Tender For Construction Of 08 Roomed Double Storey Building At Bhss Lalpora Advertised Cost: 349.38 Lacs.
Tender Value
3.49 Crore
Estimated cost
Bid Submission
10 Jul 2026
8 days left
EMD
7 Lakhs
Bank guarantee accepted
Document Fee
5500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kupwara → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 08 Roomed Double Storey Building At Bhss Lalpora Advertised Cost: 349.38 Lacs.
BOQ
| Sl. No. | Item Description |
| 1 | Part A Civil Work:Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains,pipes,cablesetc.(notexceeding1.5minwidth) andforshafts,wells,cesspitsandthelikenotexceeding 10 sqm on plan, including dressing of sides and rammingofbottoms lift upto1.5m, includinggetting out excavatedearthanddisposal of surplus excavated earthasdirected,withinaleadof50metres:(Allkinds of soil) |
| 2 | Providing and laying of stone soling/boulders (Hand Packed) including ramming, dressingandwateringall complete.(Incl. all sorts of carriage) |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level.1:4:8(1cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal) crushed. |
| 4 | Providing and laying in position specified grade ofreinforced cement concrete including curing butexcluding the cost of centering, shuttering, finishingand reinforcement. All works upto plinth level 1:1½:3(1 cement : 1½ coarse sand : 3 graded stone aggregate20 mm nominal size) |
| 5 | Reinforced cement concrete work in walls (anythickness) including attached pilasters, buttresses,plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts upto floor five levelincluding curing but excluding cost of centeringshuttering, finishing and reinforcement. 1:1½:3 (1cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) |
| 6 | Reinforced cement concrete work in beams,suspendedfloors, roofs having slope upto 15°, landings, balconies,shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases upto five level includingcuring but excluding the cost of centring, shuttering,finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stoneaggregate 20 mm nominal size) |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo- Mechanically Treated bars of grade Fe-500D or more. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns for mass concrete |
| 11 | Centering & Shuttering incl. strutting, propping etc. & removal of form work for Walls (any thickness) including attached pilasters, buttresses, plinth andstring courses etc. |
| 12 | Centering & Shuttering incl. strutting, propping etc. & removal of form work forColumns, pillars, piers, abutments, posts and struts. |
| 13 | Centering & Shuttering incl. strutting, propping etc. & removal of form work for Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 14 | Centering & Shuttering incl. strutting, propping etc. & removal of form work for Suspended floors, roofs, landings, balconies and access platforms. |
| 15 | Centering & Shuttering incl. strutting, propping etc. & removal of form work for Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 16 | Centering & Shuttering incl. strutting, propping etc. & removal of form work for Stairs (excluding landings) except spiral staircases |
| 17 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in superstructure above plinth level upto floor five level including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 18 | CEMENT PLASTER (IN FINE SAND) 12 mm Cementplaster of mix:1 : 6 ( 1 cement : 6 fine sand) External |
| 19 | CEMENT PLASTER (IN FINE SAND) 15 mm Cementplaster of mix:1 : 6 ( 1 cement : 6 fine sand) Internal |
| 20 | Extra for plastering done on moulding cornices or architraves including neat finish to line and level : In two coats |
| 21 | Providing and laying autoclaved aerated cement blocks masonry with150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesivemortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcementshall be made for separately). |
| 22 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete: 50mm thick with 20mm nominal size stone aggregate |
| 23 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 24 | Providing and applying white cement based putty of specified thickness, of approved brand andmanufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 25 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 26 | Marble work gang saw cut (polished and machine cut) of thickness 16 mm for wall lining (veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 (1 cement: 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately). (Area of slab upto 0.5 sqm) |
| 27 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc.including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work |
| 28 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 29 | Providing and laying Ceramic glazed floor tiles300x300 mm (thickness to be specified by themanufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand)including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown |
| 30 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 31 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process ofrequired length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gapbetween frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm &sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) |
| 32 | Providing and Fixing factory made UPVC door frame, made of UPVC extruded sections , of size 65 mm x 55 mm with wall thickness 2.0 mm ( ± 0.2 mm) , corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (±0.2mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fasteners, all complete as per manufacturer’s specification and direction of Engineer-in-charge. |
| 33 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of : 12 mm thick pre-laminated particle board (decorative lamination on one side and other side balancing lamination) grade-I, medium density flat pressedthree layer particle board FPT-I or graded wood particle board FPT-I, IS: 3087 marked, bonded with BWP type synthetic resin adhesive as per IS: 848 and prelaminated conforming to IS: 12823, Grade-I, Type-II marked |
| 34 | Providing and fixing float glass panes 4 mm thick glass pane (weighing not less than 10 kg/sqm) |
| 35 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded |
| 36 | Providing corrugated G. S. sheet tile profile roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat ofapproved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the costof purlins, rafters and trusses and including cutting tosize and shape wherever required. 0.5 mm thick withzinc coating not less than 275 gram/m2 of require shadeand colour as per engineer in charge. |
| 37 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gram/m2 |
| 38 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 39 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 40 | Painting steel work with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 41 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 42 | P/F of 60mm thick factory made interlocking tiles over 50mm tick compacted sand cusion complete job as per directions of EIC |
| 43 | Supply and installation of satin finish stainless steel 304stainless steel Posts having 100mm dia tube, erectedwith chemical grout to be fixed on the top ofslab/skirting (Spigot Fixed) at corners complete, asmanufactured by Dline or approved equivalent & shallbe fixed above the finished level complete as perarchitectural drawings. |
| 44 | Part B Sanitary and PlumbingProviding and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. PN-16 pipe, 25mm OD(SDR-7.4) |
| 45 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.PN-16 pipe, 32mm OD(SDR-7.4) |
| 46 | Supply, installation, testing and commissioning of gunmetal, male or female threaded isolation control valve of approved quality confirming to IS 778, PN 10, with necessary specials, unions, nipple etc., |
| 47 | 25mm dia |
| 48 | 32mm dia |
| 49 | Providing and fixing PPR Unions:PPR Union 32mm |
| 50 | Providing , fixing & laying G.I. pipes Medium type complete with G.I. fittings and clamps, incluing trenching and refilling (external work) 25mm dia |
| 51 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings. Flat back wash basin of size 630x450 mm. |
| 52 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 53 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 31mm of 79 mm length and 62 mm breadth weighing not less than 45gms. |
| 54 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 55 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 56 | Providing and fixing mirror of superior glass( of approved quality) and of required shape and size with plastic . moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape1500x450 mm. |
| 57 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 58 | Providing and fixing water heater (Geyser) of standard quality and make as approved by EIC 50ltr |
| 59 | Providing & Fixing C.P. Single hole mixer for wash basin. |
| 60 | Providing & Fixing C.P. wall mixer of approved make including cutting and making good the walls wherever required. Jaquare |
| 61 | Providing & Fixing C.P. tubes of approved make 450mm to 600mm long. |
| 62 | Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms |
| 63 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 64 | Providing and fixing P.V.C. pipe and pipe fittings of thefollowing nominal dia to P.V.C. Soil/Waste/Ventilatingpipes, excluding cost of holder-bats. |
| 65 | Pipe 100mm |
| 66 | Floor trap 100mm |
| 67 | Door T 100mm |
| 68 | Collars 100 mm |
| 69 | Reducer 100 x 50mm |
| 70 | Pipe 75mm |
| 71 | Floor trap 75mm |
| 72 | Door T 75mm |
| 73 | Collars 75 mm |
| 74 | Pipe 50mm |
| 75 | Cone covel 50mm |
| 76 | PVC waste pipe |
| 77 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominalsize),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design. Inside size 90x80 cm and 45 cm deep includingC.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 78 | Providing and fixing of master trap of approved quality and make. |
| 79 | Providing and fixing of 6-layer water storage tanks of approved quality and make. |
| 80 | Carriage of materials by Mechanical Transport including loading, unloading and stacking. |
| 81 | Stone aggregates |
| 82 | Bricks Average lead of 120km |
| 83 | PART B Electrical :Wiring for Light point/Fan point/Exhaust fan/Bell point with(P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells/Anchor/Eq Make) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 25mm) with 01 No.of 6 Amp Modular Switch, Modular Plate, Cover in 224 front & suitable GI box etc ISO/EC Certified/Schneider/ Havells/ Legrand/Anchor roma plus ABB Eq.Make & along with 2.5 Sqmm (P+N+E) Circuit Wire of same make as mentinoned above & items shall be approved before execution of work by SDO. |
| 84 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required, ISO/IECCertified of Havells/ Legrand/Anchor/Schneider /ABB/Eq Make & shall be approved before execution of work by SDO. |
| 85 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVCInsulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Anchor/Eq Make) |
| 86 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISEC Certified/Legran/Anchor roma plus/Schneider/ABB/Eq Make & shall be approved before execution of work by SDO |
| 87 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mmFRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Anchor/Eq. Make) |
| 88 | Supplying and fixing suitable si. : GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non. residential buildings), ISO/IEC Certified Havells/Legrand/ Anchor roma plus Schneider/ABB/Eq.Make & shall be approved before execution of work |
| 89 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Anchor/ Eq Make) & shall be approved before execution of work (Including Cost of Conduit/Channel) |
| 90 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 91 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 92 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 93 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 94 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,C Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB. DB Complete with connections. (L&T/Siemens/Legrand/Havells/ABB/Eq.Make) |
| 95 | Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections.(L&T/Siemens /Legrand/Havells/ABB/Eq Make) |
| 96 | 63 Amp |
| 97 | 40 Amp |
| 98 | 32 Amp |
| 99 | Supplying and Fixing of MCB way 6-way (4 + 18), horizontal typed, sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider/ABB/Eq Make) |
| 100 | Supply/Installation/Testing and Commissioning of 18W + LEDConceal/Surface (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 Im/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70..The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/Havell's/Wipro/Halonix/Eq Make. |
| 101 | Providing & Fixing of 1K0X IP-66 protected high power LED 50 Watt flood light yotem with single prece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 walt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >-125 Im/wt. LED driver Input Voltage AC: 120 to 270 V AC with High voltage Cutoff (@=300 V AC and Auto resetting Safety Power Factor >0.95, THD() <10%, driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector.Surge Protection Min >-4K V internal and 10K V external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allowtraceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures.(IM79/M80) Certificate/ report with liable warranty of product/accessories fromOEM shall be submitted. All as per pre approved by Engincer in charge. For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/t of suitable size of Gyser bolt. The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning handing over of site to intending department. |
| 102 | Supply, Installation, Testing and Commissioning of decorative 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete. USHA Striker/Havells Oyster matalic/CromptonAura/equivalent make as directed by engineer incharge. |
| 103 | Supply/Installation/Testing and Commissioning of 225-250mmShutter Typed,320 Cum/HrAC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection ete USHA/Havells/Crompton/Eq. Make.(Min 1- star) |
| 104 | Supply/Laying/Connecting and Commissioning of 70 sq.mm 3.5-CoreXLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-l and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth oi 50 CM including excavation and Reilling the Trench (Material to be approved before execution) |
| 105 | Supply/Installation/Testing and Commissioning of CPRI Approved (IS/I:C:61439) Muin Controlling Panel, fabricated out of heavy gauge sheet steel dully Painted with powder coated paint dust protected ,carth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT|Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified. The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/ L&T/Legrand/ Schneider Make.(1) Normal Incomer:a) 200 Amp-4-Pole ,56kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider Make as approved-01 No.b) 400 Amps TPN Al. Bus Bar Set - 01 Set, Digital Voltmeter Ammcter,C.T Coils with Selector Switch & Phase indicator Set.125 Amp. 4-pole changeover tp bypass between main supply and generator supply.Outgoing:(1) Nornal outgoing for Heating/AC/Lighting/Inverter etc load(a) 63-Amp DP MCB - 06 No. for Heating Sub-main.(b) 40-Amp DP MCB- 06 No. for Lighting/Machine Sub-main(e) 32-Amp DP MCB - 08 No. for inverter Sub-main and AC Sub-main |
| 106 | ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPERRod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value .Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystallineconductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of20MM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAINControl PANELthrough DWC High Density Poly ethylene Pipehaving Corrugation complete job |
| 107 | Supply Installation Testing & Commissioning of 3 Star rating 1.5TON inverter type split Air Conditioning system suitable for operation on AC supply single phase 220 V The indoor unit fitted on wall by employing suntable clamps and the outdoor unit fitted on the wall by using suitable angle iror stand fitted with nuts/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ pvc insulated coper cable and a battery operated wireless remote unit. the job also includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning. ‹ O-General make) including cost of 3 KVA Digital Auto control VOLTAGE Stabilizer for ACs of Approved brand for smooth functioning/ constant voltage supply having etc Input voltage= 90-220 volts & output voltage=220 volt & stand Copper piping ete & all other allied accessories. installation charges. GST, income tax, Carnage ete Complete job The job includes CMC (reckoned from date of successful commissioning) for a period of Two years. |
| 108 | Supply & fixing of Modular AC box with 32 AMP Single pole MCB of havels/ legrand/Schneider/L&T make |
| 109 | Supply installation testing, & commissioning of 50 KVA 3 -Phase SERVO controlled VOLTAGE Stabilizer of Approved brand with following SPECIFICATIONS :(1). INPUT VOLTAGE: 156 Volt -450 Volts P-P (90V-260V N-P)(2) OUT PUT VOLTAGE : 400Volts+ 1%(230VAC)(3) Winding Material Insulation : 99.97% PURE COPPER WOUND FIBER GLASS(4). IN DOOR TYPE(5). COOLING OIL IS 335(6).MICRO CONTROLLED TRUE RMS Based LCD display(7). Protections are Over LoadCOPPER wound of Electric Field /Alba /AE /Cosco/Eq.make etcISI/ISO certified for smooth functioning/ constant voltage supply having Technical Specifications :Input voltage= 90-260 volts & output voltage=220 volts+ - 2% Buck Boost Transformer Copper wound 99.9% OIL ImmersedCOOLING OIL High cut/Low Cut /Time delay / Over Cut through Micro Control and Spike Protection including ,Carriages ,installation charges, testing & taxes complete job alongwith servo bypass switch of adequate rating. |
| 110 | Supply/Installation/Testing and Commissioning of 100 Amp Four Pole manual bypass changeover switch of Havells / Siemens/ ABB /Schinder /L&T/Eq make |
| 111 | Supply and fixing of PVC ceiling rose (2/3 pin), ISI marked, suitable for connection of light/fan point, complete with necessary accessories, including connections and testing as required of Havells/Anchor/Legrand/Eq.make |
| 112 | Supply and fixing of Hylum sheet (phenolic laminated sheet), 3 mm / 6 mm / 10 mm thick (as specified), duly cut to required size and shape, fixed with necessary nuts, bolts, 700+ screws, washers, spacers etc., including finishing and making good the surface, complete as required Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysJul 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 days