| 1 | Schedule 'A' |
| 2 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 3 | S&F Pre- painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as specified. |
| 4 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip, straight flashing etc fixed with self tapping screws as specified. |
| 5 | S&F 0.50mm thick plain, aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing length and girth as fixed complete all as specified and directed. |
| 6 | Dismantling floor, hearth , chequred tiles, interlocking tiles tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 7 | M & L for 25 mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in sub floor of floor finishes, finished even and rough complete all as specified. |
| 8 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 9 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 10 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 11 | M&L for Non-skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exc 0.38 sqm , in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade and including rendering 10 mm thick on fair faces of brick work in CM 1:4 for recieving vertical dado tiling complete all as specified and directed. |
| 12 | S&F Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile including 10mm thick cement mortar backing in CM (1:4) as backing coat to receive tiles complete all as specified and directed. |
| 13 | Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thick thickness below or above ground level complete all as specified and directed. |
| 14 | Demolition of cement concrete (unreinforced) PCC in any description and in any portion not otherwise specifically provided for complete all as specified and directed. |
| 15 | M&L for 75mm thick cement concrete type D2 1:4:8 (using 40mm graded stone aggregate) as in sub base completed all as specified and directed. (Using Dimapur Sand) |
| 16 | M&L for 75mm thick cement concrete type C2 1:3:6 using 40 mm graded stone aggregate as in plinth protection including finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed. (Using dimapur sand) |
| 17 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. Note :-Dismantling of false ceiling to be carried out carefully without damaging existing fitting and fixtures of flase ceiling items |
| 18 | M&L for 6mm thick plywood (no of ply 05), grade BWR, type BB fixed with nails or screws to timber frame work complete all as specified and directed. |
| 19 | S&F exposed GI powder coated snap grid frame work for false ceiling of grid size 600 x600mm comprising of wall/cleat angle of size 22 x22 x0.35mm and main/cross tee of size 24 x38 x0.35mm with 4mm dia GI wire as suspender and including 4mm thick Plain E-Board including fixing arrangement from steel truss of any type and applying two coats of oil bound distemper over one coat of chalk whiting complete all as specified and directed. |
| 20 | Dismantling of unframed timber scantling 40 sq .cm and over in section,in any position complete all as specified and directed. |
| 21 | M&L for well seasoned 2nd class hard wood in scantling, clean sawn timber framed work complete all as specified and directed. |
| 22 | M&L for preparation of old painted surfaces of steel of any description over 10cm width or girth and applying one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 23 | M&L for preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 24 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but not exc. 4 sqm each complete all as specified and directed. |
| 25 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each complete all as specified and directed. |
| 26 | S&F factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 27 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 28 | Taking down shutters of any description exc 1 sqm and not exc 2 sqm each including easing and adjusting and also refixing builder hardware as required including renewal of unserviceable screw and necessarry materials refixing shutter in same opening complete all as specifeid and directed. |
| 29 | S&F 2nd class hardwood plain solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 30 | S&F 35 mm thick 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauge, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.20 (a) fitted chowkats complete all as specified and directed. |
| 31 | S&F Galvanised mild steel wire cloth 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 32 | S&F 30mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 33 | S&F 150 mm long aluminium anodised of extruded section barrel tower bolts complete all as specified and directed. |
| 34 | S&F 150 mm long aluminium alloy handles,fabricated type, anodised complete all as specified and directed. |
| 35 | S&F 75mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed. |
| 36 | S&F butt hinges, 125mm extruded aluminum alloy with galvanized mild steel hinges pin anodised and fixed type B-21 complete all as specified and directed. |
| 37 | S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed 300mm long complete all as specified and as directed. |
| 38 | S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with 150mm overall length of cover plate complete all as specified and directed. |
| 39 | S&F 300 mm long mild steel ordinary rat tail rod pattern helical door springs including roller and roller plate complete all as specified and directed. |
| 40 | M&L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer on wooden surfaces complete all as specified and directed. |
| 41 | S&F Aluminium powder coated frame/chowkats for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed. |
| 42 | S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc including all fitting complete all specified and directed |
| 43 | S&F sheet glass 3mm thick, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and as directed. |
| 44 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed. |
| 45 | S&F steel work in tubular or square trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to Fe 410-W (Gde-E-250 quality A) complete all as specified and directed. |
| 46 | S & F in repairs fancy type decorative Drapary rod of 20mm dia for window and doors with decorative doom holders fixed to wall with screw complete all as specified and directed. |
| 47 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles and removing unserviceable materials from site of work complete all as specified and directed. |
| 48 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed. |
| 49 | M&L for rendering 15mm thick in CM 1:4 on on fair surfaces of brick in two separate coats (10mm thick backing coat and 5mm thick top coat) using water proofing compound @2% by weight of cement as per manufacture instruction and finishing works/concrete surfaces finished even and smooth complete all as specified and directed.Note : (i) WPC will be measured and paid separately (ii) Rates deemed to be inclusive of scaffolding upto height 12 Mtr at reqd places. No additional payment will be made on this account |
| 50 | M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed. |
| 51 | Supply only intergral water proofing compound complete all as specified and directed. |
| 52 | M&L for preparation of new or previously untreated surfaces of walls and applying two coats of oil bound distemper paint over a coat of primer and 1mm thick wall care putty complete all as specified and as directed. |
| 53 | M&L for preparation for new or previously untreated plastered surface of walls and applying two coats of cement base paint over one coat of primer complete all as specified and directed. |
| 54 | S&F vitreous china European type wash down water closet pan (Pedestal pattern) of white colour including plastic water closet seat cover closed pattern with flat bottom (with MS or CP hinging device) and fixing bolts, P or S trap, necessary inlet and outlet connections including syphonic action type low level PVC flushing cistern of 10 lit capacity of Commander make white in colour and PVC flush pipe 32mm dia complete all as specified and directed. |
| 55 | S&F PVC SWR pipes 110 mm bore single socketed in any length with rubber ring joint fixed to wall or laid in trenches or in floors with steel clamps complete all as specified and directed. |
| 56 | S&F PVC SWR pipes 75 mm bore single socketed in any length with rubber ring joint fixed to wall or laid in trenches or in floors with steel clamps complete all as specified and directed. |
| 57 | S&F 110mm dia PVC SWR branch bends of any radius with acess door complete all as specified and as directed. |
| 58 | S&F 75mm dia PVC SWR branch bends of any radius with acess door complete all as specified and as directed. |
| 59 | S&F PVC (SWR), junction single, (Single T) equal or unequal 110mm dia with access door complete all as specified and directed. |
| 60 | S&F PVC (SWR), junction single, (Single T) equal or unequal 75mm dia with access door complete all as specified and directed. |
| 61 | S&F 75mm dia PVC (SWR) floor trap, plain with grating including setting and jointing with solvent cement complete all as specified and directed. |
| 62 | M&L for PVC (SWR) vent cowl of bore 75mm complete all as specified and directed. |
| 63 | S&F PVC (SWR) WC connector with lip ring 110 mm. complete all as specified and directed. |
| 64 | M & L Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete as specified and directed. |
| 65 | M&L for 15mm thick rendering to sides and bottom of sunken slab in CM 1:3 mixed with water proofing compound, finishing the surfaces even and smooth without using extra cement complete as specified and directed.(Using Dimapur Sand) [Note: WPC will be measured and paid separately) |
| 66 | M&L for 25mm thick cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in sunken floors complete all as specified and directed. |
| 67 | M&L for PCC 1:4:8 Type D2 (Nominal mix) using 40mm graded crushed stone aggregate mixed with water proofing compound @ 3% by weight of cement as in concrete padding, laid to require slope, including finishing the concrete surfaces fair and even without using extra cement complete as specified and directed. (Using Dimapur Sand) [Note: WPC will be measured and paid separately) |
| 68 | S&F GI medium grade spouts 40mm dia projecting at least 20 cm clear of the wall complete all as specified and directed. |
| 69 | M&L for applying two coats of hot bitumen 85/25 grade @ 1.70 Kg/Sqm over vertical surfaces and floor of sunken slab after laying all CI connection branch pieces etc after covering joints with PCC 1:2:4 type B1 complete all as specified and directed. |
| 70 | M&L for PCC 1:7:12 type F2 (using 40mm graded stone aggregate) with bricks as in filling of sunken slab after laying and carrying out required tests for CI pipes joints complete all as specified and directed. |
| 71 | M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in benching, bed coping as Manholes, drain and the like including formwork and finishing all exposed surface of concrete complete all as specified and directed. |
| 72 | M&L for cement concrete type C2 1:3:6 (using 40mm graded aggregates) as in surface channel and drains including necessary form work and finish inside of drain complete all as specified and as directed. |
| 73 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. |
| 74 | M & L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for internal dia of pipe 100mm complete all as specified and directed. |
| 75 | Taking down carefully unserviceable aluminum/ copper point wiring (light/ fan/ socket/ power) complete including fixture & fitting such as switches, sockets, ceiling roses regulators, lamp holder etc. but excluding light fittings & fixture and exhaust fans etc removing and making good disturbed surfaces of wall/ceiling etc complete all as specified and directed. |
| 76 | Material and labour for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc including multi-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc complete all as specified and directed for following :- (Colour code to be followed)One light point controlled by one, one way switch |
| 77 | One ceiling/exhaust fan point controlled by one, one way switch |
| 78 | One socket outlet 5 Amps 5 pin on independent board |
| 79 | One socket outlet 5 Amps 5 pin on same board with other switches |
| 80 | All as per item No. 08 here in before but with cable size 2.5 Sqmm and earth continuity conductor of 2.5 Sqmm size for one 5 pin 15 Amps socket out let on independent board complete all as specified and directed. |
| 81 | S&F modular switch piano, 6 Amps, single pole, one way complete all as specified and directed. |
| 82 | S&F modular socket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed. |
| 83 | Supply and fixing modular Switch Socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module. |
| 84 | S&F Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 85 | S&F modular switch piano, 16 Amps, single pole, one way complete all as specified and directed. |
| 86 | S&F blank spacer plate for single module complete all as specified and directed. |
| 87 | Taking down old unserviceable main switch/ DBs/ MCB DBs with MCB including making good the disturbed surface complete as directed. |
| 88 | S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 8 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door verticle for breaking capacity 10 KA complete all as specified and directed.(Make: Havells or as per list approved makes enclosed hereinafter) |
| 89 | S&F MCB single pole and neutral 40 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
| 90 | S&F MCB single pole 06 to 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
| 91 | S&F PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 250mm x 200mm x 50 mm deep medium quality ISI marked complete all as specified and directed. |
| 92 | Taking down old unserviceable LED tube light fitting / building security light complete all as specified. |
| 93 | S & F LED light fitting 1x20 Watt , 220 V , AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 94 | Supply and Fixing ceiling fans complete with blades, down rods, electronic regulator and accessories , 230 V, 1200 mm sweep. Min air deleivery 210 CFM with service value 6.00 BEE . Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 95 | Supply and fixing LED building secuirty light fittings 25 watt 230 V AC out door type with high pressure dia cast aluminium hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 96 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, poles struts, laying of cables/pipes, etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 97 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soft/loose soil complete all as specified and as directed. |
| 98 | Removing excavated material/soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 99 | Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down 18CM will be measured and paid complete all as specified and directed. (Note: Thickness of sand cushion after punning down will be measured and paid.) |
| 100 | Supply and laying well burnt sub class ‘B’ bricks ( designated 75) locally available best quality, laid dry in trenches for protection of underground cable complete all as specified and directed. |
| 101 | Supply, laying, Jointing and testing in repair of LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 sqmm 4 core laid in trenches / on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. |
| 102 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth wire 4mm dia by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion all as specified and as directed. (Note: Earth strip beyond 7.5 m length will be measured & paid separately) Please Enable Macros to View BoQ information |