Name of Work:- SPECIAL REPAIRS AGAINST BER COOLING APPLIANCES AT AFS YELAHANKA
Sl. No.
Item Description
1
M&L for dismantling Air conditioner split/window type of capacity 1.5/2/3 TR from existing location including unsv copper tubing and other items and depositing to MES store yard for further disposal complete all as specified and directed.
2
Supply, install, testing and commissioning hi wall invertor split units indoor/outdoor with invertor compressor with adjust power depending on load complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating As per BEE guidelines and ISEER Value 3.90 for air conditioner of capacity 1.5 TR including making core cutting complete all specified and directed.
3
Supply, install, testing and commissioning hi wall invertor split units indoor/outdoor with invertor compressor with adjust power depending on load complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating As per BEE guidelines and ISEER Value 3.95 for air conditioner of capacity 2 TR including making core cutting complete all specified and directed.
4
Supply, install, testing and commissioning hi wall invertor multi split units with two indoor unit and one outdoor unit with invertor compressor with adjust power depending on load complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating As per BEE guidelines and ISEER Value 3.95 for air conditioner of capacity 3.0 TR including making core cutting complete all specified and directed.
5
Supply, install, testing and commissioning of invertor type ductable air conditioning system, of capacity minimum 5 TR, comprising of indoor and outdoor unit with invertor compressor of capacity minimum 5 TR capacity with R-410A Gas as refrigerant complete all as specified and directed with following items :-(i) CPVC drain piping of size 32mm from indoor units till nearest drain points with necessary bends and fittings as per site requirement.(ii) MS Stand for Outdoor ductable unit duly painted with two coats of red oxide over a coat of black synthetic enamel paint as per site requirement .(iii) Cable of size 4Cx 2.5 Sqmm from outdoor unit to indoor unit as per recommendation of OEM as required at site.(iv) Power cable of size 4C x 10 Sqmm from nearest power source to outdoor unit as per recommendation of OEM as required at site.(v) Open and closed cell nitrile rubber for acoustic insulation of thickness 10mm for insulation of copper tubing from outdoor unit to indoor unit as per site requirements.(vi) GI volume control dumper of suitable size as per recommendation of OEM and as required at site. (vii) Grills with collar damper of suitable size as per recommendation of OEM as required at site. (viii) Fire retardant flexible canvas connection as per recommendation of OEM and as required at site. (ix) Installation of factory made GI Duct of size 24G/22G with angle flanges / support, joints, gasket, bolts & nuts etc compete all as per recommendation of OEM and approved by accepting officer . Make : Blue Star/ Hitachi / Lloyd/LG. Please Enable Macros to View BoQ information
6
Supply, install, testing and commissioning of invertor type ductable air conditioning system, of capacity minimum 5 TR, comprising of indoor and outdoor unit with invertor compressor of capacity minimum 5 TR capacity with R-410A Gas as refrigerant complete all as specified and directed with following items :-(i) CPVC drain piping of size 32mm from indoor units till nearest drain points with necessary bends and fittings as per site requirement.(ii) MS Stand for Outdoor ductable unit duly painted with two coats of red oxide over a coat of black synthetic enamel paint as per site requirement .(iii) Cable of size 4Cx 2.5 Sqmm from outdoor unit to indoor unit as per recommendation of OEM as required at site.(iv) Power cable of size 4C x 10 Sqmm from nearest power source to outdoor unit as per recommendation of OEM as required at site.(v) Open and closed cell nitrile rubber for acoustic insulation of thickness 10mm for insulation of copper tubing from outdoor unit to indoor unit as per site requirements.(vi) GI volume control dumper of suitable size as per recommendation of OEM and as required at site. (vii) Grills with collar damper of suitable size as per recommendation of OEM as required at site. (viii) Fire retardant flexible canvas connection as per recommendation of OEM and as required at site. (ix) Installation of factory made GI Duct of size 24G/22G with angle flanges / support, joints, gasket, bolts & nuts etc compete all as per recommendation of OEM and approved by accepting officer . Make : Blue Star/ Hitachi / Lloyd/LG. Please Enable Macros to View BoQ information