| 1 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft / loose soil complete all as specified and directed. |
| 2 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 3 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point completeall as specified and directed. |
| 4 | M & L for precast RCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in cover slabs and the like including providing necessary form work etc, set in cement mortar (1:4) incl. demolition of reiforced cement concrete and disposal out of MOD land complete all as specified and directed (Note : Reinforcement to be measured and paid separately). |
| 5 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 6 | Mild steel TMT bars 10 mm dia and over as in reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 7 | M&L for Brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 incl. demolition of brick work complete all as specified and directed. |
| 8 | M&L for Brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 (Except brick ) incl. demolition of brick work complete all as specified and directed. |
| 9 | Taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 10 | M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces on wall, other than finished even and smooth without using extra cement complete all as specified and directed |
| 11 | M&L for PCC 1:5:10 type E-2 using 40 mm graded brick aggregate for filling up sunken floor over and all around felt of floor complete and incl. demolition of reiforced cement concrete and disposal out of MOD land complete all as specified and directed. |
| 12 | S&F in repair vitreous china squatting pan, ‘Orissa’ pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe,CI trap 100 mm Bore of pipe etc complete all as specified and directed. |
| 13 | S&F in repairs vitreous china wash down water closet (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), fixing seat cover including connection to drain (or outgoing pipe, and to flushing pipe & antisyphonage pipe etc with aluminium hinging device complete all as specified and directed. Note : Plastic seat cover shall be measured separately as Supply only as considered under respective items. |
| 14 | S&F in repair 10 litre capacity PVC low level cistern ‘ white’ with inlet float valve including bracket with 32mm dia PVC pipe 600 mm long complete all as specified and directed. |
| 15 | Supply only plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or Aluminised hinging device complete all as specified and directed. |
| 16 | Cleaning of Chocked sewer line of 100 mm dia any depth through manually or through mechanical appliances and making sewer line functional, complete including working under foul conditions and deposting the sludge rubbish etc off the premises at an isolated places not exceeding 5Km distance complete all as specified and directed Note :- Manholes connected with effected sewer line shall be measured separately. |
| 17 | Cleaning of Chocked sewer line of 150 mm dia any depth through manually or through mechanical appliances and making sewer line functional, complete including working under foul conditions and deposting the sludge rubbish etc off the premises at an isolated places not exceeding 5Km distance complete all as specified and directed |
| 18 | Cleaning of Chocked sewer line of 200 mm dia any depth through diesel running vehicle mounting hydraulic operated high pressure suction-cum-jetting sewer cleaning machine fitted with pump having suction capacity and water jetting tank including skilled operator, supervisor/engineer and two safaiwala etc including working under foul conditions and deposting the sludge rubbish etc off the premises at an isolated places not exceeding 5Km distance all as specified and directed |
| 19 | Desluding/dewatering/cleaning of existing of manhole of any depth by any means ie mechanically or manually operated by taking out off sludge or solid waste night soil (silt) in any proportion and silted soil from the existing manhole of any size and including working under foul condition and depositing the removed sludge rubbish etc from the premises complete all as specified and directed NOTE :- Sludge or soil night waste soil (silt) will be disposed of the area out of premises of MOD and covered the same by bleaching powder @ 1.5 Kg/Sqm over surface of night soil or sludge. |
| 20 | Cleaning of chocked water closet/WC/Floor trap/Gully trap etc manually by taking of sludge waste, night soil and silted soil from the existing pipe, by taking out accumulated garbage, silt, mud etc and removing the same at a distance not exceeding 50 metre (where directed), washing and well flushing of the floor trap/WC/gully trap with water complete as directed by the Engineer-in-Charge.NOTE : (i) Contractor's supervisor will report on all working days along with four safai wala at 0830 hrs at B/R maintainance cell to receive complaint for blockage and to submit complition report on same day by 1700 hrs.(ii) Printed complaint slip Area wise as per format approved by Engineer-in-Charge shall be provided and maintained by contractor. Cost for the same shall deemed inclusive in the quited rate.(iii) Rate quoted above shall be deemed to incl the cost of adequate T&P, equipment, safety device etc alongwith sufficient labour to full fill the requirement to the entire satifaction of Engr-in-Charge. Any despute related to above shall be resolved by Garrison Engineer and his decesion shall be final, binding and conclusive.(iv) If there is any major blockage in sewer line for which additional Safaiwalas and special T&P is required same shall be provided by contractor without any extra cost to Govt there fore contractor is advice to visit the site before quoting the rate in tender.(v) All sewage blokage complaint must be attended within 24 hrs. any sewage blokage complaint is not clear within 24hr( except and otherwise few major/ Difficult complaint prior intimation/ notice to GE/ Engr In Charge) compensation of Rs.100/- per Day per complaint shall be charged from contractor work done without any prior notice based on Job card i.e. user satisfaction. |
| 21 | M & L for salt glazed stoneware drain pipes 200 mm bore, grade 'A' laid in trenches and jointed in cement mortar 1:1 and incl. demolition and breaking up SGSW drain pipes set in cement mortar complete all as specified and directed.Note : Excavation, earth work,salt glazed stoneware drain pipes,concrete bed to drain pipes shall be measured & paid separately under respective items. |
| 22 | M & L for salt glazed stoneware drain pipes 150 mm bore, grade 'A' laid in trenches and jointed in cement mortar 1:1 and incl. demolition and breaking up SGSW drain pipes set in cement mortar complete all as specified and directed.Note : Excavation, earth work,salt glazed stoneware drain pipes,concrete bed to drain pipes shall be measured & paid separately under respective items. |
| 23 | Concrete bed to drain pipes 200 bore including packing under and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C2 using 40mm graded stone aggregate complete all as specified and directed. |
| 24 | Concrete bed to drain pipes 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C2 using 40mm graded stone aggregate complete all as specified and directed. |
| 25 | S&F PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls/floor, 110 mm bore incl. taking down complete all as specified and directed |
| 26 | S&F PVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls/floor, 75 mm bore incl. taking down complete all as specified and directed |
| 27 | S&F in repair 110 mm dia PVC (SWR) bends any radius complete all as specified and directed |
| 28 | S&F in repair 110 mm dia PVC (SWR) with access door bends any radius complete all as specified and directed |
| 29 | S&F in repair 75 mm dia PVC (SWR) bends any radius complete all as specified and directed |
| 30 | S&F in repair 75 mm dia PVC (SWR) with access door bends any radius complete all as specified and directed |
| 31 | S & F in repair PVC SWR floor trap 75 mm dia with grating incl jointing with solvent cement complete all as specified and direcetd. |
| 32 | S&F in repair110 mm bore PVC (SWR) junction single (single T) equal or unequal with access door complete all as specified and directed |
| 33 | S&F in repair 110 mm bore PVC (SWR) vent Cowl complete all as specified and directed |
| 34 | Dewatering of soak well/soakpit including connected septic tank by discharging the sewage water into a sealed tanker with pipe system including vechicle and other arrangement and disposing within 3.00km outside cantt are complete all as directed .(Note : 4000ltr capacity tank shall be measured as one unit) Please Enable Macros to View BoQ information |