Tender For Addition, Alteration And Special Repair To The Office Of Cce(R&D) Estates South, Hyderabad
Tender Value
1.72 Crore
Estimated cost
Bid Submission
13 Jul 2026
9 days left
EMD
3.45 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ranga Reddy → Telangana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addition, Alteration And Special Repair To The Office Of Cce(R&D) Estates South, Hyderabad
BOQ
| Sl. No. | Item Description |
| 1 | REPAIR / ALTERATION WORK |
| 2 | Providing and fixing 18mm thick gang saw cut (premoulded and prepolished) machine cut Granite stone with area exceeding 0.5 sqm for kitchen platforms, vanity counters , window sills of approved shade, colour and texture over 20mm thick cement mortar 1:4 with joints treated with white cement, matched with matching pigments including rubbing, curing polishing to give high gloss. |
| 3 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 4 | Extra for providing edge moulding to granite stone 18mm |
| 5 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. |
| 6 | Granite Stone of approved shade |
| 7 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 8 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light trafic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 9 | 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern |
| 10 | Providing and fixing bevelled edge mirror of size 600 mm x 450 mm with 6 mm thick hard board at back and PVC moulded frame including all CP screws, etc complete. |
| 11 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 12 | Polished Granite stone slab of colour Black, Cherry Red, Elite Brown, Cat Eye or equivalent |
| 13 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P Type. |
| 14 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 15 | Providing and fixing soil, waste and vent pipes : |
| 16 | 75 mm diameter : Sand cast iron S&S pipe as per IS: 1729 |
| 17 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : |
| 18 | 75 mm dia pipe |
| 19 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : |
| 20 | 150 mm diameter |
| 21 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe |
| 22 | Providing and fixing anodised aluminium grills of approved design and pattern with approved standard section and fixed to existing window frame with CP / stainless steel screws @ 200mm c/c including cutting the grills to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement and directions of Engineer-in-charge |
| 23 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately). |
| 24 | Providing 12mm thick frameless toughened glass door shutter of approved brand and manufacture (Saint gobain/Asahi/Modi) including providing and fixing top and bottom pivot and spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete in all respect as per direction (Door handle, lock and stopper etc to be paid separately). |
| 25 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, bufng, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 26 | Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). |
| 27 | Providing and fixing at all height wall panelling with phenol bonded Bamboo Mat board conforming to IS:13958-1994 including providing and fixing to frame work made of 50 mm x 50 mm hard wood plugs including cutting brick work and fixing in cement mortar and making good the wall etc. And also providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws all complete as per direction of Engineer-in-Charge. 9mm thickness. |
| 28 | Providing and fixing ISI marked Flush door shutters 30mm thick conforming to IS:2202 decorative type, core of block board construction with frame of Ist class hardwood and well matched teak 3 ply veneering with vertical grains on both faces of shutters and ISI Marked Stainless Steel Butt Hinges |
| 29 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid or/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). |
| 30 | Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 31 | Frame size 45 x 70 mm |
| 32 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 33 | 30 mm thick |
| 34 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 35 | For fixed portion |
| 36 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 37 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 38 | Pre-laminated particle board with decorative lamination on both sides |
| 39 | Providing & fixing in position Phenol bonded Bamboo wood panelling of 10mm thick, in 25 to 40 mm thick panelled or panelled & glazed shutters for doors, windows, clerestorey windows, in approved colour, texture & finish. The bamboowood planks shall have minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. The panels shall have profiled interlocking system locked in place with bamboo pins all complete as per direction of the Engineer in-charge. (area of opening for panel inserts excluding portion inside grooves or rebatesto be measured) |
| 40 | Providing and fixing bright finished brass butt hinges of sizes: 125 x 85 x 5.5 mm (Heavy type) with necessary SS screws |
| 41 | Providing and fixing bright finished brass towes bolt of sizes 200 x 10 mm (barrel type) with necessary screws |
| 42 | Providing and fixing bright finished brass towes bolt of sizes: 150 x 10 mm (barrel type) with necessary screws |
| 43 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : |
| 44 | 300x16x5 mm |
| 45 | Providing and fixing bright finished brass 100mm mortice door latch and lock with 6 levers and a pair of lever handle with necessary screws. |
| 46 | Providing and fixing 125mm bright finished brass handles with necessary screws |
| 47 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. each |
| 48 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 49 | Providing and fixing pressed steel door frames conforming to IS: 4351 manufactured from commercial mild steel sheet of 1.60 mm thickness including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60 mm pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges, 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: |
| 50 | Fixing with adjustable lugs with split end tail to each jamb. |
| 51 | Providing and laying Glazed Ceramic floor tiles 300mx300mm ( thickness to be specified by manufacturer) of 1st Quality conforming to IS: 15622 of approved make and shade on cement mortar 1:4 ( 1 Cement : 4 coarse sand ) including pointing the joints with white cement and matching pigments etc complete |
| 52 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours, shades, laid on 20 mm thick bed of cemect mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc, complete. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 53 | Size of Tiles 600 x 600 mm |
| 54 | Glazed Vitrified tiles Matt/Antiskid finish of size |
| 55 | Size of Tile 600 x 600 mm |
| 56 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 57 | 110 mm diameter |
| 58 | Providing and fxing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, .the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, difusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 59 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 60 | White washing on ceiling with lime to give an even shade (Two or more coats) |
| 61 | Painting two or more coats with Synthetic enamel paint on steel surface of approved shade and manufacture over under coat of ordinary paint |
| 62 | Painting with synthetic enamel paint on wooden surface of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. |
| 63 | French spirit polishing :Two or more coats on new works including a coat of wood filler. |
| 64 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour including preparation of surface as directed by Engineer-in-charge. |
| 65 | Two Coats |
| 66 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 67 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) , including removal of existing treatment and preparing the surface by hacking to achieve key for plaster |
| 68 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand), including removal of existing treatment and preparing the surface by hacking to achieve key for plaster |
| 69 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge, including removal of existing treatment and preparing the surface by hacking to achieve key for plaster. |
| 70 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. |
| 71 | With cement mortar 1:4 (1cement: 4 coarse sand) |
| 72 | (a) Chipping the Screed Surface: Chipping the existing screed up to Mother slab (Sound surface) by Mechanical means and carting the same at ground floor at desired location (including taking out of existing treatment of any type).(b) Surface Preparation: The surface to be water proofed shall be perfectly clean and sound. Removing crumbly or loose parts, dust, cement laitance, form release agents, by mechanical Grinding, brushing, or high-water pressure as per the substrate condition.(c) Corner Treatment–Coving: Preparing the Coving at the junction of slab and vertical offsets with CM 1:3 admixed with Nitobond SBR Latex at the dosage of 3 L/bag of cement under.(d) Cracks Treatment: Chasing the cracks and cut open the same in V Groove and Cleaning the same with Air blower & with water then it shall fill with Nitoseal PU 50 Sealant/ Conbextra GP2/ Conbextra EP10 Low viscous Grout or equivalent as per the substrate condition.(e) Injection Grouting (wherever required): Pressure grouting shall be done with Cebex 100 or equivalent plasticizing expandable cementitious grout admixture. The material shall be injected using 40 PSI injection grout pump with cement slurry mixed Cebex 100 at 225 gms per 50 Kg bag of cement.(f) Bore Packing/ Pipe Outlets: Preparing the inside surface of core and PVC by roughening using suitable file to get better adhesion prior to packing works. Packing the gap using non-shrink cement polymer-based grout using Conbextra GP2 or equivalent up to the surface of the bore whilst the Nitobond SBR is in tacky state. |
| 73 | (g) Water Proofing System: Providing and applying single component pitch free polyurethane based coating of fosroc make Fosroc Nitoproof 600 PF or equivalent that cures by reaction with atmospheric moisture to form a tough but flexible waterproof membrane. The waterproof coating shall be elastomeric, seamless waterproof membrance applied in 2 coats @ 2 Kg / Sqm to formDFT of 1.2mm thick applied over the prepared surface that is coated with Fosroc Nitoproof WB Primer: The Polyurethane waterproof coating shall have the following properties:1) Elongation (ASTM D412) > 400%2) Tensile Strength – (ASTM D412) – 2.5 N/mm23) Adhesion in-peel test – (ASTM C836) - >50N4) Recovery from Elongation (ASTM D412) – 95%5) Crack bridging as per C836 – 95- >2mm6) Water permeability @ 5 bar, (BSEN 12390) – Nil.(h) Supplying and application of Geotextile of 120 GSM of approved make over the coated area for protection and separation Layer.Note:- (i) Water proofing treatment shall carry a warranty of 05 (Five) years from the date of completion of the contract and issue of completion certificate. Final payment of this item shall be released on production BGB / FDR of equivalent value valid for a period of 05 years from the date of completion. (ii) The rates quoted are inclusive of removal of existing tarfelt treatment and removing to 50 m distance. |
| 74 | Grading roof for water proofing treatment with Cement Concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size. |
| 75 | Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint ofany colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work 75 mm/100 mm diameter pipe metre |
| 76 | Providing and fixing 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 77 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 78 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post fushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 79 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 80 | W.C. pan with ISI marked white solid plastic seat and lid |
| 81 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge |
| 82 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 83 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than300 gms. |
| 84 | Providing and fixing toilet paper holder : |
| 85 | C.P. brass |
| 86 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 87 | 32 mm dia |
| 88 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 89 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 90 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 91 | 15 mm nominal bore with 45 cm length |
| 92 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank |
| 93 | Providing and fixing ball valve(brass) of approved quality High or Low pressure with plastic floats complete |
| 94 | 20mm nominal bore |
| 95 | 25mm nominal bore |
| 96 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms |
| 97 | 15 mm nominal bore |
| 98 | Providing and fixing G.I Pipes complete with G.I fittings and clamps i/c making good the walls etc concealed pipe including painting with anti corrosive bitumastic paint, cutting the chases and making good the wall |
| 99 | a)15mm dia nominal bore |
| 100 | b)20mm dia nominal bore |
| 101 | Providing and fixing Gun Metal Gate valve with CI wheel of approved quality |
| 102 | a)25mm nominal bore |
| 103 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 104 | 15 mm nominal bore |
| 105 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 106 | 150 mm dia. R.C.C. pipe |
| 107 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. |
| 108 | With stainless steel cover plate minimum 1.25 mm thickness |
| 109 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge. |
| 110 | Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardent having necessary screw holding capacity. Shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. |
| 111 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface all as directed by Engineer-in-charge. |
| 112 | Additional Work |
| 113 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 114 | All kinds of soil. |
| 115 | Providing and laying cement concrete 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 116 | Centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 117 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 118 | Foundations, footings, bases of columns, etc. for mass concrete |
| 119 | Providing and laying cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 120 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and Stone aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per S: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. |
| 121 | All works upto plinth level |
| 122 | Concrete of M-25 grade with minimum cement content of 330 kg /cum |
| 123 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 124 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 125 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 126 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 127 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 128 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 129 | cement mortar 1:4 (1 cement : 4 coarse sand) |
| 130 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 131 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 132 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 133 | Hot finished welded type tubes |
| 134 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 135 | Providing and fixing factory made UPVC glazed /wire mesh window/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for series R1 and R2 profiles and 2.10 mm for series R3 and R4 profiles conforming to EN : 12608 in any shape, colour and design duly reinforced with galvanised mild steel section made of required shape & size as per CPWD specification, uPVC extruded glazing beads, interlocks and inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profiles of frames, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc, After fixing frame the gap between frames and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh/ Glazing of plain/toughmed/laminated/doluble glass unit with/without high performance coatings as per design requirements and conforming to IS : 3548 & IS :16231 shall be paid separately. |
| 136 | Three track three panels sliding window with Two nos. glazed & one no. wire mesh panels with Aluminium Channel for roller track, wool pile, nylon roller with SS 304 body. Using R4 series with frames (115 mm & above ) x ( 45 mm & above) & both glazed and fly screen sash ( 44 mm & above) x ( 55 mm & above) with zinc alloy (Zamak) powder coated handles on every glazed pannel along with multi-point locking system. |
| 137 | Chequerred precast cement concrete tiles heavy duty 22 mm thick in vehicular traffice zones, drive ways, parking zones & court yards , jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) as approved & directed by Engineer-in-charge. |
| 138 | Light shade pigment using white cement |
| 139 | Dismantling work: |
| 140 | Dismantling W.C. Pan of all sizes all types including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. |
| 141 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 142 | Dismantling tile work in floors and roofs laid in cement mortar including stackling material within 50 metres lead |
| 143 | for thickness of tiles 10 mm to 25 mm |
| 144 | Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : |
| 145 | Bituminous road |
| 146 | Dismantling partition walls of wood/ particule board/ hard board / work stations consisting of tables , drawers et c of any description carefully and storing at a place shown, and refixing in the same place after completion of flooring, repairs to walls, doors, window and ceilings etc. Cost of refixing including all accessories(clamps, fasteners, bolts, nuts, rubber buses, studs washers, foot rests etc), required are included in this item all as directed by Engineer-in-charge :(Note :-Only vertical surfaces will be measured for payment purpose) |
| 147 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 148 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead |
| 149 | of Area 3 Sqm and below |
| 150 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 151 | G S Sheet |
| 152 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 153 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 154 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 155 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 156 | In Cement Mortar |
| 157 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 158 | Nominal concrete 1:4:8 or richer mix (including design mix or any grade ) |
| 159 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
| 160 | 15 mm to 40 mm nominal bore |
| 161 | Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead |
| 162 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 163 | In Cement Mortar |
| 164 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, lling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost) |
| 165 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in- charge. |
| 166 | Internal Electrification |
| 167 | Rewiring for light point/fan point/exhaust point/call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessesed steel/PVC conduit including dismantling as required. |
| 168 | Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recesses including cutting the wall and making good the same in case of recessesed conduit as required. |
| 169 | (a) 20 mm |
| 170 | (b) 25 mm |
| 171 | (c) 32 mm |
| 172 | (d) 40 mm |
| 173 | Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI Box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required including dismantling as required. |
| 174 | (a) One light point. |
| 175 | (b) One ceiling fan point. |
| 176 | (c) One Exhaust fan point. |
| 177 | (c) One call bell point. |
| 178 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connection etc. as required. |
| 179 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. as required. |
| 180 | Supplying and fixing call bell/buzzer suitable for single phase, 230 volts complete as required. |
| 181 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleev of suitable size on 5the floor/wall, or side of the table,/ door etc. as required. |
| 182 | Installation, testing and commissioning of ceilling fan, including wiring the down rods of standard length (upto 30 cm ) with 1.5 sqmm FRLS PVC insulates, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 183 | Numbering of of ceiling fan / exhaust fan / flurescent fittings as required. |
| 184 | Supplying and fixing two module stepped type electronic fan regulator on the existing module plate switch box including connection but excluding modular plate etc., as required. |
| 185 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface /recessed medium class PVC conduit as required. (NOTE - Colour code shall be maintain as per IE rule for all schedule items and including resistance test, wiring diagram and inventory shall be made after completion,complete all as specified and as directed. |
| 186 | (a) 2 runs x 1.5 Sqmm and 1 x 1.5 Sqmm earth wire (For Socket/light Circuit) |
| 187 | (b) 2 runs x 2.5 Sqmm and 1 x 2.5 Sqmm earth wire (For Socket/light Circuit) |
| 188 | (c) 2runs of 4 Sq.mm wires with 1run of 4 Sq.mm wire in and including 25mm dia PVC Conduit (For Power Sockets). |
| 189 | (d) 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wire in and including 25mm dia PVC Conduit. (For AC Sockets). |
| 190 | (e) 4 runs of 6 Sq.mm wires with 2 runs of 6 Sq.mm wires in and including 32 mm Dia PVC Conduit (For Lighting Sub Mains) |
| 191 | (f) 4 runs of 10 Sq.mm wires with 2 runs of 6 Sq.mm wire in and including 32 mm Dia PVC Conduit (For Power Sub Mains) |
| 192 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required for the following size. |
| 193 | (a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 194 | Supply of Exhaust fan of 300 mm sweep with Metalic blades and MS gravity louvers including all accessories / Installation materials required. |
| 195 | Installation of Exhaust fan in the existing opening including making good the damage connectionj testing commissioning etc. As required upto 450 mm sweep. |
| 196 | Supply, Installation, Testing and commissioning for Water heater Geyser 25 Litre capacity storage type operating on single phase Ac supply 330 Volt 50Hz power supply and including high capacity steel wire mesh Pipe suitable size with washers and nuts, fixinf on wall/ surface including necessary connection, complete all as spoecified and as directed. |
| 197 | Supplying and fixing following size / module G.I box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 198 | (a) 2 Module (75 MM x 75MM) |
| 199 | (b) 3 Module (100 MM x 75MM) |
| 200 | (c) 6 Module (200 MM x 75MM) |
| 201 | (d) 8 Module (125 MM x 125MM) |
| 202 | (e) 12 Module (200 MM x 150MM) |
| 203 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connection but excluding modular plate etc. As required. |
| 204 | (a) 5/6 Amp Switch |
| 205 | (b) 15/16 Amp Switch |
| 206 | (c) 3 Pin 5/6 A socket outlet |
| 207 | (c) 3 Pin 15/16 A socket outlet |
| 208 | (d) Telephone socket outlet |
| 209 | (e) TV antenna socket outlet |
| 210 | (f) Bell Push |
| 211 | Supplying and fixing 20 A, 240 Volts, SPN Industrial type socket outlet, with 2 pole, and earth , metal enclosed plug and top alongwith 20A \\"C\\" curve, SP, MCB, in sheety vstewel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. |
| 212 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 213 | Supply andf fixing LED light fixtures on wall/ Ceiling including all fixing accesssories, complete as required. The fixtures shall be complete with all prewired upto the terminal block. All fixtures shall be supplied with lamps. The Catalogue Numbers refers to Philips Make, complete all as specified and as directed. |
| 214 | (a) 43W LED luminaire 4ft LED Luminaire with high transmitive diffuser suitable for indoor spaces fully diffused recessesed mounting light fitting as per site requirement.(Make Philips cat part No- RC 380B LED43S-6500 G5 L3W12 PSU OD) or equivalent approved make,comnplete all as specified and as directed. |
| 215 | (b) 40W LED luminaire 4 feet light fitting essential smart bright light weight and screw less linear batten with high efficiency for modern commercial appications, comprising of extruded aluminium housing superior finish, long life and high transivity polycarbonated diffuser high efficiency and uniform lighting fitting as per site requirement.(Make- Philips Cart Part No- BN170C LED40S-6500 PSU L120) or equivalent approved make,comnplete all as specified and as directed. |
| 216 | (c) 20 W LED light fitting slim profile surface mounted down light with options of 700 to 2000 lumens in round or square as required as per site requirement. (Make Philips Cat Part No- SM250C LED 75- 6500 PSU WH) or equivalent approved make. |
| 217 | (d) 20 W LED light fitting slim profile surface mounted down light with options of 700 to 2000 lumens in round or square as required as per site requirement. (Make Philips Cat Part No- SM251C LED 20S- 6500 PSU WH) or equivalent approved make. |
| 218 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, VTPN distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCCBs (but without MCBs and incomer ) as required. (For UPS Roon) |
| 219 | 4 way (4 + 12), Double door |
| 220 | 8 way (4 + 24), Double door |
| 221 | 12 way (4 + 36), Double door |
| 222 | Supplying and fixing of 6A to 32A rating 240/415V,10kA , C Curve miniature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections, testing and commissioning etc complete. |
| 223 | (a) MCB Single pole |
| 224 | (b) MCB Single pole and neutral |
| 225 | Supplying and fixing following rating four pole (three Phase and neutral), 415 volts, residential current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 226 | (a) 63 A capacity |
| 227 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt complete all as specified and complete all as specified and as directed. |
| 228 | Providing and laying earth connection with 6 SWG dia G.I Wire in 15 mm dia G.I pipe from earth electrode including connection with G.I thimble excavation and re-filling as required. |
| 229 | Supplying and drawing 2 pair 0.5 sqmm dia FRLS PVC insulated annealed copper conductor, unarmoureed telephone cable in the existing surface / recessesed steel/PVC conduit as required. |
| 230 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closedcellelastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, Contd ... |
| 231 | Contd... wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Contd ... |
| 232 | Contd... Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only With inbuilt stabilizer.. Contd ... |
| 233 | (a) 2 TR with 5 Star BEE Rating (with inbuilt stabilizer) |
| 234 | (b) 1.5 TR with 5 Star BEE Rating (with inbuilt stabilizer) |
| 235 | Supply, Fabrication of 1set MS bracket suitable for fixing out door unit of split AC unit. |
| 236 | COOPER REFRIGERANT PIPING Soft/hard drawn copper refrigerant piping, complete with fittings of following capacity. |
| 237 | (a) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 238 | (b) 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 239 | (c) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 240 | (d) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 241 | Supply & fixing 25 mm dia UPVC drain pipe. |
| 242 | External Electrification |
| 243 | Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of 160 KVA , 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load banks for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Turbo charged Diesel engine 4 stroke Air cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 °C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. (B) Engine mounted Instrument Panel fitted with and having digital display for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level Similar to Cummins PCC 3.0 or better. |
| 244 | (C) Alternator: Synchronous alternator rated of appropriate KVA,415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8lagging power factor at 40 Degree C, 50% RH & at 1000 MeterMSL. The alternator shall be having Screen Protected DripProof (SPDP) enclosure IP23, brushless, continuous duty,dynamically balanced rotor, capable of taking 10% overloading for one hour after 12 hours of continuous operation,self cooled,self-excited and self-regulated through AVRconforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable fortropical conditions and with class- H insulation.(D) Base Frame & Foundation: Both the engine and alternatorshall be mounted on suitable base frame made of MS channelwith necessary reinforcement which shall be installed onsuitable cement concrete foundation and vibration isolationarrangement as per recommendations of manufacturer.(E) FUEL TANK :Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.(F) Exhaust System:Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. |
| 245 | (G) Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-54 or better protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications. (I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole / MCCB with electronic release for O/C & E/F and shunt trip in series with suitable sized power Contactor 2. Auto/Manual/Test/Off selector switch 3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5. Energy Manager unit to indicate current, Voltage( L-N & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF. Contd. |
| 246 | 6. LED Indicating lamps for load on mains and load on set.7. Fuse/ MCB for instruments 8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic engine start/ stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date.18. Load Management through PLC to achieve auto operations in case of power failure , interlocking providing signal to AMF Panel forload status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring. |
| 247 | Supply, connection, Testing and commissioning XLPE screened PVC insulated steel strip armoured under ground copper stranded cable 1100 Volts grade, confirming to IS:7098(Part-I) and including making and copper lugs as required for the following size of cross sectional area :- |
| 248 | (a) 120 Sqmm 3.5 Core. |
| 249 | (b) 150 Sqmm 3.5 Core. |
| 250 | (c) 16 Sqmm 4.0 Core. |
| 251 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushouoning, protective covering and refilling the trench etc. as required. |
| 252 | (a) Above 95 sq. mm and upto 185 sq. mm |
| 253 | (a) Upto 35 sq. mm |
| 254 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1100 volts grade of following size direct in existing masonry duct as required. |
| 255 | (a) Above 95 sq. mm and upto 185 sq. mm |
| 256 | (a) Upto 356sq. mm |
| 257 | Supplying and making end termination with brass compression gland and Copper Lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required for the following sizes :- |
| 258 | (a) 120 Sqmm 3 core (45mm). |
| 259 | (b) 150 Sqmm 3 core (50mm). |
| 260 | (c) 16 Sqmm 4 core (28mm). |
| 261 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 262 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (For UPS) |
| 263 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 264 | Supplying and laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 265 | Supply, installation and testing of maintenance free chemical Earthing using copper bonded steel rod 17.2mm dia, 2.4 metres long and using groung enhancing artificial soil treatment chemical compound, TFRFC & Earthcon, having essential chemical ingradients, such as ionic cxhemicals, disperson chemicals, expansion chemicals, diffusion chemicals and hygroscopic chemicals, to provide stable low resistance in the earth terminal to make it maintenance free, (the Earth terminal ahall consist of 3 Nos separate earth pits for each down conductor) as per IEEE 80-2000 14.5D clause, complete all as specified and as directed by Engineer-in-Charge. (For Server) |
| 266 | Providing and laying earth connection with 6 SWG dia G.I Wire in 15 mm dia G.I pipe from earth electrode including connection with G.I thimble excavation and re-filling as required. |
| 267 | Supply and fix for post top lantern LED fitting 50 Watt light (IP65) complete all as specified or as directed.(Philips-BGP300 LED 50 757 PSU PC IN S1) or equivalent,complete all as specified and as directed. |
| 268 | Supply and fix for 9W City cube Bollard garden LED light fitting. Philips model No- BCP400 LED09 D CW PSU GR S1 or equivalent approved make, complete all as specified and as directed. |
| 269 | Junction Box with busbar strip Phase and Neutral |
| 270 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and Stone aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per S: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. |
| 271 | Concrete of M-25 grade with minimum cement content of 330 kg /cum. Above plinth level to Floor V level. |
| 272 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 273 | Suspended floors, roofs, landings, balconies and access platform |
| 274 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 275 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 276 | Providing and laying design mix cement concrete of M-30 grade, in roads/taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. |
| 277 | Cement concrete prepared with batch mixing machine |
| 278 | Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. |
| 279 | Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. (10mm wide & 50 mm deep) |
| 280 | SCHEDULE OF CREDIT |
| 281 | Credit for Steel |
| 282 | Old Wash Hand Basin |
| 283 | Old unserviceable Building/grills/Gates Steel (Iron Scrap). |
| 284 | Wooden shutters of any description |
| 285 | Old EWC |
| 286 | Old Toilet Paper Holders, Health Faucet |
| 287 | Taps of any size |
| 288 | poly storage water tank |
| 289 | PVC Doors |
| 290 | GI Pipes of any dia |
| 291 | Old Brick |
| 292 | unserviceable wiring |
| 293 | unserviceable conduit |
| 294 | Old unserviceable light fittings |
| 295 | Old unserviceable switches |
| 296 | Old unserviceable boxes |
| 297 | Old unserviceable sockets any type |
| 298 | Old unserviceable Post top lantern fitting |
| 299 | Old unserviceable Road Bollard light |
| 300 | Old unserviceable UG cable 16 Sqm 4 core |
| 301 | Old unserviceable Sub main wiring any type Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysJul 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender