Tender For General- Proposed Office Shifting And Seating Arrangement For Ce ,Re And Ho Accounts Section Civil And Electrical Works- Proposed Office Shifting And Seating Arrangement For Ce &Re Of Ho Accounts Section-General Civil Work
Tender Overview
Project Description
Tender for General- Proposed Office Shifting And Seating Arrangement For Ce ,Re And Ho Accounts Section Civil And Electrical Works- Proposed Office Shifting And Seating Arrangement For Ce &Re Of Ho Accounts Section-General Civil Work
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Jun-2026 | Corrigendum | Other | 30-Jun-2026 |
| 2 | 01-Jul-2026 | Date Extension Corrigendum | Date | 06-Jul-2026 |
| 3 | 27-Jun-2026 | Corrigendum | Other | 06-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | PROPOSED OFFICE SHIFTING AND SEATING ARRANGEMENT FOR CE &RE OF HO ACCOUNTS SECTION |
| 2 | 21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 3 | 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 4 | 6.38:Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry100 mm/ 125 mm thick with Grade- I AAC blocks of density 551 to 650 Kg/ cumconforming to IS: 2185 (Parts-3) in super structure above plinth level up to floor Vlevel in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providingand placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonrywork. |
| 5 | 6.47:Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry150mm/230mm/300 mm thick with Grade- I AAC blocks in super structureabove plinth level up to floor V level with RCC band at sill level and lintellevel with approved block laying polymer modified adhesive mortar allcomplete as per direction of Engineer-in-Charge. (The payment of RCC bandand reinforcement shall be made for seperately). |
| 6 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 7 | OD19170/2026-2027:Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top and bottom pivots, double acting hydraulic floor spring type fixing arrangement, making necessary holes/cut-outs for fixing required door fittings, including top and bottom patch fitting set, stainless steel pull handle pair, lock with keys, silicone sealant, gasket, screws and all other incidental accessories, complete as per the direction of Engineer-in-Charge. Door stopper shall be paid for separately. |
| 8 | 14.34:Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete |
| 9 | 21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 10 | 9.79.2:Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.50 mm |
| 11 | 9.79.4:Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.75 mm |
| 12 | 9.80:Providing and fixing 50 mm bright finished brass cup board or wardrobe knob of approved quality with necessary screws. |
| 13 | 9.83:Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 14 | 9.88:Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 15 | 21.2.2:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides |
| 16 | OD19375/2026-2027:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge.:With frosted glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) |
| 17 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 18 | 13.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 19 | 13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 20 | 13.88:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 21 | 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 22 | 9.169:Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes, shelves, racks, almirah, cupboard and drawer etc. including necessary nails, screws etc. complete as per direction of Engineer-in-charge. |
| 23 | 9.171:Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. |
| 24 | 9.170.1:Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge.200 mm |
| 25 | 9.115:providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer -in-charge. |
| 26 | OD420379/2025-2026:Shifting existing office materials including furniture, files, chairs, tables, equipment, and other office items from LZ 1st Floor to Head Office 2nd Floor, including: Careful packing, dismantling (if required), and loading of materialsTransportation within building via stairs Unloading, re-arranging, and placing at designated locationsHandling fragile items with careIncluding labour, helpers, trolleys, ropes, and all incidental chargesComplete as directed by Engineer-in-charge |
| 27 | 12.53:Providing and Fixing 15 mm thick densified tegular edged eco friendly lightweight calcium silicate false ceiling tiles of approved texture of size 595 x 595mm in true horizontal level, suspended on inter locking metal grid of hot dippedgalvanised steel sections (galvanising @ 120 grams per sqm including bothside) consisting of main ‘T’ runner suitably spaced at joints to get requiredlength and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm(Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre tocentre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mmand size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked atmiddle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting onperiphery walls /partitions on a Perimeter wall angle pre-coated steel ofsize(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help ofrawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230mm interval and laying 15 mm thick densified edges calicum silicate ceilingtiles of approved texture in the grid, including, cutting/ making opening forservices like diffusers, grills, light fittings, fixtures, smoke detectors etc.,wherever required. Main ‘T’ runners to be suspended from ceiling using G.I.slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mmlong dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clipsof size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’,bottom exposed with 24 mm of all Tsections shall be pre-painted with polysterbaked paint, for all heights, as per specifications, drawings and as directed byEngineer-in-Charge. |
| 28 | OD20584/2026-2027:Cleaning existing mosaic flooring using approved diluted acid solution, scrubbing with rotary machine/manual brush, removing stains, washing with clean water, neutralising surface and disposing debris complete, including dismantling and repairing damaged / hollow / broken portions of existing mosaic flooring near wall junctions or wherever required, using cement mortar/terrazzo mix to match existing flooring, curing, rubbing and finishing the repaired portions to proper level and alignment, complete as directed by Engineer-in-charge. |
| 29 | toilet |
| 30 | 15.12.1:Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below |
| 31 | 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 32 | 15.23.1:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 33 | 15.52:Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead |
| 34 | 14.82:Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge |
| 35 | OD22425/2026-2027:Providing, supplying and installing toilet cubicle partitions made of 12 mm thick suede finish HPL compact laminate sheet of approved make and shade, for toilet cubicles of sizes as per architectural drawing such as 107 cm × 120 cm or 114 cm × 120 cm, including door shutter of size 60 cm × 178.5 cm, all edges machine finished and polished. The cubicle partition shall have divider panel height 182 cm and overall height 195 cm including 15 cm clear gap from finished floor level, complete with all required SS 316 grade hardware fittings such as gravity hinges, adjustable legs, coat hook, door knob/indicator lock, screws etc. including anodised aluminium U-channel, top rail, door stopper channel, brackets and all accessories required for proper fixing. The work shall include cutting, drilling, aligning, assembling, erection in position, making good damages, cleaning and handing over complete, all as per approved drawing and direction of Engineer-in-Charge. |
| 36 | 13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) |
| 37 | 4.2.2:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources |
| 38 | OD19477/2026-2027:Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm or 600 x 1200 |
| 39 | OD19478/2026-2027:Providing and laying Matt/Antiskid finish Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tiles 600x600 mm |
| 40 | OD19479/2026-2027:Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in walls, skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 1200 x 600 mm |
| 41 | 26.89.1: Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-InCharge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) 18 mm thick |
| 42 | 26.86.2:Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/ mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 45 x 85 mm |
| 43 | 22.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 44 | OD21675/2026-2027:Providing and laying Grade-I AAC block masonry of required thickness for sunken portion filling / raising in toilet areas, including proper laying, ,cutting to required size, finishing top level ready for waterproofing / screed, complete as directed by Engineer-in-Charge. |
| 45 | 17.60.2.3:Providing and fixing trap of self cleansing design with screwed down or hinged grating without vent arm complete, including cost of cutting and making good the walls and floors:100 mm inlet and 75 mm outletHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 46 | 17.81:Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 47 | 17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid |
| 48 | 18.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 49 | 17.7.11:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Stainless Steel AISI - 304 (18/8) Wash basin 530 x 345 mm with single 15mm C.P. brass pillar tap |
| 50 | 17.23:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 51 | 17.32.4:Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm |
| 52 | 17.69.2:Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 38 mm dia of 83 mm length and 77 mm breadth, weighing not less than 60 gms |
| 53 | 17.28.2.1:Flexible pipe32 mm dia |
| 54 | 18.21.1.1:Providing and fixing uplasticised PVC connection pipe with brass unions:30 cm length15 mm nominal bore |
| 55 | 50.17.1.5:Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 56 | 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 57 | 50.18.8.7.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2 |
| 58 | 50.18.78:Making chases up to 12.5x12.5 cm in walls including making good and finishing with matching surface after housing pipe etc. |
| 59 | 50.18.9.20.5:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee |
| 60 | 50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 61 | 50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 62 | 50.18.9.20.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow |
| 63 | 50.18.9.20.9:Providing and fixing PVC moulded fitting / accessories for Rigid PVC pipes, including jointing with PVC solvent cement-63 mm dia Socket /coupling |
| 64 | 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow |
| 65 | 18.51.1:Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 66 | 50.18.9.22.11:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling |
| 67 | ELECTRICAL |
| 68 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 69 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 70 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 71 | 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 72 | 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 73 | 1.14.7:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 74 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 75 | 1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm |
| 76 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 77 | 1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm |
| 78 | 1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm |
| 79 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 80 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm |
| 81 | 1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm |
| 82 | 1.18.2:Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 83 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 84 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 85 | 1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 86 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 87 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 88 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 89 | 1.55.1:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A |
| 90 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 91 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 92 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 93 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 94 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 95 | 1.24.6:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 96 | 1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push |
| 97 | 1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 98 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 99 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 100 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 101 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 102 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 103 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 104 | 2.2.13:Providing and fixing following rating and breaking capacity MCCB withthermomagnetic release and terminal spreaders in existing cubicle panel boardincluding drilling holes in cubicle panel. making connections. etc. as required.100 Amp, 30 KA 4 Pole |
| 105 | 90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) |
| 106 | 90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 107 | 19.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: |
| 108 | 90.9.1.8:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flanged coupler |
| 109 | 90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid |
| 110 | 90.9.2.10:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Joint cover |
| 111 | 90.9.2.11:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer |
| 112 | 90.9.2.2:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider |
| 113 | 90.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree |
| 114 | 90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap |
| 115 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 116 | 90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator |
| 117 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 118 | 90.9.2.12:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box |
| 119 | 90.9.2.13:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.4 to 5 module mounting box |
| 120 | 90.9.2.19:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Reducer 100 x 50 to 50 x 50mm |
| 121 | 90.9.2.21:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Special external angle 45 degree |
| 122 | 90.9.2.23:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External tee |
| 123 | 1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 124 | 1.53.2:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable |
| 125 | 1.53.3:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required3 run of Cable |
| 126 | OD29877/2026-2027:Supply, conveyance, installation, testing & commissioning of 12W Tiltable COB LED Light (Recessed Type) suitable for installation in gypsum false ceiling. The luminaire shall be COB (Chip-on-Board) LED type, providing high efficiency, focused and glare-free illumination. The fixture shall be provided with tiltable (adjustable beam angle) mechanism for directional lighting. The body shall be made of aluminium for effective heat dissipation with suitable reflector and diffuser arrangement. The driver shall be integrated constant current type suitable for operation on 220–240V AC, 50Hz supply, with surge protection and high power factor. The item shall include spring clip mounting suitable for gypsum ceiling, connectors, and electrical wiring using 3-core flexible copper cable, complete as directed by Engineer-in-Charge. |
| 127 | OD29878/2026-2027:Supply, conveyance, installation, testing & commissioning of wall mounted oscillating fan of standard reputed make, suitable for indoor air circulation. The fan shall be complete with energy efficient motor, oscillation mechanism, 3-speed control, and safety grill. The item shall be suitable for operation on 230V AC, 50Hz supply and shall include necessary wall mounting bracket, fasteners, wiring connection, and commissioning as required and directed by Engineer-in-Charge. |
| 128 | OD29879/2026-2027:Supply, conveyance, installation, testing & commissioning of 20W COB LED Light (Ceiling Recessed Type) suitable for installation in gypsum false ceiling. The luminaire shall be high-efficiency COB (Chip-on-Board) LED type, providing high brightness and focused, glare-free illumination. The fixture shall be suitable for operation on 220–240V AC supply, with integrated constant current LED driver having high power factor and surge protection. The body shall be made of aluminium for effective heat dissipation with suitable reflector and diffuser arrangement. The fitting shall be complete with necessary spring clip mounting suitable for gypsum ceiling installation, connectors, and electrical wiring using 3-core flexible copper cable, as required and directed by Engineer-in-Charge. |
| 129 | OD29880/2026-2027:Supply, conveyance, installation, testing & commissioning of 100W LED Profile Light (Linear / Slim Panel Type) suitable for installation in false ceiling / gypsum ceiling as required. The luminaire shall be made of extruded aluminium housing with high-quality opal diffuser to ensure uniform light distribution without glare. The fixture shall provide continuous linear illumination using high-efficiency LED technology suitable for modern architectural lighting applications. The LED driver shall be constant current type with high power factor and surge protection, suitable for operation on 220–240V AC supply. The fitting shall be complete with necessary suspension accessories, mounting clips, connectors, and electrical wiring including 3-core flexible copper cable, complete as required and as directed by Engineer-in-Charge |
| 130 | OD29881/2026-2027:Supply, conveyance, installation, testing & commissioning of 2 feet LED Mirror Tube Light (LED batten type) complete with all accessories. The fitting shall be suitable for wall/ceiling mounting and shall provide uniform glare-free illumination suitable for mirror lighting applications. The luminaire shall be energy efficient LED type with integrated driver, high lumen output, and long life operation. The item shall include all necessary fixing accessories, connectors, and electrical connections as required and as directed by Engineer-in-Charge. |
| 131 | OD29882/2026-2027:Supply, conveyance, installation, testing & commissioning of recess-mounted LED downlighter (circular / square type) with wattage range 15–18W, complete with all necessary accessories. The luminaire shall be suitable for installation in gypsum / POP false ceiling, with proper spring clip mounting arrangement. The fitting shall provide uniform glare-free illumination and shall be complete in all respects including driver, housing, diffuser, and connection accessories as required and as directed by Engineer-in-Charge |
| 132 | OD29883/2026-2027:Supply, conveyance, installation, testing & commissioning of 1200 mm 1x20W LED Tube Light Fixture (Box Type) complete with all accessories. The fitting shall be made of white powder-coated / pre-coated CRCA steel channel housing, suitable for single LED T8 tube. The luminaire shall have aluminium housing with polycarbonate diffuser, providing uniform light distribution. The LED tube shall be 6500K cool white, output approximately 2000 lumens, with IP20 protection, CRI ≥80, THD <20%, surge protection 2kV, and rated life of ≥50,000 burning hours. The driver shall be multistage isolated constant current type, operating in the range 110–265V AC, with SELV (Safe Extra Low Voltage <60V DC) as per IEC standards. The fitting shall be single-sided connection type and include all necessary accessories. Installation shall include wall mounting and electrical connection using 16/0.20 mm 3-core PVC insulated and sheathed round copper conductor flexible wire, or extension of existing wiring as required, complete as directed by Engineer-in-Charge. |
| 133 | OD29884/2026-2027:Supply, providing, installation (if required), testing and commissioning of 7W to 9W LED Bulb of PWD approved make, suitable for general lighting applications. The LED bulb shall be energy efficient, long life type with high lumen output, suitable for operation on 230V AC, 50Hz supply. The item shall be complete in all respects including testing and commissioning as per direction of Engineer-in-Charge. |
| 134 | OD29885/2026-2027:Supply, conveyance, installation, testing & commissioning of Slim Panel Surface Mounted LED Down lighter15-18W complete with all accessories. The luminaire housing shall be made of die-cast aluminium for efficient heat dissipation. It shall be provided with high transmissivity diffuser for uniform light distribution without glare. The driver and accessories shall be pre-wired for easy installation and long service life. The fitting shall comply with the following specifications: CRI > 70, colour temperature ≥ 6000K (cool white), IP20 protection, ambient temperature range 0°C to 45°C, driver efficiency >85%, THD <20%, power factor >0.95, surge protection 2KV, and multistage isolated constant current driver operating in the range 150–270V AC with SELV (Safe Extra Low Voltage <60V DC) as per IEC standards. Wattage shall be 15–18W, with luminaire lumen output ≥ 2000 lumens. The fitting shall be supplied with 3-core round flexible cable wiring connection, complete as required and installed as directed by Engineer-in-Charge. |
| 135 | OD29886/2026-2027:Supply, installation, testing & commissioning of 1 TR Split Type Air Conditioner, 5 Star rated, of reputed make, suitable for efficient cooling and energy saving. The unit shall include indoor and outdoor units complete with remote control and standard installation kit. The work shall also include supply and fixing of suitable voltage stabilizer compatible with the AC unit, and heavy-duty outdoor unit stand for proper mounting. The installation shall include refrigerant copper piping (up to 3 meters standard length) with insulation, drain piping, electrical interconnection wiring between indoor and outdoor units, vacuuming, gas charging (if required), testing, and commissioning at site in a convenient position as directed by Engineer-in-Charge. |
| 136 | OD29887/2026-2027:Supply, installation, testing & commissioning of 1.5 TR Split Type Air Conditioner, 5 Star rated, of reputed make, suitable for efficient cooling and energy saving. The unit shall include indoor and outdoor units, complete with remote control and standard installation kit. The work shall also include supply and fixing of suitable voltage stabilizer compatible with the AC unit, and heavy-duty outdoor unit stand for proper mounting. The installation shall include refrigerant copper piping (up to 3 meters standard length) with insulation, drain piping, electrical wiring connection between indoor and outdoor units, vacuuming, gas charging (if required), testing, and commissioning at site in a convenient position as directed by Engineer-in-Charge. |
| 137 | OD29888/2026-2027:Supply, installation, testing & commissioning of 6U, 19-inch wall-mounted rack cabinet with front toughened glass door and rear perforated metal door with handle lock & key. The rack shall be provided with front and rear adjustable 19” mounting angles, top and bottom cable entry openings, and powder coated finish in RAL 9005 (black) / RAL 7035 (grey) textured finish. The cabinet shall be complete with all necessary accessories including mounting hardware, cage nuts, screws, and earthing provision, and shall be installed as per manufacturer specifications and as directed by Engineer-in-Charge. |
| 138 | OD29889/2026-2027:Supply, installation, testing & commissioning of IP-based Varifocal Bullet CCTV Camera (PoE enabled) with 2 Megapixel resolution, suitable for indoor/outdoor surveillance. The camera shall support varifocal lens (2.8/3.6 mm to 9/12 mm), H.264 / H.265 video compression, and built-in IR LED illumination with 20–30 meter IR range. It shall be equipped with 1/2.8” progressive scan CMOS sensor, Day/Night (ICR) functionality, and IP66 weatherproof protection for outdoor use. The camera shall support Power over Ethernet (PoE IEEE 802.3af/at) for single-cable power and data transmission. The item shall include all necessary mounting accessories suitable for wall mounting / false ceiling / true ceiling as required, connectors, testing, configuration, and commissioning as directed by Engineer-in-Charge. |
| 139 | OD29890/2026-2027:Supply, installation, testing & commissioning of IP-based Dome CCTV Camera (PoE enabled) with 2MP resolution, varifocal lens (2.8/3.6 mm to 9/12 mm), suitable for indoor surveillance. The camera shall be equipped with 1/2.8” progressive scan CMOS sensor, supporting H.264 / H.265 compression, Day/Night (IR cut filter), and integrated IR LEDs with 20–30 meter IR range. The camera shall support 120 dB Digital WDR for improved image clarity in high contrast lighting conditions. It shall be ONVIF compliant and compatible with standard NVR systems. The item shall include PoE (Power over Ethernet) support, all required mounting accessories suitable for false ceiling installation, connectors, testing, configuration, and commissioning as per direction of Engineer-in-Charge. |
| 140 | OD29891/2026-2027:Supply, installation, testing & commissioning of 12 Channel Network Video Recorder (NVR) with 30 days continuous recording storage capacity, including required surveillance-grade HDDs. The NVR shall support 12 IP camera channels, recording at 720P resolution at real-time (20 FPS or higher) and support maximum recording resolution up to 4 MP per channel. It shall be ONVIF compliant for compatibility with multiple IP camera brands. The system shall support H.265 / H.264 compression formats, dual HDMI video output, and remote viewing capability. The NVR shall include necessary networking features, power supply, rack mounting accessories (if applicable), and all accessories required for complete installation, testing, configuration, and commissioning as directed by Engineer-in-Charge. Storage capacity shall be designed and provided to ensure 30 days continuous recording for all 12 channels at 720P, 20 FPS, and detailed storage calculation shall be submitted for approval. |
| 141 | OD29892/2026-2027:Supply and crimping of RJ45 Cable Connector (8P8C) of standard make such as D-Link or equivalent, suitable for CAT5E/CAT6 UTP LAN cables. The work shall include supply of RJ45 modular plug, proper termination/crimping of twisted pair cable using professional crimping tool, ensuring correct pin configuration (T568A/T568B as required), testing for continuity and connectivity, and making the connection fully functional as per structured cabling standards and direction of Engineer-in-Charge |
| 142 | OD29893/2026-2027:Supply, installation, testing & commissioning of sheet steel, phosphatised and powder coated FP enclosure, dust and vermin proof type, suitable for independent mounting of MCB / RCCB / RCBO. The enclosure shall be fabricated from CRCA sheet steel, with corrosion-resistant phosphatised treatment and painted finish. It shall be provided with hinged door, locking arrangement, cable entry knockouts, DIN rail mounting arrangement, and all necessary internal wiring accessories as required. The enclosure shall be complete in all respects as per site requirement and as directed by Engineer-in-Charge |
| 143 | OD29894/2026-2027:upply and fixing of CAT5E Patch Cord (2 meter length) of standard make such as D-Link / iBall or equivalent, Model: iB-PPC5E2M or approved equivalent. The patch cord shall be Unshielded Twisted Pair (UTP), 4 pairs, 24 AWG stranded copper cable, CAT5E compliant. It shall be snag-less type designed with strain-relief boot for durability and easy installation. The RJ45 connectors shall have polycarbonate housing with 50-micron gold over nickel plated contacts. The patch cord shall comply with or exceed EIA/TIA 568C standards, color: grey, including supply, installation, testing, and connection as directed by Engineer-in-Charge. |
| 144 | OD29895/2026-2027:Supply and installation of CAT6 Information I/O Outlet (Data Point) consisting of CAT6 RJ45 keystone jack, fixed in modular face plate, mounted on CMS (Concealed Modular Switch/Box) including suitable GI/metal or PVC mounting box, steel screws, and all required fixing accessories. The work shall include termination of CAT6 cable on keystone jack, proper labeling, testing of data point, and complete installation as per structured cabling standards and direction of Engineer-in-Charge. |
| 145 | OD29896/2026-2027:Supply, installation, testing & commissioning of 24-Port Fully Loaded 19” Rack Mount Patch Panel with RJ45 Keystone Jacks (CAT6/CAT6A as specified). The patch panel shall be fully pre-loaded, rear cable management support, color-coded labeling system, and IDC termination points. It shall be suitable for structured LAN cabling systems and confirm to ANSI/TIA/EIA standards. The item shall include all necessary accessories such as cable ties, labeling tags, mounting screws, and rack fixing hardware as required for complete installation as directed by Engineer-in-Charge. |
| 146 | OD29897/2026-2027:Supply, installation, testing & commissioning of 24-Port Ethernet Switch (10/100/1000 Mbps Gigabit), rack-mountable (19” standard), unmanaged/managed as specified, with all 24 RJ45 auto-sensing ports supporting IEEE 802.3/802.3u/802.3ab standards. The switch shall support plug-and-play operation, full/half duplex auto-negotiation, LED indicators for link/activity, and shall be suitable for LAN / CCTV / networking applications. Complete with power cable, rack mounting kit and accessories required for installation as directed by Engineer-in-Charge. |
| 147 | OD29898/2026-2027:Supply, installation, testing & commissioning of 9U, 19” wall-mounted rack cabinet with front toughened glass door and rear perforated metal door with handle lock & key. Rack shall have front & rear adjustable mounting angles, top and bottom cable entry openings, powder coated finish in RAL 9005 / RAL 7035 texture finish, complete as per specification and directed by Engineer-in-Charge |
| 148 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 149 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 150 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 151 | 90.12.6.40:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm |
| 152 | 90.12.6.42:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 25 sq mm |
| 153 | 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 154 | 90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 155 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 156 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 157 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 158 | 9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 159 | OD31990/2026-2027:Supply, installation, testing and commissioning of 200 mm sweep exhaust fan, heavy duty, complete with motor, blades, frame, mounting arrangements, including making necessary opening in wall/window, fixing with suitable fasteners, cement mortar finishing, supply and wiring with 1.5 sq.mm PVC insulated copper conductor in PVC conduit/casing and capping, including 6A switch, socket, and earthing connection, as required |
| 160 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 days