| 1 | Taking down carefully by disconnecting electrical connection of unserviceable ceiling fans/exhaust fans of any sweep and size from its position at different locations in cantt area and removing the same fan to MES store yard to keep in safe custody for repairing/overhauling and refixing/ reinstallation of repaired/serviceable fans (taken from MES store yard) to the different locations in cantt area complete all as directed by Engineer-in-charge. Note : Transportation of ceiling fans/exhaust fans from site location to MES store yard & back shall be made through proper issue/receipt voucher duly mentioning by MES rep. |
| 2 | Servicing ceiling fans of 1200mm/1400mm/ any sweep and size for repairing/overhauling by cleaning/greasing/oiling etc. and reassembling the same after and including replacement of unserviceable spare parts as required. (which shall be measured and paid separately under respective items here-in-after) complete all as specified and as directed by Engineer-in-charge. |
| 3 | Supply only ball bearing SKF 6202/6201/equivalent suitable for 1200/1400 mm sweep ceiling fans complete all as specified and as directed. |
| 4 | Supply only Gun Metal bush suitable for 1200/1400 mm sweep ceiling fans complete all as specified and as directed. |
| 5 | All as per item No 2 here-in-before but for exhaust fans of 450/300/225 sweep and size complete all as specified and as directed. |
| 6 | M&L for cutting of existing winding of ceiling fans of 1200 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of ceiling fans shall only be done in presence of Engineer-in-charge/concerned ground executive. |
| 7 | All as per item No 6 here-in-before but for cutting of existing winding of ceiling fans of 1400 mm sweep complete all as specified and directed. |
| 8 | M&L for cutting of existing winding of exhaust fans of 450 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-charge. |
| 9 | All as per item No 8 here-in-before but for cutting of existing winding of exhaust fans of 300/250 mm sweep complete all as specified and directed. |
| 10 | Supply & fix in repair 2.5 mfd capacitor suitable for ceiling fans of 1200/1400 mm sweep of approved make complete all as specified and as directed. |
| 11 | Supply & fix in repair 4/6 mfd capacitor suitable for exhaust fans of 300 to 450 mm sweep of approved make complete all as specified and as directed. |
| 12 | Supply & fix in repair mild steel clamps with rubber seal, nut bolts with washer and including spliting pin suitable for 1200/1400 mm sweep ceiling fans complete all as specified and as directed.. |
| 13 | Supply & fix in repair down rod fabricated out of 15mm dia heavy grade MS conduit not less than length of 550 mm with suitable fan clamps duly painted with two coat of synthetic enamel White paint complete all as specified and as directed.. |
| 14 | Supply & fix in repair down rod fabricated out of 15mm dia heavy grade MS conduit not less than length of 1250 mm with suitable fan clamps duly painted with two coat of synthetic enamel White paint complete all as specified and as directed. |
| 15 | Supply & fix in repair MS hooks fabricated out of 50x6mm including nut, bolts (6-8 mm dia & 40 to 50 mm long with spring washer) complete all as specified and as directed. by Engineer-in-charge |
| 16 | Supply & fix in repair PVC flexible wire of size 23/.0076 sqmm or 0.50 sqmm multi stranded, twin core, PVC sheathed copper conductor complete all as specified and as directed. |
| 17 | M&L for preparation of old rusted surface of ceiling fans of any sweep by cleaning to remove only dust etc. and applying one coats of synthetic enamel white paint complete all as specified and as directed by Engineer-in-charge. |
| 18 | M&L for preparation of old rusted surface of exhaust fans of any sweep by cleaning to remove only dust etc. and applying two coats of synthetic enamel brown paint and marking MES number with non erasable marker pen with black colour complete all as specified and as directed. by Engineer-in-charge. |
| 19 | Supply and fix in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed. |
| 20 | S&F louvers in repair for Exhaust Fan of size 250mm to 450mm Sweep steel suitable for existing shape and size including taking down existing unserviceable /rusted louvers Complete all as specified and as directed by Engineer In Charge |
| 21 | Supply & fix in repair blade set suitable for ceiling fan 1200/1400 mm sweep of any make as per site requirement all as specified and as directed. |
| 22 | Supply & fix in repair metal blades set suitable for exhaust fan 300/450mm sweep any make as per site requirement all as specified and as directed. |
| 23 | Supply & fix in repair pvc blades set suitable for exhaust fan 300/450mm sweep any make as per site requirement all as specified and as directed. |
| 24 | S&Fin repair for metal Fan Blades of best quality suitable for Desert Cooler of any Make and size including taking out/ down unserviceable one, complete all as specified and as directed. |
| 25 | S&F in repair for PVC Fan Blades of best quality suitable for Desert Cooler of any Make and size including taking out/ down unserviceable one, complete all as specified and as directed. |
| 26 | S&F in repair for Front Grill Double Partition type of 20 SWG metal grill, best quality (as approved) of suitable size for Desert Cooler providing making Electric Connection to all Accessories as required including taking out/ down unserviceable one, complete all as specified and as directed. |
| 27 | S&F for Motor suitable 1/7 HP, 180 Watt, 3 Speed for Desert Cooler, Copper wounded complete and One Set of Lugs for mounting body including taking out/ down unserviceable one, complete all as specified and as directed. |
| 28 | S&F Plastic PVC Distributor suitable for Desert Cooler heavy duty 15mm with Elbow, Tee, etc. fixed with Bolts, Nut & Washers including taking out/down unserviceable one, complete all as specified and as directed. |
| 29 | S&F Plastic PVC Pipe of 15mm bore suitable for Desert Cooler, heavy duty, ISI mark including taking out/down unserviceable one, complete all as specified and as directed. |
| 30 | S&F Selector Switch suitable for Desert Cooler of any Make and size including taking out/ down unserviceable one, complete all as specified and as directed. |
| 31 | S&F Submersible Water Pump suitable for Desert Cooler including taking out/ down unserviceable one, complete all as specified and as directed. |
| 32 | S&F Plug Top, 3 Pin, 5/6 Amp including taking out/ down unserviceable one, complete all as specified and as directed. |
| 33 | M&L for Mild Steel Desert Cooler Body of 20 SWG Powder Coated with 03 Nos Side Shutters of 22 SWG, size 3 ft x 2 ft x 2ft, Noise Pollution Control complete Body including taking out/ down unserviceable one, complete all as specified and as directed. Note:If size is not available, then next higher size shall be brought by contractor at no extra cost to department. |
| 34 | Supply and fix in replacement Angle iron stand size 30x30x3mm with 25 mm cross support between angle frame and both side of front and back stand legsfor desert cooler with rooler Applying one coat of synthetic enamel paint complete all as specified and directed. |
| 35 | S&F Grass Wool Pad (as approved) suitable for Desert Cooler, heavy duty and best quality including taking out/ down unserviceable one, complete all as specified and as directed. |
| 36 | M&L preparing old surfaces of Desert Cooler Body by descaling, rubbing, brushing, cleaning and applying two coats of Synthetic Enamel Paint (as approved) with Spray Gun Machine and Tank with Black Bituminous Paint from Inside Tank, complete all as specified and as directed. |
| 37 | Supply and fix in replacement of wiring kit for BLDC fan suitable for existing make as per site requirment and as per direction of Eng-In Charge complete all as specified and directed. Please Enable Macros to View BoQ information |