| 1 | B/R PORTIONM&L for dismantling water tanks exc 500 and not exc 1000 lts in capacity and removing to store complete all as specified and as directed. |
| 2 | M&L for dismantling of water tanks exc 250 and not exc 500 lts in capacity and removing to store complete all as specified and as directed. |
| 3 | Taking down 15 mm dia bore steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified and as directed. |
| 4 | Taking down 20 mm dia bore steel tubing and connections including cleaning for re-fixing or removal to store complete all as specified and as directed. |
| 5 | Dismantling of plain or corrugated steel sheeting, any guage, thickness, including nainital or similar patter roof coverings complete all as specified and as directed. |
| 6 | Dismantling of framed timber scantling 40 sqcm and over in section, in any position complete all as specified and as directed. |
| 7 | Dismantling wrought iron or mild steel work of any description and any places not otherwise provided for complete all as specified and as directed. |
| 8 | Demolition of RCC water tank, roofs, floors, beams, staircase, landing, parapet, fascia. Shelves. Chhajja and similar suspended work complete all as specified and as directed. |
| 9 | Dismantling of wall and ceiling boards(fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, grid work/ wooden or aluminium frame works etc complete all as specified and as directed. |
| 10 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) not exc. 1.5 sqm each, making good disturbed surfaces and including removing to store complete all as specified and as directed. |
| 11 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) exc. 1.5 sqm and n.exc 4 sqm each, making good disturbed surfaces and including removing to store complete all as specified and as directed. |
| 12 | Taking down cement plaster, any description on brick or stone walls ,etc, including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed. |
| 13 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 14 | Demolition of unreinforced cement concrete in ground flooring and paving n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 15 | Demolition of brickwork built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 16 | S&F of 1000 liters capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed. |
| 17 | S&F of 500 liters capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed. |
| 18 | S&F in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm bore and fixed, minimum weight of float valve 210 gms complete all as specified and as directed. |
| 19 | S&F in repair 20mm bore gun metal, globe or gate valves, with iron wheel head, screwed both ends, for iron pipe and fixed complete all as specified and as directed. |
| 20 | M&L for cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc; and for concelead water tubing or concealed conduit wiring, etc and making good, cutting n. exc 10 cm girth in brick wall complete all as specified and as directed. |
| 21 | Supplying and laying of 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed. |
| 22 | Supplying and laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed. |
| 23 | S & F of pre-painted galvalume aluminium zinc coating GI based corrugated/ semi corrugated/ trapezoidal sheet 0.80 mm thick (BMT) of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and as directed. |
| 24 | S & F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.80 mm thick (BMT) of any colour having tensile strength of 550 Mpa as in roof ridge, covering/ cladding to wall fixed with self tapping screws or \\"J\\" hook complete all as specified and as directed. |
| 25 | M&L for 2nd class hardwood wrought in scantling timber framed and fixed complete. all as specified and as directed. |
| 26 | M&L for preparing surfaces of wood and wood based materials new or old of any description and girth not otherwise described and treated with creosote oil complete all as specified and directed. |
| 27 | M&L for roof trusses (framed/ un framed) for purline, rafter, crane gantries, door frame, post, rails and fastening and heavy bracket framings etc (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W (Gde E- 250) quality A complete all as specified and directed. |
| 28 | S & F of steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 29 | S & F of plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe 410-W (Gde E- 250) quality A complete all as specified and directed. |
| 30 | S&F of bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 31 | M&L for excavating in post holes (or similar holes) each n exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in soft and loose soil complete all as specified and as directed. |
| 32 | M & L for PCC (1:2:4) Type B-2 (using 40mm graded aggregate) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and as directed. |
| 33 | S&F for powder coated galvanised iron snap grid frame work of size 600 x 600 mm for false ceiling comprising of Main runner 'T' section of size 38mm x 24mm x 0.40mm thickness, Cross 'T' of size 29mm x 24mm x 0.3mm thickness and wall angle of size 24mm x 24mm x 0.43mm thick suspended with 4mm dia GI wire from purlin @ 1.20m c/c and fixed with 4mm thick designer ceiling boards complete all as specified and as directed. |
| 34 | S&F for 1.25 mm thick pressed steel frame of size 125 X 60 mm for door with one or more rebates includings necessary fixing lugs, stainless steel hinges, lock strike plate etc complete all as specified and as directed |
| 35 | S&F for 1.25 mm thick pressed steel frame of size 105 X 60 mm for door with one or more rebates includings necessary fixing lugs, stainless steel hinges, lock strike plate etc complete all as specified and as directed |
| 36 | M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, holdfast, kneelers, apex stones bed plates, kerbs with rounded or chamfered edges, water troughs and the like including weathering, slightly rounded or chamfered angles, necessary formwork, and throating complete all as specified and as directed. |
| 37 | M & L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint on steel surfaces complete all as specified and as directed. |
| 38 | S & F of powder coated aluminium sliding window shutters with frames (consisting of two nos glazed shutters and one no gauze shutter) series-D (25mm) 3 track sliding shutters, duly fitted with neoprene beading glazing clip, locking device, heat absorbing glass 4 mm nominal thickness in glazed shutters, stainless steel wiremesh of 0.36mm nominal dia of wire and 1.18 mm average width of aperature in gauzed shutter complete all as specified and as directed. |
| 39 | S&F of powder coated anodized aluminum frame for doors, windows ventilations with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. |
| 40 | S & F of powder coated Anodised aluminium window and ventilator shutters side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21 100 mm long (2 nos), suitable handle 1 No complete all as specified and as directed. |
| 41 | S&F of 4 mm thick one side frosted sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5sqm in each pane fixed with neoprene rubber gasket in aluminium frame complete all as specified and as directed. |
| 42 | S&F of 4 mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5sqm in each pane fixed with neoprene rubber gasket in aluminium frame complete all as specified and as directed. |
| 43 | S&F of 9 mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws complete all as specified and as directed. |
| 44 | S&F of 35mm thick second class hardwood factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 45 | S&F of 35mm thick second class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats complete all as specified and as directed. |
| 46 | S&F of 25mm thick block boards, grade 2 quality, interior grade, decorative type with decorative face veneer one face, fixed with screw to timber or steel frame work complete all as specified and as directed. |
| 47 | S&F of 18 to 19mm thick block board grade 2 quality interior grade decorative type with decorative face veneer on one face fixed with screws to timber framework as in shelves, drawers etc complete all as specified and as directed. |
| 48 | M & L for preparation of new wooden surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 49 | S&F of 75 mm hasp & staple, safety type, aluminium anodised with mild steel steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed. |
| 50 | S&F of stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples including necessary beading complete all as specified and as directed. |
| 51 | S&F of solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. tube complete all as specified and as directed. |
| 52 | S&F of factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm Plan colour PVC sheet on back face with particle board core complete all as specified and as directed. |
| 53 | S&F of 100 mm butt hinges, medium weight cold rolled, stainless steel and fixed complete all as specified and ab directed. |
| 54 | S&F of 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and ab directed. |
| 55 | S&F of 150mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and ab directed. |
| 56 | S&F of 300mm long aluminium alloy, anodised sliding door bolt with hasp & stapple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast- aluminium alloy and fixed complete all as specified and ab directed. |
| 57 | S&F of 150mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and ab directed. |
| 58 | S&F of 125mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and ab directed. |
| 59 | S&F of 300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and ab directed. |
| 60 | S&F of framed work such as grills, gratings, etc. with ends of bar shouldered and/or revited, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings framework of water tanks and similar works confirming to Fe 290 Gde E-165 complete all as specified and ab directed. |
| 61 | M & L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 62 | S&F in repair of 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 63 | S&F in repair of 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed. |
| 64 | S&F in repair of 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed. |
| 65 | S&F in repair of 110mm bore PVC (SWR) vent cowl complete all as specified and as directed. |
| 66 | S&F in repair of 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 67 | S&F in repair of 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 68 | S&F in repair of 110 mm bore PVC (SWR) junction single (single T) equal or unequal complete all as specified and as directed. |
| 69 | S&F in repair of 75 mm bore PVC (SWR) junction single (single T) equal or unequal complete all as specified and as directed. |
| 70 | S&F in repair PVC (SWR) floor trap plain with grating having diameter of outlet 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. |
| 71 | S&F in repair of 600 mm x 450 mm size beveled edge mirror of selected quality glass, 5.50 mm thick, mounted on 6mm thick AC building board or commercial plywood and fixed to wall with wooden plugs and chromium plated brass screws and cup washers complete all as specified and as directed. |
| 72 | S&F in repair of CP toilet paper holder with flat recessed type stainless steel fixed to walls with chromium plated brass screws complete all as specified and as directed. |
| 73 | S&F in repair of CP soap dish fixed to wall with screw complete all as specified and as directed. |
| 74 | S&F in repair of 20 mm dia Aluminium anodised tubular towel rail, D type, 60 cm long between flanges fixed with brass screws complete all as specified and as directed. |
| 75 | S&F in repair of brass chromium plated shower rose 125mm size with or with out swivel joints, any size including fixing to steel pipe or union complete all as specified and as directed. |
| 76 | S&F in repair of chromium plated hand shower (health faucet), telephonic type with 8mm dia, 1 meter long pvc tube cover CP flexible with wall hook and jet of approved make, suitable for 15 mm bore iron pipes or for unions and fixed complete all as specified and as directed. |
| 77 | S&F in repair of 15 mm bore chromium plated fancy type angle stop valves with elegant knob screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 78 | S&F in repair of 15 mm bore chromium plated fancy type stop cock (concealed type) with long shank and cup with elegant knob screwed down high pressure, with crutch or butter fly handle screwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 79 | S&F in repair of 15 mm bore chromium plated fancy type long boby bib taps with crutch or buttrfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. |
| 80 | S&F in repair of angular two way angle cock with wall flange, 15 mm nominal bore cast copper alloy, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions complete all as specified and as directed. |
| 81 | S&F in repair of 15 mm bore chromium plated fancy type pillar tap for WHBs with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and as directed. |
| 82 | S&F in repair of PVC connection of 15mm dia and 450 mm long with 2 Nos PTMT nuts with washers complete all as specified and as directed. |
| 83 | S&F in repair of PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action type with inlet ball valve, float and handle including brackets and PVC flush pipe 32 mm bore complete all as specified and as directed. |
| 84 | S&F in repair of white vitreous China wash down water closet pan (pedestal pattern) excluding fixing bolts, flushing cistern and flush pipe, and pedestial pan and trap including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. complete all as specified and as directed. |
| 85 | S&F in repair of plastic water closet seat and cover for pedestal pan, white, closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 86 | S&F in repair of Vitreous China Half Stall urinal flat back, size of 600 x 395 x 365 mm white, with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) but including connection to flushing pipe and outgoing pipes complete all as specified and as directed. |
| 87 | S&F of Glass 6 mm thick heat strengthened glass with both side acid frost finish size 450 x 900 mm cut & finish and fixed on wall using SS 304 Heavy L bracket complete all as specified and as directed. |
| 88 | S&F of urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and as directed. |
| 89 | S&F in repair of vitreous china wash hand basin (Oval type) of size 550x400mm including one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector, including cutting for and pinning in ends of brackets complete all as specified and as directed. |
| 90 | M&L for preparation of old painted wood or wooden based surfaces of any description not otherwise described exc. 10 cm in width or girth and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified and as directed. |
| 91 | M&L for preparation of old painted steel surfaces of any description not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified and as directed. |
| 92 | M&L for complete removal of existing treatment of surfaces and applying 1.5mm thick wall care putty to old plastered surfaces of walls and applying two coats of oil bound distemper complete all as specified and as directed. |
| 93 | M&L for preparation of old surfaces of wall and applying two coats of exterior weather coat for camouflage design incl necessary scaffolding complete all as specified and as directed. |
| 94 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 95 | M & L for Cement Concrete (1:4:8) Type D-2 (using 40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 96 | M & L for RCC 1:2:4 Type B-1 (Nominal mix) (using 20 mm graded aggregate) as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under-reamed piles and mass concrete complete all as specified and as directed Note:- Reinforcement shall be measured and paid separately. |
| 97 | M & L for RCC 1:2:4 Type B-1 (Nominal mix) (using 20 mm graded aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed Note:- Reinforcement shall be measured and paid separately. |
| 98 | M & L for RCC 1:2:4 Type B-1 (Nominal mix) (using 20 mm graded aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed Note:- Reinforcement shall be measured and paid separately. |
| 99 | M & L for RCC 1:2:4 Type B-1 (Nominal mix) (using 20 mm graded aggregate) as in chajjas complete all as specified and as directed Note:- Reinforcement shall be measured and paid separately. |
| 100 | M & L for RCC 1:2:4 Type B-1 (Nominal mix) (using 20 mm graded aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed Note:- Reinforcement shall be measured and paid separately. |
| 101 | M & L for brick work with sub-class `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 102 | M & L for brick work with sub-class `B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 103 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/ loose soil complete all as specified and directed.. |
| 104 | Removing excavated material exc. 250m but n exc. 500m and depositing where directed at a level not exc. 1.50m above the starting point complete all as specified and directed. |
| 105 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and sofits (if any) of foundation and plinth beams and similar work; vertical or to batter etc complete all as specified and as directed. |
| 106 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed. |
| 107 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, chajjas, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed. |
| 108 | M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, fascia and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 109 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar works exc 5 cm but not exc. 10 cm wide for rough finished surfaces of concrete complete all as specified and directed. |
| 110 | S&F of TMT bar Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 111 | S&F of TMT bar Mild steel bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 112 | S&F of TMT bar Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 113 | M&L for sand filling under floors or in foundations, cushioning of cables including watering and consolidation complete all as specified and as directed.Note:- Punned depth will be measured and paid. |
| 114 | M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 115 | M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded aggregate) as in sub-floors, sub-bases etc. complete all as specified and as directed |
| 116 | M&L for 25 mm thick Cement concrete type B-0 1:2:4 (using 12.5 mm graded aggregate) as in sub floors etc incl finishing the surface even and rough to receive screeding complete all as specified and as directed |
| 117 | M&L for Virified Ceramic tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, laid over screed bed or bedding layer of CM 1:6 of 15mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 118 | M&L for Virified Ceramic tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skriting/vertical surface laid over and including 10mm thick rendering in CM 1:4 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 119 | M & L for non skid coloured ceramic floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc. 0.11 sqm but not exceeding 0.18 sqm each 6-8mm thick as in floors laid over and including 15mm thick screed bed in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 120 | M & L for coloured glazed ceramic wall tiles of size 450x350x6-7mm thick on vertical surfaces laid over and including for rendering 10mm thick in CM (1:4) on vertical surface of wall.cement screed bet set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 121 | M & L for Machine cut kota stone slab flooring 20 -25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 20 mm thick screed bed in CM 1:6 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified including rubbing and polish complete all as specified and as directed |
| 122 | M & L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slabincluding 10mm thick rendering in CM 1:4 etc. set and jointed in neat cement slurry and pointed including rubbing and polish complete all as specified and as directed |
| 123 | M&L for Granite (of any type) tiles 18-20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over and including 15mm thick screed bed in CM 1:6, including grinding and polishing complete all as specified and as directed.. |
| 124 | M & L for Providing cement concrete (1:3:6) Type C-1 (using 20mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, holdfast, kneelers, apex stones bed plates, kerbs with rounded or chamfered edges, water troughs and the like including weathering, slightly rounded or chamfered angles, necessary formwork, and throating complete all as specified and as directed. |
| 125 | M & L for chequered coloured cement concrete tiles 30cmx30cmx25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment in floors over 20mm thick screed bed in CM 1:6 complete all as specifed and as directed |
| 126 | M&L for 10 mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces on wall complete all as specified and as directed |
| 127 | M&L 15 mm thick rendering in CM 1:4 in two layers (10 mm thick in first layer and 5 mm thick in second layer) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement with using WPC 3% by weight of cement on wall complete all as specified and as directed. Note:- WPC shall be measured and paid seperately |
| 128 | Supply only water proofing compound complete all as specified and as directed. |
| 129 | M&L for preparation of new surfaces of and applying two coats of oil bound distemper over a coat of alkhali resistant primer over a coat of wall care putty 1.5 mm thick complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 130 | M&L for preparation of new surfaces of and applying two coats of oil bound distemper over a coat of alkhali resistant primer over a coat of wall care putty 1.5 mm thick complete all as specified and as directed. Please Enable Macros to View BoQ information |