| 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 2 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In lime mortar |
| 3 | Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sidesand ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed with a lead in a 50 meter including stacking of useful material if available :Ordinary rock |
| 4 | Carriage of following material including loading unloading and stacking if required complete in all respect.Earth, Sand, Lime, Moorum, manure or sludge, Building Rubbish, Stone Metal (Girt and ballast etc), Stone for Masonry work & Soling and Excavated rock etc. for 5 km. |
| 5 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 6 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 7 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix . Add extra for providing richer mixes respectively at all floor level Providing grade concrete by using cement as per codal provision instead of M-20 grade design mix. |
| 8 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. |
| 9 | Providing and fabricating reinforcement for RCC work including straightening, cutting, bending, placing in position in binding (including cost of binding wire ) all complete up to floor three level Thermo mechanically treated bars (conforming to relevant IS code.) |
| 10 | Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 11 | Add extra for Random Rubble stone masonry with hard stone in Square or Rectangular pillars |
| 12 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 .) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia |
| 13 | Brick work with F.P.S. bricks of class designation 75 insuperstructure above plinth level upto floor V level in allshapes and sizes in :Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 14 | Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75 |
| 15 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 16 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks,sills, chhajjas, lintel, beam, plinth beam etc. |
| 17 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 25 mm thick. |
| 18 | Repair to stone masonary in cement sand mortar 1:6 with old and new stone. |
| 19 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) |
| 20 | Plaster on new surface on walls in cement sand mortar 1:4including racking of joints etc. complete fine finish :20mm thick |
| 21 | 120cm. high fencing with angle iron posts 50x50x6mm. placed at every 3 Mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner & every tenth posts to be strutted with 50x50x6mm angle iron provided with four horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staple including earth work in excavation etc. complete. |
| 22 | Add or deduct for each wire line over basic item |
| 23 | Add Extra if barbed wire fencing is done on wall upto heightof 3.00 Mtr. |
| 24 | Providing and fixing steel gate, grating , and grills made ofangles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 25 | Structural steel work riveted, bolted or welded in built upsections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 26 | Add Extra if I/rail section is used |
| 27 | Colour washing of all shades to give an even shade including all scaffolding New work (two or more coats) with a base coat of white washing with lime. |
| 28 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 29 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.1: 3: 6 or richer mix |
| 30 | Providing and fixing welded mesh/expanded metal mesh inframe work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size Welded mesh 25 mmx 25 mm x 2.1 mm |
| 31 | Providing and fixing steel gate, grating , and grills made ofangles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 32 | Providing and fixing steel glazed doors windows andventilator shutters of standard rolled steel section (IS 10381983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawlplugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Partly fixed and partly openable [ fixed area not to exceed 33% |
| 33 | Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 34 | Add extra for double leaf shutters. |
| 35 | Supplying and fixing stone lintels/bed plates of approved quarry rough dressed in cement mortar 1:4 :Upto 15 cm. thick. |
| 36 | Kota stone slab flooring 25 mm thick over 20 mm (average thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab includingrubbing and polishing complete with base of cement mortar 1: 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm |
| 37 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges Kota stone minimum 30mm thick. |
| 38 | Stone slab roofing on ground floor with fine grained stoneslab from approved quarry including filling of joints ofparapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge |
| 39 | Providing and laying brick kharanja on roofs with cementmortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound in square pattern 75mm to 100mm thick average |
| 40 | Providing & laying broken glazed titles on roof ( brokenglazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30Kg/Sqm. Of VG-10 (80/100) grade) and joints filled withcement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineerin-charge. |
| 41 | 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 42 | Painting exterior surface of Wall with 100% acrylic exteriorpaint of approved brand and manufacture to give an evenshade with two or more coats including prepartion of basewith sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision New Work |
| 43 | Wall painting with plastic emulsion paint of approved brandand manufacture to give an even shade including allscaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 44 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, round tiles,Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch,Modular plate with grid plate, screws, making connections, testing etc. as required. Short point (up to 3 mtr.) |
| 45 | Medium point (up to 6 mtr.) |
| 46 | Long point (up to 10 mtr..) |
| 47 | Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it's accessories, Hot Dipped Galvanized M.S Modular box of 20 SWG with earth terminal, 6 A modular switch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required. On board |
| 48 | Short point (up to 3 mtr.) |
| 49 | Supplying and fixing of power plug point Modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost of modular 16 amp. Switch and socket outlet , making connection , testing , etc. as required. |
| 50 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.Gr.-1 1 x 1.5 sq.mm |
| 51 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 52 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 53 | P&F 240/415 V MCB of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required.GROUP 1 Single pole MCB 6 A to 32 A rating |
| 54 | Four pole MCB 40 A 63 A rating |
| 55 | Double pole MCB 6 A to 32 A rating |
| 56 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 20 mm |
| 57 | 25 mm |
| 58 | Providing & Fixing of 1200 mm sweep BLDC technology power saving ceiling fan which can withstand on votage fluctuations from 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 220 CMM, speed minimum 330 RPM ( tolerance as per IS:374 2019 ) THD less then 10% and complete with down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe up to 80 cm , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .With 3 Star |
| 59 | P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required 5 step fan regulator 2 Module |
| 60 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .570mm (+/-10%) batten with min. lumen output 1000 lm |
| 61 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR4 Way (4+2) |
| 62 | P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 6.0 Sq.mm 3 core flat / Round Please Enable Macros to View BoQ information |