| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Repairs to brick work, retaining wall, traverse, earth filling, repair to vent pipes in technical area and connected work including smart periodical in 2 ASD area under GE Kapurthala Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc; complete all as specified and as directed. |
| 3 | Dismantling of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlars facings, dressed stonework and precast concrete articles, complete all as specified and as directed. |
| 4 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls finished even and smooth without using extra cement, complete all as specified and as directed. |
| 5 | M&L for rendering 10mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 on walls finished even and fair without using extra cement, complete all as specified and as directed. |
| 6 | M&L for rendering 10 mm thick in cement and sand mortar 1:4 on brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement incl water proofing compound complete all as specified. (water proofing compound @ 3% by weight of cement and will be measured and paid separately) |
| 7 | M&L for rendering 5mm thick on fair faces of brick or concrete surfaces in cement mortar 1:3 on ceiling finished even and smooth without using extra cement, complete all as specified and as directed. |
| 8 | M&L for preparation of new plastered surfaces of wall and applying tow coat of weather proof coat over a coat of primer complete all as specified and directed. |
| 9 | M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over and including a coat of chalk whiting/priming on plastered surfaces of walls, complete all as specified and as directed. |
| 10 | M&L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over and including one coat of appropriate primer complete all as specified and as directed. |
| 11 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of white wash over and including a coat of primer complete all as specified and as directed. |
| 12 | M&L for brick work with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 13 | - ditto - all as per item No.11 above but except bricks etc; including cleaning of bricks form mortar complete all as specified and directed. |
| 14 | M&L for brick work with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 15 | Demolition of concrete (unreinforced) of any description and any size or type complete all as specified and directed. |
| 16 | M&L for PCC type B-1 (1:2:4) (using 20 mm graded crushed stone aggregate) as in parapets walls, benching, coping and filling at junction of brickwork and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete including use of formwork (straight or curved) all as specified and directed. (water proofing compound @ 3% by weight of cement and will be measured and paid separately) |
| 17 | M&L for cement concrete type B1, 1:2:4 (20mm graded stone aggregate) in floor complete all as specified and directed. |
| 18 | M&L for cement concrete type D2, 1:4:8 (40mm graded stone aggregate) as in floor, foundations, filling and mass concrete, complete all as specified and directed. |
| 19 | Supply only Integral water proofing compound. |
| 20 | Uprooting of tree roots from walls/roof of any girth at any height/location of any depth by dismantling brickwork / PCC and making good the damaged portion as existing by PCC 1:2:4 type B-0 and finished with 15mm thick plaster in 1:4, complete all as specified and directed. |
| 21 | Demolition of RCC chajjas and reinforcement concrete of any description including facilitate in cutting of reinforcement and removing rubbish off the premises of cantonment complete all as specified and directed. |
| 22 | M&L for RCC 1:1 ½:3 , type A-0, using 12.5 mm nominal size graded crushed stone aggregate as in chajjas, roofs, landings, balconies, canopies, deck slabs, shelves and any similar work complete all as specified and directed. |
| 23 | Use & waste formwork for ground floor and 1st floor to soffits of suspended slabs such as roof slabs, floor slabs, chajjas, landings up to 6m height and similar work of concrete complete all as specified and directed. |
| 24 | Cutting grooves in brick wall, 75mm wide and 65mm deep for shelves, chajjas and similar work including for inserting TMT bar as required length and shaping horizontal/vertical face of groove making good where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good complete all as specified and directed. |
| 25 | S&F of 10mm dia and over TMT bars as in reinforcement, cut to length, bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia or occurring with clips complete all as specified and directed. |
| 26 | M&L for preparation of old decorated concrete surfaces of road side curb stone by complete removal of existing treatment by applying water and scrapping of entire thickness of existing treatment with using steel scraper and thereafter applying two coat of colored road paint (Yellow & Black in alternate layer) over a coat of appropriate primer complete all as specified and directed. |
| 27 | M&L for preparation of existing surface & re-writing letters or figures (Block, Roman, Italic or Indian) n.exc. 30cm high with synthetic enamel paint including repainting of number plates complete all as specified and directed. |
| 28 | M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed. |
| 29 | M&L for treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 to match the existing floors complete all as specified and directed. |
| 30 | Taking down rain water pipes (any size and pattern), including all fittings, heads, shoes, bends, swan necks, etc. removal from site (measured overall as fixed along the centre line or fittings and accessories) complete all as specified and directed. |
| 31 | S&F of PVC rain water pipes (SWR) 110mm dia single socketed, in any length with rubber joints, fixed to walls with flat iron clamps complete all as specified and directed. |
| 32 | S&F of 110mm bore PVC pipe (SWR) as in weep holes complete all as specified and directed. |
| 33 | Excavation over areas in any type of soil, n exc 1.5 m deep and getting out complete all as specified and directed. |
| 34 | Excavation over areas in any type of soil, exc 1.5 m deep and n exc 3.0 m deep and getting out complete all as specified and directed. |
| 35 | Excavation over areas in any type of soil, exc 3.0 m deep and n exc 4.5 m deep and getting out complete all as specified and directed. |
| 36 | Excavation over areas in any type of soil, exc 4.5 m deep and n exc 6.0 m deep and getting out complete all as specified and directed. |
| 37 | Returning filling in incl spreding levelling watering and well ramming in layers not exc 25 cm upto 6.00 m height complete all as specified and directed. |
| 38 | Removing excavated material (soil) not exc. 50 mtr and depositing where directed at a level n.exc. 1.50 mtr above the starting point complete all as specified and directed. |
| 39 | Rough excavation in any type of soil, n exc 1.5 m deep and getting out complete all as specified and directed. |
| 40 | Removing excavated material (soil) exc 5.00 Km but not exc. 15 Km and depositing where directed complete all as specified and directed. |
| 41 | Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base, complete all as specified and directed. Note:- 90% compaction factor is considered and compacted thickness will be paid to the contractor. |
| 42 | - ditto - all as per item No.40 above but height exc 1.5m from the base but n.exc 3.00m height complete all as specified and directed. |
| 43 | - ditto - all as per item No.40 above but height exc 3.00m from the base but n.exc 4.50m height complete all as specified and directed. |
| 44 | - ditto - all as per item No.40 above but height exc 4.50m from the base but n.exc 6.00m height complete all as specified and directed. |
| 45 | Demolition and breaking up 450mm bore RCC pipe set in cement mortar and taking out from trenches complete all as specified and directed. |
| 46 | M&L for reinforced concrete pipes for 450mm internal dia, class NP-2, laid in trenches and jointed complete with collar complete all as specified and directed. |
| 47 | M&L for reinforced concrete pipes for 450mm internal dia, class NP-2, laid in trenches and jointed complete with collar complete all as specified and directed. (but except RCC pipe) |
| 48 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 49 | S&F for Plates (plain or chequered), square cut or notched (ordinary and counter sunk) forming holes, with or without any attachment incl necessary running welding complete all as specified and directed. |
| 50 | M&L for mild steel work as in rolled section as in in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc; complete all as specified and directed.Fe-290 (Gde E165). |
| 51 | Preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 52 | M&L for complete removal of existing treatment on wall/roof projections including facia, cornices etc by scrapping to make surface clean, free from dust, loose paint etc by skilled labour complete all as specified and directed. Note:- Cost of scaffolding upto 10m height of building shall be included in the quoted rate. |
| 53 | M&L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & color stay technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, anti algal properties in two coats @ 1.79 litre (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint complete all as specified and directed. Notes:- (a) The work pertaining to periodical services shall be executed by authorized applicator through manufacturer of which the materials ie; paint, distemper etc. is proposed to be used by the contractor and approved by GE.(b) Cost of scaffolding upto 10m height of building shall be included in the quoted rate.(c) The contractor shall upload alongwith tender documents under Cover-I, 'Memorandum of Understanding' (MOU) with only one manufacturer mentioned in the contract, failing which the bid shall be liable to be rejected. |
| 54 | M&L for waterproof cement based putty of thickness 1 mm over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface to make the surface free from dust, allow 6-8 hrs time to dry the putty etc by skilled labour as per following steps:-Note:- Cost of scaffolding upto 10m height of building shall be included in the quoted rate. |
| 55 | M&L for applying two coats of oil bound distemper using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed.Note:- (a) Sanding of surface to be done by mechanical sander with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paint application.(b) Cost of scaffolding upto 10m height of building shall be included in the quoted rate. |
| 56 | M&L for preparation of old decorated surfaces of walls and applying one coat of exterior emulsion paint/weather proof coat complete all as specified and directed. |
| 57 | M&L for preparation of old decorated surfaces of walls and applying one coat of exterior emulsion paint/weather proof coat of camouflage pattern complete all as specified and directed. |
| 58 | M&L for preparation of old decorated surfaces of walls or cornice by complete removal of existing treatment by applying water and scrapping of entire thickness of existing treatment with using steel scraper and thereafter applying two coat of exterior emulsion paint/weather proof coat over a coat of primer complete all as specified and directed. Note:- Exterior emulsion paint to be done by Roller. |
| 59 | M&L for preparation of old decorated surfaces of walls or cornice by complete removal of existing treatment by applying water and scrapping of entire thickness of existing treatment with using steel scraper and thereafter applying two coat of exterior emulsion paint/weather proof coat over a coat of primer of camouflage pattern complete all as specified and directed. Note:- Exterior emulsion paint to be done by Roller. |
| 60 | M&L for preparation of old decorated surfaces of walls and cornice by complete removal of existing treatment by applying water and scrapping of entire thickness of existing treatment with using steel scraper and thereafter applying 2mm wall care putty to achieve smooth finish complete all as specified and directed. |
| 61 | M&L for preparation of old plastered surfaces of wall and applying one coat of distemper oil emulsion complete all as specified and directed. |
| 62 | M&L for preparation of old plastered surfaces of wall and applying two coat of distemper oil emulsion complete all as specified and directed. |
| 63 | M&L for preparation of old surfaces shall include brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent and salts and applying one coats of cement based paint complete all as specified and directed. |
| 64 | M&L for preparation of old surfaces shall include brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and applying two coats of cement based paint complete all as specified and directed. |
| 65 | M&L for preparation of old plastered surfaces of ceiling and applying two coats of white washing complete surfaces complete all as specified and directed. |
| 66 | M&L for preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 67 | M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |