| 1 | Erection of structure/equipments along with all accessories as per technical specification and instruction manual including shifting of material from store to site & back to store. |
| 2 | 36 KV Vaccum Circuit Breaker with structure. |
| 3 | 36 KV C.T with structure. |
| 4 | 33 K.V. C.T Junction Box . |
| 5 | 36 KV P.T with structure. |
| 6 | 33 K.V. P.T Junction Box |
| 7 | 36 KV Line Isolator with Post Insulator (with required jumpering work) |
| 8 | 36 kv Bus Isolator with Post Insulator (with required jumpering work) |
| 9 | Main & Auxilary Sub-Station Structure (ALP, ABL, CCM, CGM, AKR, EKR, XPM, YMM) |
| 10 | Modification of various type substation structure by cutting and drilling of holes with welding work etc. as per site requirements. (if required) |
| 11 | Stringing of main bus X3 phase (moose conductor) up to 20 mtr in length along with all required work to complete the job. |
| 12 | Stringing of transfer bus X3 phase (panther conductor) up to 20 mtr in length along with all required work to complete the job. |
| 13 | 33 kv Bay wise interconnection of equipments with specified conductor (All jumpering work) |
| 14 | Laying of 1.1 kv control cable including all associated work to complete the job. |
| 15 | 2 Core X 2.5 sq mm |
| 16 | 4 Core X 2.5 sq mm |
| 17 | 6 Core X 2.5 sq mm |
| 18 | Erection of 33KV Tripple feeder C&R Panel as per proper alingment & direction of S/S Incharge with making earthing by MS Flat 50x6 mm at Control Room of 132KV S/S Rasoolabad Kanpur Dehat. |
| 19 | Termination of control cable of 33 kv bay (Control & relay panel ,VCB, C.T., P.T, Energy meter) including cost of cable glands ,ferrule and lugs as per site requirment. |
| 20 | Configuration and complete testing of 33 kv O/C and E/F relay as per UPPTCL specfication . |
| 21 | 33 kv Bay integration in the existing ALSTOM scada system and real time data validation to SLDC Lucknow also ICD & CID file configration of the relay required material provided by contractor. |
| 22 | Making of earthing of above S/S structure, Isolator, C.T.,P.T. VCB, Junction box by M.S. Flat (25x6 mm & 50x6 mm & 75x10 mm) size as per site requirment. ( M.S. flat provide by UPPTCL). |
| 23 | Earthing by (25X6 mm) MS Flat. |
| 24 | Earthing by 50X6 mm MS Flat |
| 25 | Earthing by 75x10 mm MS Flat |
| 26 | Painting of M.S. flat (25X6, 50X6 & 75X10) mm by one coat red oxide and two coat bus green colour after cleaning/remove rust work. |
| 27 | Providing and fixing of 33KV Feeder name plate of 2mm thick aluminium sheet plate size 400x300 mm with covering retro reflexion sheet base yellow colur & write feeder name in black colour. |
| 28 | Carriage of miscellaneous items ie VCB, BSI, LSI, MS Flat, ALP, ABL, CCM CGM, 33KV C&R Panel etc. near about (0 to 80 KM approx) the job icncudes shorting, coutnting, loading and unloading the same at 132KV S/S Rasoolabad,Kanpur Dehat via suitable private carriar. |
| 29 | Making of Delt Earthing by 36/40mm dia MS round bar and MS Strip of size 75x10MM in at near bay. The job includes making of 3 nos electrodes 03 mtr long boring/inserting work in 0.5 mtr below the ground level including laying and welding work and connect with Bay of MS Strip of size (75x10 & 50x6) mm from electrodes laying approx distance of 1.50 mtr and all associated work to complete the job satisfactonly in all respect. |
| 30 | Providing and fixing of AC Power Supply cubical of size 1000x700x400mm made by 16 SWG MS Sheet, having 3 Nos insulated aluminium bus bar of R,Y,B phase and 01 No insulated aluminium bus bar of neutral of size 25x10mm and 25x6mm respectively. The every cubical should have 01 Nos 125 Amp 04 Pole MCCB/ON/OFF switch and 32Amp 3 Phase with nuetral MCB for 04 Nos path of standard make ISI make. The cubical should have the provision of visual indication of incomming supply and indoor fitting 12 watt LED lamp. The power cubical shall be weatherproof, dust proof with proper arrangement with fixing on MS angle of size 45x45x6 mm by grouting at suitable/designated place in switchyard along with connecting of AC main power suply from ACDB to AC power cubical by laying of 2x12x2.5 sq mm copper control cable provided by the department on free of cost. |
| 31 | Providing and fixing of new generation energy & environment friendly long aluminum outdoor beam street light with high power (150 watt, 230 Volt) LED light (with one year guarantee with guarantee card with baar code) and also provide galvanised iron elbow with Philips/Havells make LED. The work includes fixing of light in Switchyard Pole/Gantry with required materials for fixing the LED fittings such as nuts, bolts & U-Bolts are to be also provided by the contractor. |
| 32 | Providing and fixing of double door type juction box with minimum 01 number 10 Amp single phase MCBs in each double door type, juction box (Hevells/Phillips/Anchor) make. The job including proper wiring & required cable laying and termination from LED Light fitting (Gantry) to Juction box and Juction box to AC Supply Cubicle for proper completion of work. |
| 33 | Making new earthmat near by construction place of 33KV Rasoolabad Link Bay by Laying of 36/40 mm dia MS Round Bar below ground level upto old Earth mat level. The job includes cutting, bending and electric welding & connect with exsisting earthmat and other assocated work. The work also involves inserting a three meter conical shaped 36/40 mm dai M.S.round bar into the ground at every alternate (cross) joints of the newly laid earth mat & properly weldind the joints.to complete the job satisfactory. |
| 34 | Fabrication of 50 Cm long cleat with 50X6 mm angel & welding at cross joints including cutting, welding work etc. |
| 35 | Supply (As per sample) |
| 36 | 05 Bolted type Gun fitting Sutaible for (Moose) Conductor. |
| 37 | 05 Bolted type Gun fitting Sutaible for (Panther) Conductor. |
| 38 | PG Clamps Sutaible for (Panther to Panther) conductor. |
| 39 | PG Clamps suitable for (Moose to Moose) Conductor. |
| 40 | PG Clamps suitable for (Moose to Panther) Conductor. |
| 41 | Copper Bond made of (16mm Dia wire) rope and 500mm Long with both end copper lug punched. |
| 42 | Terminal Connector of 36 kv Isolator suitable for Panther Conductor. |
| 43 | 33 KV (VCB clamp) suitable for twin panther conductor . Please Enable Macros to View BoQ information |