| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE SOUTH SECUNDERABAD Name of Work: REPAIR/REPLACEMENT AND CLEANING OF SEWAGE LINE, MAN HOLES , SEPTIC TANKS , FILTER BED, ETC OF OTM AND MD ACCN AT ACHARYA ENCLAVE, THIMMAYYA LINE GP ENCLAVE ASHA COLONY, ROBERT LINE, ROBERT WEST, ROBERT CENTRE, MEADOWS LINE AND BSO FURNITURE YARD UNDER AGE B/R (S) NO.I OF GE (S) SECUNDERABAD. Contract No: GE(S)/SEC/TOKEN -48 OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Item Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | De-sludging and cleaning of septic tank, manhole, sludge chamber etc by manual digging out and lifting of concerntrated sludge including dewatering and cleaning, removing silt, sludge , sludge water and any other foreign materials and depositing the same into excavated pits exceeding 1.5m depth at places ( n exc 100m) as directed by the Engr-in-Charge returining and filling in excavated earth after depositing sludge including sludge water and sprinkiling bleaching powder over surrounding area and removing surplus excavated soil nearby areas complete all as specified and as directed. Note : Measurement shall be made for sludge incl sludge water. |
| 3 | M&L for Cleaning of all blockages of any type of sewage line ie branch sewer line, main sewer line etc, manholes of any size, section and depth, any situation by way of cleaning/desludging manholes by using any type either manually, mechanically or by way of any other suitable means including foreign materials as well as rodding of sewer lines and between successive from block manholes where required and ordered by Engineer-in-charge and keeping the sewage line functional duly cleaning trap, water closet, soil water/vent pipe, gully traps upto final drop free flow in to out let,septic tanks or central sewage system treatmenting in other adjoining Zone/Area or into sewage well (working in foul condition with taking precautionary measures) equipment as required or applicable and removing the sludge/material and depositing outside the MOD land complete all as specified and as directed.NOTE Approximate quantity required to clean per month in entire area as under: (a) 100 mm dia sewage line - 120 Metre (b) 150 mm dia sewage line 2000 Metre (c) 200 mm dia sewage line - 400 Metre (d) Manholes 1.0 x 1.0 Metre size - 220 Nos (e) Manholes 1.20 x 1.20m size - 80 Nos (f) EWC/IWC, Nahani trap, gully trap, floor traps - 200 Nos. |
| 4 | M&L for Cleaning of chocked sewer line of any description by mechanically driven vechile system and flushing with water for 150mm/200mm dia size of pipe.complete all as specified and as directed.Note:-Payment shall be done based on actual ground measurement taken while cleaning blokage of sewage line |
| 5 | M&L for Mechanically pumping out sewage water from Septic tanks/sump well where required and as directed with taking precautionary measurers including tools & plants as required and removing to place out side MOD land from the site (working in foul condition) complete all as specified and as directed.Note:-Payment shall be done based on actual ground measurement taken while cleaning blokage of septic tank/ sump |
| 6 | Excavation in trenches by mechanical means (Hydraulic excavator) n.exc. 1.5m wide and n.exc. 1.5m in depth for taking up/laying sewer lines and getting out in any kind of soil complete all as specified and as directed. |
| 7 | All as per item No.05 above but exc. 1.5m and n.exc. 3.0m deep complete all as specified and as directed. |
| 8 | Returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm complete all as specified and as directed. |
| 9 | Removing of excavated soil to a distance n.exc 50m and depositing where directed at alevel n.exc 1.5m above starting point complete all as specified and as directed. |
| 10 | Demolition and breaking up drain pipes 100mm dia ( Salt Glazed ware, AC or reinforced concrete) set in cement mortar including PCC bed and haunching and removal of debris outside the MD land complete all as specified and as directed. |
| 11 | All as per item No.9 above but 150mm dia. complete all as specified and as directed. |
| 12 | All as per item No. 09 above but 200mm dia. complete all as specified and as directed. |
| 13 | M&L for Salt Glazed Stoneware pipes grade 'A',100mm bore,laid in trenches and jointed set in cement mortar and removal of debris outside the MD land complete all as specified and as directed. |
| 14 | M&L for Reinforced concrete pipes, class NP2,150mm bore, laid in trenches and jointed complete with collars set in cement mortar and removal of debris outside the MD land complete all as specified and as directed. |
| 15 | M&L for Reinforced concrete pipes, class NP2,200mm bore, laid in trenches and jointed complete with collars set in cement mortar and removal of debris outside the MD land complete all as specified and as directed. |
| 16 | M&L for PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) for bed to drain pipe 100mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 17 | M&L for PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) for bed to drain pipe 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 18 | M&L for PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) for bed to drain pipe 200mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 19 | S&F in repairs for 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall/trenches etc using synthetic rubber adhesive cement solvent complete all as specified and as directed. |
| 20 | S&F for 110mm dia PVC (SWR) band any radius complete all as specified and as directed. |
| 21 | S&F for 110mm dia PVC (SWR) bends with acess door any radius complete all as specified and as directed. |
| 22 | S&F for 110mm dia PVC (SWR) branch piece single (Single T ) equal or unequal complete all as specified and as directed. |
| 23 | S&F for 110mm dia PVC (SWR) vent cowl complete all as specified and as directed. |
| 24 | S&F in repairs for 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall/trenches etc using synthetic rubber adhesive cement solvent complete all as specified and as directed. |
| 25 | S&F for 75 mm dia PVC (SWR) grade bends of any radius complete all as specified and as directed. |
| 26 | S&F for 75 mm dia PVC (SWR) grade bends with acess door of any radius complete all as specified and as directed. |
| 27 | S&F PVC (SWR) branch piece, single (SingleT ) of radius equal or unequal, 75mm dia complete all as specified and as directed. |
| 28 | S&F PVC (SWR) vent cowl, 75mm dia complete all as specified and as directed. |
| 29 | Demolition of RCC cover slab for manholes etc complete all as specified and as directed. |
| 30 | M&L for pre-cast reinforcement cement concrete (1:2:4) Type B-1, using 20 mm graded crushed stone aggregate as in cover slab for manholes etc.and set in cm 1:6 complete all as specified and as directed.. |
| 31 | S&F TMT bars 10 mm dia and over and cut to length bent to shape required including cranking, bending, hooking ends and bending with MS wire not less than 0.9mm dia or securing with clips quality conforming complete all as specified and as directed. |
| 32 | Demolition of Bricks or stone masonry built in cement mortar complete all as specified and as directed. |
| 33 | M & L for brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM (1:4) as in manholes, septic tank, filter bed, walls, drains etc complete all as specified and as directed. |
| 34 | M&L for Pre-cast cement concrete block masonry with solid blocks type C1 (1:3:6) (20mm graded stone aggregate) set in CM 1:6, exc. 10 cm in width and setting in mortar, complete all as specified and as directed. |
| 35 | Taking down cement plaster on brick or stone masonry wall etc incl racking out joints haking for key, scrubbing down with water etc as in external surfaces of man holes, septic tank, filter bed etc incl removing of debrie complete all as specified and as directed. |
| 36 | M & L rendering 15mm thick on brick or concrete surfaces of walls in CM (1:4) including finishing the surfaces even and smooth without using extra cement as in manholes, septic tank, filter bed out let drain by using water proofing compound etc all as directed by Engineer-in-Charge. |
| 37 | Supply of Integral waterproofing compound complete all as specified and as directed. |
| 38 | Demolition of cement concrete (un-reinforced ) in ground floors and pavings not exceeding 15cm thick(below or above ground level ) complete all as specified and as directed. |
| 39 | M&L PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified & directed. |
| 40 | M & L Plain cement concrete type-B1(1:2:4) (using 20mm graded crushed stone aggregate ) as in benching coping etc incl necessary form work.complete all as specified and directed. |
| 41 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and as directed. |
| 42 | M&L for 75 mm thick plain cement concrete type D-2 (1:4:8) (40 mm graded crushed stone aggregates) as in sub base complete all as specified and as directed. |
| 43 | M&L for 50mm thick plain cement concrete in (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in plinth protection finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed. |
| 44 | S&F for chequered cement concrete tiles 30cmx30cmx25mm thick with grey cement and pigment set jointed and pointed in neat cement slurry laid over and including 20 mm thick screed bed of cement mortor (1:6) in floors complete all as specified and as directed. |
| 45 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method usingPU mould, laid in required colour & patternover and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. Total in Figures 23 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |