| 1 | Fabrication, supplying, installing, testing and commissioning of indoor type free standing weather and vermin proof flush compartmentalized modular, totally enclosed type electrical starter panel for Azadpur (as per general arrangement size not less than 3.5 sq. mtr. and 0.45m deep made out of 2.0mm thick sheet steel with front and back hinged openable double leaf doors with panel lock including supplying and fixing following accessories inside the panel, drilling, welding, providing detachable gland plate / knock outs plate, connections, as required. The cubical board shall be provided with base channel of (ISMV 100 designation) of size 50*50mm including painting the base channel with primer and finish paint, complete as per general arrangement drawing approved by Engineer-in-charge . The LT panel shall generally confirm to CPWD General Specifications for Electrical works, Part-1,Internal 2005, Part-2 External 1994 and Part-4 substation equipment-2007 as amended upto date. The panel shall be installed on a suitable brick pedestal of suitable size in an approved manner.400 A, 50KA FPMCCB = 1 No.6 Amps SP CONTROL MCB = 15 Nos.10 Amps DP CONTROL MCB = 6 Nos.100 A, 36KA TPMCCB = 1 Nos.63 A, 36KA TPMCCB = 4 Nos.Spreader Terminal 4 Pole = 1 No.Spreader Terminal 3 Pole = 5 Nos.Direct ROM = 5 Nos.R-Y-B Indication Lamp = 13 Nos.VAF+PF METER = 6 Nos.CT COIL 50/5 = 15 Nos.CT COIL 400/5 = 3 Nos.PUSH BUTTON WITH ELIMENT = 10 Nos.230/24V, DC 8.2A SMPS = 1 No.4 CHANNEL RELAY CARD = 1 No.AUTO/MANUAL SELECTER SWITCH = 5 Nos.50 HP VFD= 1 Nos.30 HP VFD= 4 Nos.4\\" Cooling Fan = 5 Nos.6\\" Cooling Fan = 1 No.400 A Changeover = 1 No.Tablet= 1 Nos. |
| 2 | Fabrication, supplying, installing, testing and commissioning of indoor type free standing weather and vermin proof flush compartmentalized modular, totally enclosed type electrical starter panel (as per general arrangement size not less than 4.8 sq. mtr. and 0.45m deep made out of 2.0mm thick sheet steel with front and back hinged openable double leaf doors with panel lock including supplying and fixing following accessories inside the panel, drilling, welding, providing detachable gland plate / knock outs plate, connections, as required. The cubical board shall be provided with base channel of (ISMV 100 designation) of size 50*50mm including painting the base channel with primer and finish paint, complete as per general arrangement drawing approved by Engineer-in-charge . The LT panel shall generally confirm to CPWD General Specifications for Electrical works, Part-1,Internal 2005, Part-2 External 1994 and Part-4 substation equipment-2007 as amended upto date. The panel shall be installed on a suitable brick pedestal of suitable size in an approved manner.320 A, 50KA FPMCCB = 1 No.100 A, 36KA FPMCCB = 2 No.6 Amps SP CONTROL MCB = 18 Nos.10 Amps DP CONTROL MCB = 6 Nos.63 A, 36KA TPMCCB = 3 Nos.Spreader Terminal 4 Pole = 1 No.Spreader Terminal 3 Pole = 5 Nos.Direct ROM = 5 Nos.R-Y-B Indication Lamp = 13 Nos.VAF+PF METER = 6 Nos.CT COIL 50/5 = 15 Nos.CT COIL 300/5 = 3 Nos.PUSH BUTTON WITH ELIMENT = 10 Nos.230/24V, DC 8.2A SMPS = 1 No.4 CHANNEL RELAY CARD = 1 No.AUTO/MANUAL SELECTER SWITCH = 5 Nos.30 HP VFD= 2 Nos.30 HP VFD= 3 Nos.4\\" Cooling Fan = 5 Nos.6\\" Cooling Fan = 1 No.320 A Changeover = 1 No.Tablet= 1 Nos |
| 3 | Supplying, installation, testing & Commissioning of ultrasonic sensor in each water storage tank with measuring range upto 5 meters measurement accuracy of 0.5% - 1.0%, Resolution ratio of 3mm or 0.1% (whichever is greater) with LCD digital Display, Analog output of - 4-line system with 4-20mA current, 510 Ù load, 2-line system, 4- 20mA, 250 Ù load with Relay output - 2 group (i.e. AC 250V/8A or DC 30V/5A) with 24VDC supply, Ambient temperature Display instrument - 20~+60°C with IP66 protection etc complete as reqd. |
| 4 | Supplying of Micro Processor Unit having a high-performance 32-bit ARM Cortex-based processor operating up to 72–180 MHz with embedded Flash memory, SRAM, multi-channel 12/16-bit ADC, advanced timers, PWM generation, RTC with battery backup support, watchdog protection, and multiple communication interfaces including UART, SPI, I2C, CAN. The system integrates WiFi SoC supporting IEEE 802.11 b/g/n at 2.4 GHz with built-in TCP/IP stack, WPA/WPA2 encryption, SSL/TLS security, OTA firmware upgrade capability, and dual operating modes (Station/AP). Operating Voltage 9–24V DC input supply with reverse polarity, over-voltage, surge, and short-circuit protection, along with high-efficiency DC-DC regulation for stable 5V and 3.3V rails. Communication is provided through industrial-grade RS485 (Modbus RTU compatible) with configurable baud rate and multi-drop capability. Including heavy-duty electrically isolated relay outputs (NO/NC type) suitable for pump contactor control, along with LED status indication.Including common HMI/Tablet for various setting like pump automation with user-configurable tank level start and stop settings, adjustable hysteresis control, and support for float or sensor-based inputs. The system incorporates automatic pump rotation logic to ensure equal runtime distribution and seamless alternation after each stop cycle. User-configurable priming interval and priming time settings allow efficient air removal and smooth pump startup. Advanced under-current monitoring enables dry-run detection with adjustable threshold settings and automatic pump trip protection. The controller also includes user-defined maximum pump run time protection to prevent overheating or mechanical damage.SCADA compatibility via Modbus RTU/TCP, and remote monitoring capability through WiFi connectivity |
| 5 | Supply & installation of Scada software for online Monitoring pump house of site with following specification:-Overview: The SCADA software shall provide comprehensive real-time monitoring, control, and data management for the water distribution system. It will enable users to remotely view and manage the system from anywhere using web browser.SCADA Software with Server Validity of 3 Years Key Features:Real-Time Data Monitoring: Displays real-time status and parameters of all system components, including pumps, sensors,flow meters and valves.User Interface (UI): A user-friendly, customizable live UI that shows the current status of all system components.The UI shall provide basic functions for supervision and control of the system.The UI shall give the user access to alarms and events displayed on the screen. Aside from these lists on the screen, there shall be a printout of alarms or events in an event log.The following standard pictures shall be available from the UI.➢ Graphical diagram showing the Hardware status.➢ Pop us box to display pump details like voltage, ampere, Power Factor, Power consumption etc.➢ Event list, station➢ System status.Remote Command Execution: Enables users to issue remote commands for controlling pumps, sensors and valves. In order to ensure a high degree of security against undesired operation, a “select-before-execute” command procedure shall be provided. After the “selection” of a hardware, the operator shall be able to recognize the selected device on the screen and all other hardware shall be blocked. As communication between control centre and device to be controlled is established, the operator shall be prompted to confirm the control action and only then final execute command shall be accepted. After command execution the user shall receive a confirmation that the command is executed. In theselected object picture, all attributes like➢ Authority➢ Local / remote control➢ Errors etc. shall be displayed.Event Data Management: Allows users to download and analyse historical event data logs.The Report page shall contain all the commands that are executed for the control and monitoring of the water distribution system.The event and associated time of its occurrence has to be displayed for each event. The event page shall be automatically updating at real time within maximum of 10sec duration.The operator shall be able to call up the event list on the monitor at any time for the whole water distribution system or sections of it. The events shall be registered in a chronological event list in which the type of event and its time of occurrence are specified. It shall be possible to store all events in the computer for at least one year. The Report page shall be download in pdf and excel format. The Report can be viewed/download in web browser by selection of date and time in From and to format between 1-year period.The chronological event list shall contain:➢ All Hardware of system like - pumps, sensor, valve.➢ All Pumps parameter like Voltage, Current, Power Factor, Power consumption etc installed in thesystem.➢ All sensor values installed in the system.➢. All Valve status installed in the system.➢ Loss of communication.➢ Filters for selection of a certain type or group of events shall be available. The filters shall be designedto enable viewing of events grouped per:➢ Date and time.➢ Hardware➢ Status |
| 6 | Providing & Fixing of WiFi router for monitoring of pumps with the following specifications:-External Power Supply: 9VDC/0.6AInterface:-4 10/100Mbps LAN Ports: 1 10/100 Mbps WAN PortsDimension: 7.6 x 5.3 x 1.3 in. (193 x 134 x 33mm)Antenna: 2.5dBi Fixed Omni Directional AntennaWireless Function: Enable/Disable Wireless Radio, WDS Bridge, WMMWireless security: 64/128/ 152-bit WEP/ WPA/ WPA2,WPA-PSK/WPA2-PSKFreequency: 2.4-2.4835GHz |
| 7 | Supplying and drawing of following size FR PVC insulated single core & multi core sheathed/unsheathed industrial flexible copper conductor cable of 1100V grade complete as required.4 x 1 sq. mm |
| 8 | 6 x 1 sq. mm |
| 9 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia |
| 10 | 150 mm dia |
| 11 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia |
| 12 | 150 mm dia |
| 13 | Supplying, laying and fixing of following size PVC insulated and PVC sheathed/ XLPE aluminum conductor armoured power cable of 1.1 KV grade on wall/surface etc. as required.3.5 x 25 sq. mm |
| 14 | 3.5 x 50 sq.mm |
| 15 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required |
| 16 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 17 | Supplying, installing, testing and commissioning of 5 HP submersible pump with CI body, CI impeller and CI shaft capable to deliver of following capacity and head given by IE2 squirrels induction motor suitable for operation on 3 phase, 400 volt , 50 HZ AC power supply with all necessary protection and seal and other accessories.Flow rate : 1400 LPM @ Head 8 mtr. |
| 18 | Providing, Installing, Testing & Commissioning of Storm Water SCADA Software Integration with existing centralized PWD headquaters, including supply and configuration of SCADA server, workstation, communication gateways, industrial networking equipment, VPN and firewall setup, creation of centralized SCADA database, tag mapping of field instruments, microprocessor communication programming through Modbus TCP/IP, OPC and Ethernet protocols, development of graphical HMI mimic screens, real-time data acquisition, alarm and event management, historical data logging, trend analysis, report generation, remote operation and control of pumps, motorized valves and field devices, integration of level sensors, flow meters, and electrical parameters, configuration of user access levels, cybersecurity implementation, redundancy and backup setup, server commissioning, communication testing, FAT/SAT, system validation, operator training and all associated hardware, software, engineering services, cabling and accessories required for complete centralized monitoring and control of the Storm Water System from MSO Building Headquarters. |
| 19 | Providing & installation of Butterfly Valve/ ball valve with electrical actuated (upto 80mm) a self-contained control package with local controls, status indication relays, isolated control circuits with 24 VDC, 220 VAC, 1Ø, 50Hz, position indication via local manual indicator, temperature rating from - 5 ْْC to +50 operation and etc. as required with following facility. AIL SLIMSEAL is a Wafer type Butterfly Valve with an integrally moulded elastomer body liner with working pressure rating upto 10NM. Specification for Butterfly valves/ ball valves, Wafer Short API 609 - Lug and Wafer type Butterfly Valves, Category A MSS SP 67 - Butterfly valves, Narrow body ISO 5752 - used in flanged pipe systems, Face to face and Centre to face dimensions. BS 6755 Part 1 Pressure testing Black Nitrile/EPDM seat Test Pressure is at Body / Disc 24 & Seat 17.6. Potentiometer unit is synchronous with output transmission shaft to provide a feedback signal. Local control unit is control with local/Remote selection switches. Position Indicator can be either 0-100% or 4-20mA. Programmable Logic control. Electrically & Mechanically Interlock Run the actuator for a per defined travel in ON-OFF step. |
| 20 | Supplying, Installing, Testing and Commissioning of Mechanical Multirake Coarse Bar Screen with microprocessor based control panel, remote monitoring & operation system, electrical works, accessories and allied works as required.The screen shall be fabricated entirely in Stainless Steel SS-304 and shall consist of a series of vertical flat bars with automatic mechanical cleaning arrangement.The equipment shall comprise of the following minimum specifications:Type : Mechanical Coarse Bar ScreenBar Spacing : 25 mmMaterial of Construction : SS-304Drive Motor : 2 HP suitable for continuous duty operationScreen Size : Not less than 1300 mm x 3000 mmBar Size : 6 mm x 40 mmScreen Frame Thickness : 4 mmAngle of Inclination : 70 DegreeChain, Chain Sprocket, Motor Cover and Chain Cover : SS-304Complete mechanical cleaning arrangement with chain driven mechanismNecessary guide arrangement, supports, fasteners, anchor bolts and structural members.The item shall also include:VFD based starter/control panel suitable for operation of the bar screen including soft starting, overload protection, dry run protection, phase failure protection and auto/manual operation.Remote monitoring and controlling system including provision for remote start/stop, running status, fault indication and operational monitoring.Local push buttons, selector switches, indication lamps, emergency stop arrangement and interlocking features complete.Necessary power and control cabling from panel to equipment including cable glands, lugs, trays and termination.Plastic Dustbin with LID and Tyres - 2 Qty , Capacity - 1100 Ltr. |
| 21 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 22 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 23 | SH2 :- AMC of Storm Water Management System1st Year (Defect Liability Period) |
| 24 | 2nd Year |
| 25 | 3rd Year Please Enable Macros to View BoQ information |