| 1 | Supplying, installation of Pump House Automation Control & Electrical Panel ,Outdoor cubical Panel duly powder coated having suitable The panel has to be fabricated from 1.6 mm thick CRCA sheet duly compartmentalized suitable for Panel Stand 415volt 50Hz A.C supply of size not less thanwith control and power wiring & Suitable for Having Wiring channel, MCB, Relay card channel, Terminal Block, Panel Control Wiring & Panel Stand complete in all respect etc.(Make:- BCH, Verilii, System & Renewable Control, GIC )I) Cooling fan 4\\" 1 no. (Make- Rexroth/Jigo)II ) SPMCB 6-32 Amp. 2 no. (Make- BCH/L&T/schneider/HPL )III) 32 Amp TPN 1 no. (Make- (Make- BCH/L&T/schneider/HPL ) IV ) Relay card 8 Channel (Make- Omron/ L&T/Selco/HPL)V ) Push Button Flush Head 8 no. (Make- BCH/L&T/schneider/HPL )VI) Contact Blocks 8 no. (Make- BCH/L&T/schneider/HPL ) VII) Push Button & Selector Actuators 8 no. (Make- BCH/L&T/schneider/HPL)VIII) SMPS 24 VDC 2.5 Amp. 1 no.(Make - Delta /Omron/GIC)IX ) Indicator Gen Next LED 22.5 mm 8 no. (Make- BCH/L&T/schneider/HPL) |
| 2 | Supplying installation testing & commissioning of MMU (Master Microprocessor Unit) for all wireless device communication & cloud communication with wireless connectivity, Current transformer to be installed in pump house with following accessories listed below: Micro Processor Unit shall have control, protection & live data devices up to I/O 14 Microprocessor Fast Fourier transformation to eliminate harmonics &, Surges True RMS measurements & simultaneous sampling of Volts, Amps 2 layer protection, multiple technologies high performance & accuracy with real time clock wireless connectivity compatible, data backup, various functions high Speed mode with instant switches from one input to the other & can be controlled in slot for memory with connoted to external devices like android/ios/windows platform & PC through software key - CGPS plug - in software. Software key should comprise of UDP/ FTP/HTTP open standard Internal Expansion Wireless CPUR: with an core ARM7 32- bit floating point (72 MIZ max) microprocessor, with integrated IDE & GPRS connection with Uptime - Minimum 95%, Download Speed up to -4 Mbps Transfer unlimited of all measured parameters/ quantity/ Auto Scrolling Password protected user programmable Parameters Fault Indication at display Access Point etc. - 1 No. |
| 3 | Supplying installation testing & commissioning of Ultrasonic Sensor Or Level Sensor status of water tank approx. liquid Quantity in tank, Made of ABS housing, detection rang not less than 2 meters etc. complete as required. |
| 4 | Supplying installation testing & commissioning of microprocessor, suitable With Control & wireless connectivity Device transmitter and recciver (To be installed at near By sensor & line pressurc transmitters for Wireless data Range UPTO 1000 meters. Sending Data from upward to downward) for sending status of water tank to Master Microprocessor unit of on real time basis, for sending/receiving data etc. complete as required. |
| 5 | Supplying installation testing & commissioning of Smart Graphical Display Size 7\\" Inbult Software & Graphical View all Water Distribution Systems etc. complete as required. |
| 6 | Supply & installation of One CPU (Make: - Dell / Lenovo / HP ) One LED 43\\" Display (Make: - TATA Croma , Samsung/ Acer /Sony ) with Complete Cloud based SCADA Software (Supervisory Control and Data Acquisition) With wireless connectivity for AUTOMATIZATION of Pump house , water tank level for on line Monitoring pump house , Over Head Tanks & Under Ground Tanks with following specification. Server application for monitoring and controlling of system Data receive and sent through central application, event log store in server and can be checked, different level Message to different installation unit and location Software can be breakup in to different level for checking whole pump house and Tank Levels according to the client needs. Data Recipient should be added or delete manually according to the need as per the office requirement .Online Monitoring application should be within System for tracking. Data storage should be at central server for proper backup and support. Gateway server will manage all the incoming and outgoing Data. Fault or any breakdown reported immediately to concerned person through mobile messaging (persons can be 2 number). Each operations log stored in server & can be checked later on. Software can be breakup in to different level for checking whole pump house according to the client needs. Report can be checked according to the predefined level. Pump House data of different units can be stored in the software and Data will be done according to the employees in the unit. On network failure message should resend the data again. Internet tracking of all the operation in pump house through Web Login etc. complete as required. |
| 7 | Supplying installation testing & commissioning of Microprocessor Device besad online Control and Communication For SCADA , Data for Sensors and pumps GPRS DATA For One Year, True RMS. measurements & simultaneous sampling of Volts, Amps android/os/windows platform & Pc through software key + GPS plug - in software. Software key should comprised of UDP/FTP/HT TP open standard Internal Expansion Wireless CPU@: with an core ARM7 32- bit floating point 72 MHZ, max) microprocessor, with integrated IDE with Uptime - Minimum 95%, Download Speed up to - 4 Mbps Transter unimited of all measured parameters/quantity/ Auto Scrolling Password protected user programmable Parameters Fault Indication at display Access Point etc. complete as required. |
| 8 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 4 x 1.5 sq. mm |
| 9 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25mm Please Enable Macros to View BoQ information |