existing old unserviceable ACSR of any size from any description, material and labour for providing new ACSR conductor all as specified and directed including stringing through existing RCC poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc complete of different sizes complete all as specified and directed by Engr-in-charge. (Note : Rates for new AAC for binding purpose is included in this rate.) |
| 60 | Supply and fix in repairs Pin type porcelain vitreous, brown of white insulator to suit 1100 Volt working pressure of size 100 mm height, 65mm dia, including one galvanised mild steel spindle, two galvanized iron washer and one GI nut complete all as specified and directed by Engr-in-charge. |
| 61 | Supply and fix in repairs Shackle type Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 100 mm and dia 115 mm having working pressure 1100 volts grade complete all as specified and directed by Engr-in-charge. |
| 62 | Supply & transporting and erecting in replacement octagonal hot dipped galvanised mild steel pole with grey powder finish 7 meter long complete with top dia of size 70 mm and bottom dia of size 130 mm including base plate of size 200X200X12 mm, foundation nuts bolts including RCC foundation of suitable size to withstand the said pole and GI bracket for mounting on top of the pole for fixing of 01 Nos of street light complete all as specified and directed by Engr-in-Charge for street lights. Note :- (a) Cost of Excavation for removing of old RCC pole of required length ,width and depth are deemed to include in this rate. (b) Cost of Excavation for fixing of New octagonal pole of required length ,width and depth are deemed to include in this rate. |
| 63 | Taking down the GI/PVC cable protection pipe along with UG cable from pole/wall by disconnecting all incoming and outgoing connections from the unserviceable street/security light junction boxes and breaking the pole coping, opening the cable loop kept under the pipe/any description by excavation of earth work, cut the damaged portion of UG cable of any size and making new termination arrangement etc,. cut the GI/PVC pipe of required length, fix the same in the existing pole by fixing new GI clamps , provision of new cable junction boxes IP 66 protected “halogen free and weather proof” suitable for out door type ( with metric knockouts for cable entry) including necessary suitable size new aluminium bus bar 04 Nos mounted on saddles suitable for 3 phase 4 wire system of suitable length and thickness, connection of street light connections, re-filling the excavated soils including making good the damaged coping by providing new PCC 1:3:6 & plastering of existing size complete all as specified and directed by Engr-in-charge. |
| 64 | Material and labour for LT Cable Junction Box fabricated from 2.0 mm thick CRCA sheet steel and constructed as a weatherproof, rust-proof and dustproof enclosure conforming to IP65 protection as per IS/IEC 60529. The junction box shall be of standard dimensions suitable for LT cable terminations: for 1–2 runs of 3.5C 25–95 sq.mm cable, size 600 mm (H) × 450 mm (W) × 300 mm (D). These sizes ensure sufficient space for cable bending radius, busbar mounting, and safe clearances as per IS 8623 and IS 732. The box shall be powder-coated (60–80 microns) over red-oxide primer and shall house high-conductivity aluminium bus bars of appropriate rating 200A duly electro-tinned and mounted on DMC/SMC insulators. Cable entry shall be via a removable gland plate with knockouts, equipped with double-compression brass/aluminium cable glands, and cable terminations shall use tinned copper/aluminium lugs. The enclosure shall have a gasket hinged door, locking arrangement, internal and external earthing studs as per IS 3043, and all live parts shall be fully shrouded. The assembly shall be fully tested for insulation resistance, continuity, mechanical strength, and high-voltage withstand at 2.5 kV for one minute before installation. A nameplate and cable identification labels shall be provided as per relevant standards complete all as specified and directed by Engr-in-charge. |
| 65 | Supply and installation of 100 KVAr APFC panel 'KIOSK type' cubical, weather, dust and vermin proof (out door type) CPRI approved factory made suitable for operation on 1100 volts 3 phase, 4 wire, 50 HZ AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3mm thick CRCA steel sheet as size having opening and locking arrangement both from front and back side with cable tray of size not less than 20 cm including copper busbar size 25x06 mm, fixing on angle iron size of 50x50x6mm including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories :-(i) MCCB 160 Amps 4 Pole 25 KA (ii) 8 step intelligent power factor controller - 01 set(ii) Capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 volt & 50 HZ system for permissible non-linear load 15% of 5 KVAR capacity with 10 Amps TP MCB, Duty contactor, Auto/manual switch, illuminated push button/indicators. - 02 set(iii) - do - but 10 KVAR capacity with 16 Amps TP MCB - 04 set(iv) - do - but 15 KVAR capacity with 32 Amps TP MCB - 01 set(v) - do - but 20 KVAR capacity with 32 Amps TP MCB - 01 set(vi) - do - but 25 KVAR capacity with 40 Amps TP MCB - 01 set(vii) Supply and fix multi function digital meter with LCD display including PT and CT having CTR 50/5 (Parameters : V, A, F, PF, kW, kVA, KWh, kVAh, kVARh) - 01 No (viii) Indicators with neon lamp with RYB shade, 240 volts 50 c/s of suitable capacity resistance - 01 set.(ix) Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments - 01 lot. |
| 66 | Supply and installation of The LT Distribution Panel factory-fabricated, cubical, outdoor-type, floor-mounted LT distribution board designed for 415 V, 3-phase, 4-wire, 50 Hz AC distribution systems. The enclosure shall be fabricated from 3.0 mm CRCA sheet steel with a robust welded structure, having IP65 weatherproof protection suitable for coastal, humid, and high-corrosion proof. The panel shall undergo a seven-tank pretreatment process followed by powder coating (minimum 80 microns) in light grey, with anti-corrosive properties suitable for salt-laden atmosphere.The panel shall be of double-door outdoor kiosk type with front and rear access, natural ventilation louvers with insect/vermin-proof mesh, and pad lockable doors. Typical size for a standard GED LT panel shall be 1800 mm (H) × 1600 mm (W) × 800 mm (D) for 400–630 A rating distribution. The panel shall consist of separate compartments for bus bars, incomer breaker, metering, and outgoing feeders to ensure operator safety and ease of maintenance. The busbar chamber shall contain electrolytic aluminium bus bars of rating 600 A duly colour-coded with heat-shrink sleeves (R-Y-B-N), supported on SMC/DMC insulators, and sized for maximum 35–40°C ambient with a temperature rise limit as per IS. Bus bars shall include phase barriers and PVC shrouding to prevent accidental contact.The panel shall have an including with all accessories of incoming MCCB 400 A, with adjustable thermal-magnetic/microprocessor-based protection and breaking capacity of 36kA, depending on the system fault level. Outgoing feeders shall consist of individual MCCBs (63 A × 4 nos),MCCBs (100 A × 3 nos), MCCBs (160 A × 2 nos)MCCBs (250 A × 1 nos),MCCBs (320 A × 1 nos) mounted in separate compartments with cable alleys for proper termination, as required in rural and urban LT distribution networks. Each feeder shall supply LT AB cable / LT XLPE cable outgoing lines for pole distribution systems. Metering shall include a digital multifunction meter showing V, A, PF, kW, kWh, frequency, and demand. Indicating lamps, control wiring (FRLS copper), and auxiliary relays shall be provided as needed. Cable entry shall be bottom-entry through a detachable, gasket gland plate fitted with high-quality double-compression brass or aluminium glands. The panel shall include a full-length GI/Aluminium earth busbar, dual earthing studs, and earth bonds for all doors.The LT Distribution Panel shall comply with relevant safety regulations followed by Electricity Department. The complete assembly shall be routine-tested for insulation resistance, high-voltage withstand, mechanical strength, continuity, and operational performance prior to dispatch. A stainless-steel nameplate indicating panel rating complete all as specified and directed by Engr-in-charge. |
| 67 | Supply and installation of The LT Distribution Panel factory-fabricated, cubical, outdoor-type, floor-mounted LT distribution board designed for 415 V, 3-phase, 4-wire, 50 Hz AC distribution systems. The enclosure shall be fabricated from 3.0 mm CRCA sheet steel with a robust welded structure, having IP65 weatherproof protection suitable for coastal, humid, and high-corrosion proof. The panel shall undergo a seven-tank pretreatment process followed by powder coating (minimum 80 microns) in light grey, with anti-corrosive properties suitable for salt-laden atmosphere.The panel shall be of double-door outdoor kiosk type with front and rear access, natural ventilation louvers with insect/vermin-proof mesh, and pad lockable doors. Typical size for a standard GED LT panel shall be 1800 mm (H) × 1600 mm (W) × 800 mm (D) for 400–630 A rating distribution. The panel shall consist of separate compartments for bus bars, incomer breaker, metering, and outgoing feeders to ensure operator safety and ease of maintenance. The busbar chamber shall contain electrolytic aluminium bus bars of rating 500 A duly colour-coded with heat-shrink sleeves (R-Y-B-N), supported on SMC/DMC insulators, and sized for maximum 35–40°C ambient with a temperature rise limit as per IS. Bus bars shall include phase barriers and PVC shrouding to prevent accidental contact.The panel shall have an including with all accessories of incoming MCCB 320 A, with adjustable thermal-magnetic/microprocessor-based protection and breaking capacity of 36kA, depending on the system fault level. Outgoing feeders shall consist of individual MCCBs (63 A × 3 nos),MCCBs (100 A × 2 nos), MCCBs (160 A × 1 nos)MCCBs (250 A × 1 nos) mounted in separate compartments with cable alleys for proper termination, as required in rural and urban LT distribution networks. Each feeder shall supply LT AB cable / LT XLPE cable outgoing lines for pole distribution systems. Metering shall include a digital multifunction meter showing V, A, PF, kW, kWh, frequency, and demand. Indicating lamps, control wiring (FRLS copper), and auxiliary relays shall be provided as needed. Cable entry shall be bottom-entry through a detachable, gasket gland plate fitted with high-quality double-compression brass or aluminium glands. The panel shall include a full-length GI/Aluminium earth busbar, dual earthing studs, and earth bonds for all doors.The LT Distribution Panel shall comply with relevant safety regulations followed by Electricity Department. The complete assembly shall be routine-tested for insulation resistance, high-voltage withstand, mechanical strength, continuity, and operational performance prior to dispatch. A stainless-steel nameplate indicating panel rating complete all as specified and directed by Engr-in-charge. |
| 68 | Supply and installation of The LT Distribution Panel factory-fabricated, cubical, outdoor-type, floor-mounted LT distribution board designed for 415 V, 3-phase, 4-wire, 50 Hz AC distribution systems. The enclosure shall be fabricated from 3.0 mm CRCA sheet steel with a robust welded structure, having IP65 weatherproof protection suitable for coastal, humid, and high-corrosion proof. The panel shall undergo a seven-tank pretreatment process followed by powder coating (minimum 80 microns) in light grey, with anti-corrosive properties suitable for salt-laden atmosphere.The panel shall be of double-door outdoor kiosk type with front and rear access, natural ventilation louvers with insect/vermin-proof mesh, and pad lockable doors. Typical size for a standard GED LT panel shall be 1800 mm (H) × 1600 mm (W) × 800 mm (D) for 400–630 A rating distribution. The panel shall consist of separate compartments for bus bars, incomer breaker, metering, and outgoing feeders to ensure operator safety and ease of maintenance. The busbar chamber shall contain electrolytic aluminium bus bars of rating 400 A duly colour-coded with heat-shrink sleeves (R-Y-B-N), supported on SMC/DMC insulators, and sized for maximum 35–40°C ambient with a temperature rise limit as per IS. Bus bars shall include phase barriers and PVC shrouding to prevent accidental contact.The panel shall have an including with all accessories of incoming of MCCB 250 A, with adjustable thermal-magnetic/microprocessor-based protection and breaking capacity of 36kA, depending on the system fault level. Outgoing feeders shall consist of individual MCCBs (63 A × 2 nos),MCCBs (100 A × 2 nos), MCCBs (160 A × 1 no) mounted in separate compartments with cable alleys for proper termination, as required in rural and urban LT distribution networks. Each feeder shall supply LT AB cable / LT XLPE cable outgoing lines for pole distribution systems. Metering shall include a digital multifunction meter showing V, A, PF, kW, kWh, frequency, and demand. Indicating lamps, control wiring (FRLS copper), and auxiliary relays shall be provided as needed. Cable entry shall be bottom-entry through a detachable, gasket gland plate fitted with high-quality double-compression brass or aluminium glands. The panel shall include a full-length GI/Aluminium earth busbar, dual earthing studs, and earth bonds for all doors.The LT Distribution Panel shall comply with relevant safety regulations followed by Electricity Department. The complete assembly shall be routine-tested for insulation resistance, high-voltage withstand, mechanical strength, continuity, and operational performance prior to dispatch. A stainless-steel nameplate indicating panel rating complete all as specified and directed by Engr-in-charge. |
| 69 | Material and labour as in repairs for stay assembly complete with all sections such as stay plate, stay clamps, Stay brackets with 20 mm dia stay rod complete all as shown in electrical plate No. 1 of SSR Part 1 complete. (Note : Loop insulator, excavation and concrete work will be measured and paid separately) |
| 70 | Material and labour as in repairs for stay strand size 7/3.15 mm all as specified and fixed to stay and pole including lightening complete all as specified and directed by Engr-in-charge. |
| 71 | Material and labour as in repairs loop type insulator vitreous porcelain white, brown or green of size 65x90 mm overall dimension and 16 mm clearance of hole complete all as specified and directed by Engr-in-charge. |
| 72 | Supply and Fix Street light timer panel with Astronomical switch range of 6 kw to 12 kw & contactor rating 32 A TP to 65 A TP and MCB rating 40A TPN to 63 A TPN with programmable time switch for SLP, Confirming to IS /IEC 61439 & 60529, Provided with protection degree IP54, Extended wide band coil, FRLS (Fire retardant low smoke) internal wiring, In-built short-circuit protection, class H insulation complete all as specified and directed. |
| 73 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated 2 core stranded aluminium conductor served with an inner sheathing of PVC tape PVC sheathed 4 sqmm nominal cross section in service connection/light connections in poles from junction box to fittings complete all as specified and directed by Engr-in-charge. |
| 74 | Material and labour for removing vegetation, grass, scrubs and bushes or any small tree branches growing in Sub station yard along with fencing, around the pole, under the HT/LT transmission lines, yards or any description by manually/mechanically and keep the sub station yard neat and clean complete all as specified and directed by Engr-in-charge. (Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid.) |
| 75 | Material and labour for Cutting and trimming of tree branches of girth up to 150 mm dia and 3 mtr all around of any size obstructing lumination of street light/perimeter lights and touching LT/HT Over head line including removing trimmed tree branches complete all as specified and directed by Engr-in-charge.Note ; Each cut will be measured and paid |
| 76 | Supply & laying the ready to use materials for repairing pot holes in flexible roads (bitumen roads) modified all weather bitumen paste in liquid asphalt with chemicals antistripping agents, graded aggregates and additives can be used in temp in the range of 0 to 50 degree Celsius complete all as specified and as directed. |
| 77 | Material and labour for Replacement of ACSR type jumpers(appx 1.5 RM in length) of suitable dia including aluminium lugs of suitable size for HT structures and yards including PVC insulation pipe and cleaning of carbon deposited on joints, applying jelly to each contact points and GOD male & female contacts and dismantling old jumpers complete all as specified and as directed. |
| 78 | Supply only of PVC electrical LT insulation tape 18 mm width in 6 mtr roll all as specified and directed. |
| 79 | Supply and fix of alluminium cable lugs/ferrol of size 10 to 35 sqmm complete all as specified and directed by Engr-in-charge |
| 80 | All as per item No.78 here in before but of capacity 50 to 95 sqmm complete all as specified and directed by Engr-in-charge. |
| 81 | All as per item No.78 here in before but of capacity 120 to 240 sqmm complete all as specified and directed by Engr-in-charge. |
| 82 | Supply and fix of cable gland of following size 10 to 70 sqmm dia complete all as specified and directed by Engr-in-charge |
| 83 | Supply and fix of cable gland of following size 95 to 240 sqmm dia complete all as specified and directed by Engr-in-charge |
| 84 | Supply and fix in repair Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15 cm size all as directed. |
| 85 | Material and labour painting of HT / LT Panel of any size by preparation of old surface and applying one coat of red oxide primer and two coat of synthetic enameled paint of standard colour code as existing surface all as specified and directed by Engr-in-charge.(Note:- Colour of paint decided by Engr-in-charge.) |
| 86 | Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage up to 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m |
| 87 | Material and labour for PCC 1:3:6 type C1 using 20 mm graded trap stone aggregate for repair of earth pit, Pole coping, Cable duct PCC near GOD and transformer etc as directed by Engineer-in-Charge. |
| 88 | Material and labour for graded coarse aggregate (broken stone or boulders) of size 40 mm in substation yard for laying complete all as specified and directed by Engr-in-charge. |
| 89 | Material and labour for 2.5 Sqmm 2 core FR, PVC insulated copper conductor cable unsheathed 1100 volts grade multi stranded including earth wire from street light fitting to looping box on pole through the GI tubing bracket complete all as specified and directed. |
| 90 | Supply & Fixing PVC unarmoured 1100V grade three core multistranded copper conductor cable of size 2.5 Sqmm including lugs on both ends and including connection complete all as specified and directed. |
| 91 | Supply & Fixing PVC unarmoured 1100V grade three core cable, stranded aluminium conductor of size 4 Sqmm complete all as specified and directed. Please Enable Macros to View BoQ information |
| 92 | Supply & Fixing PVC unarmoured 1100V grade three core cable, stranded aluminium conductor of size 4 Sqmm complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail