| 1 | Schedule 'A' |
| 2 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 3 | S&F Pre- painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as specified. |
| 4 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip, straight flashing etc fixed with self tapping screws as specified. |
| 5 | Dismantling Timber Boarding, in any description, fixed in any position with Nails, etc. complete all as specified and as directed. |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed. |
| 7 | S&F steel work in tubular or square trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to Fe 410-W (Gde-E-250 quality A) complete all as specified and directed. |
| 8 | S&F Mild steel Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc conforming to Fe 290-W (Grade E-165) quality-A complete all as specified and as directed. |
| 9 | Dismantling of unframed timber scantling 40 sq .cm and over in section,in any position complete all as specified and directed. |
| 10 | M&L for well seasoned 2nd class hard wood in scantling, clean sawn timber framed work complete all as specified and directed. |
| 11 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.Note :-Dismantling of false ceiling to be carried out carefully without damaging existing fitting and fixtures of flase ceiling items |
| 12 | S&F exposed GI powder coated snap grid frame work for false ceiling of grid size 600 x600mm comprising of wall/cleat angle of size 22 x22 x0.35mm and main/cross tee of size 24 x38 x0.35mm with 4mm dia GI wire as suspender and including 4mm thick Plain E-Board including fixing arrangement from steel truss of any type and applying two coats of oil bound distemper over one coat of chalk whiting complete all as specified and directed. |
| 13 | M&L for 6mm thick plywood (no of ply 05), grade BWR, type BB fixed with nails or screws to timber frame work complete all as specified and directed. |
| 14 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but not exc. 4 sqm each complete all as specified and directed. |
| 15 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each complete all as specified and directed. |
| 16 | S&F 2nd class hardwood plain solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 17 | S&F 30mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and as directed. |
| 18 | S&F 25mm thick 2nd class HW glazed skeleton shutters open rebated and prepared to receive glass gazed etc but divided into squares with plain chamfered or rounded mitred and rebated sash bar any numbers edges of framing plain chamfered or rounded fitted with cut and mittered beads for sceuring glass guage etc. size of members as specified in SSR pt-I section 8 clause 8.24(a) fitted to chowkhats complete all as specified and directed. |
| 19 | S&F Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 20 | Supply and fix solid PVC door frame of size 50mm x 47mm made out of 5mm single piece extruded PVC profiles reinforced with 19 x 19mm MS square tube provided with EPDM rubber gasket weather seal through out the frame and the profile mitre cut at two corners and joined by inserting 2 nos 150mm long brackets of 15 x 15mm MS square tube inside 19 x 19mm MS square tube suitably screwed complete all as specified and as directed. |
| 21 | Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes of size 15 x 15mm for top and bottom rails and 19 x 19mm for stiles, MS frame covered with 5mm thick single piece extruded PVC profile 'C' channel having a 5mm thick PVC sheet strip of 20mm width struck inside with solvent cement, forming stiles, and 5mm thick single piece extruded PVC profile for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail; panelling of 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with PVC sheet beading, and joined together with solvent cement adhesive etc all as per manufacturer's instructions and drawings as shown in SSR Part-I 2009 complete all as specified and as directed. |
| 22 | S&F Aluminium powder coated frame/chowkats for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed. |
| 23 | S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc including all fitting complete all specified and directed |
| 24 | S&F sheet glass 5.5mm thick, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and as directed. |
| 25 | S&F Galvanised mild steel wire cloth 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 26 | S&F 100 mm butt hinges medium weight cold rolled mild steel complete all as specified and directed. |
| 27 | S&F 75 mm butt hinges medium weight cold rolled mild steel complete all as specified and directed. |
| 28 | S&F 150 mm long aluminium anodised of extruded section barrel tower bolts complete all as specified and directed. |
| 29 | S&F 200 mm long aluminium anodised of extruded section barrel tower bolts complete all as specified and directed. |
| 30 | S&F 150 mm long aluminium alloy handles,fabricated type, anodised complete all as specified and directed. |
| 31 | S&F floor door stopper of brass body and tongue, with hard drawn steel spring, fixed in floor with 140mm overall length of cover plate complete all as specified and directed. |
| 32 | S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed 300mm long complete all as specified and as directed. |
| 33 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles and removing unserviceable materials from site of work complete all as specified and directed. |
| 34 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed. |
| 35 | M & L for brick work with sub class ‘B’ brick straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed. |
| 36 | M&L for rendering 15mm thick in CM 1:4 on on fair surfaces of brick in two separate coats (10mm thick backing coat and 5mm thick top coat) using water proofing compound @2% by weight of cement as per manufacture instruction and finishing works/concrete surfaces finished even and smooth complete all as specified and directed.Note : (i) WPC will be measured and paid separately (ii) Rates deemed to be inclusive of scaffolding upto height 12 Mtr at reqd places. No additional payment will be made on this account |
| 37 | M&L for rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed. |
| 38 | Supply only intergral water proofing compound complete all as specified and directed. |
| 39 | M&L for preparation of new or previously untreated surfaces of walls and applying two coats of oil bound distemper paint over a coat of primer and 1mm thick wall care putty complete all as specified and as directed. |
| 40 | M&L for preparation for new or previously untreated plastered surface of walls and applying two coats of cement base paint over one coat of primer complete all as specified and directed. |
| 41 | M&L Preparation of old painted surfaces of wood based material exc 10 cm width or girth & applying one coat of synthetic enamel paint on wooden surfaces complete all as specified and directed. |
| 42 | M&L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer on wooden surfaces complete all as specified and directed. |
| 43 | M&L for preparation of newly painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coats of synthetic enamel paint over a coat of red oxide, zinc chrome complete all as specified and directed. |
| 44 | Demolition Cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness below or above ground level complete all as specified and as directed |
| 45 | Demolition of cement concrete (unreinforced) PCC in any description and in any portion not otherwise specifically provided for complete all as specified and directed. |
| 46 | M&L for 75mm thick cement concrete type C2 1:3:6 using 40 mm graded stone aggregate as in plinth protection including finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.(Using dimapur sand) |
| 47 | M&L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade 'A' complete all as specified and directed. |
| 48 | M&L for 75mm thick cement concrete type D2 1:4:8 (using 40mm graded stone aggregate) as in sub base completed all as specified and directed. (Using Dimapur Sand) |
| 49 | M & L for 25 mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in sub floor of floor finishes, finished even and rough complete all as specified. |
| 50 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 51 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 52 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 53 | S&F Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile including 10mm thick cement mortar backing in CM (1:4) as backing coat to receive tiles complete all as specified and directed. |
| 54 | Taking up or down 15mm dia of steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed. |
| 55 | Taking up or down 20mm dia of steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed. |
| 56 | S&F GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 57 | S&F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 58 | S&F in repair 15mm bore bib taps, cast copper alloy, chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferule complete all as specified and directed. |
| 59 | S&F in repair Pillar taps, 15mm dia cast copper alloy, with capstan heads, chromium plated, but fancy type screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 60 | S&F in repair stop valve 20 mm dia cast copper alloy, secrewed down high pressure, with crutch or butterfly handle secrewed both ends for iron pipe and fixed complete all as specified and directed. |
| 61 | S&F in repair stop valves, ISI marked, 15 mm dia cast copper alloy, chromium plated, fancy type, with long shank and cup (concealed type) screwed down high pressure, screwed both ends for iron pipe or unions complete all as specified and directed. |
| 62 | S&F in repair 20 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 210 g m s) complete all as specified and directed. |
| 63 | S&F in repair 125mm size chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed. |
| 64 | S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 65 | S & F in Vitreous china wash basin,white flat back,size 630X450 mm including brackets PVC waste pipe 32 mm dia , 32 mm dia waste coupling PTMT (half or full threaded ) ,fibre reinforced PVC connection 45 cm long with PTMT nuts at both end complete all as specified and directed. |
| 66 | S&F PVC connection 15 mm x 450 mm including brass check nut at both ends screwed for iron pipe of 15 mm bore complete all as specified and directed. |
| 67 | S&F Vitreous China Squatting pan, \\"Orissa\\" pattern, size 580 x 440 mm white with integral foot rests and 10 litres PVC capacity valve less, Syphonic action type, Flushing cistern, low level, white with inlet, ball valve, float and handle including brackets (SLIM LINE or equivalent) including PVC Flush pipe 32 mm dia., and setting the trap and pan in lime concrete 1:2:5 minimum 150 mm thick all round and finished just below level of rim of pan to receive the floor finishing complete all as specified and directed. |
| 68 | S&F vitreous china European type wash down water closet pan (Pedestal pattern) of white colour including plastic water closet seat cover closed pattern with flat bottom (with MS or CP hinging device) and fixing bolts, P or S trap, necessary inlet and outlet connections including syphonic action type low level PVC flushing cistern of 10 lit capacity of Commander make white in colour and PVC flush pipe 32mm dia complete all as specified and directed. |
| 69 | S&F in repair Angle stop valve of PTMT of any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) complete all as specified and directed. |
| 70 | S&F in repair brass chromium plated, 600mm long between flanges tubular towel rail , 20mm dia, D type. fixed with and including chromium plated brass screws and wooden plastic cleats, complete all as specified and directed. |
| 71 | S&F in repair Soap dish, CP, white, approximate size 160x 160x90mm Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engr-in- Charge. |
| 72 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 73 | S&F in repair PVC SWR pipes 110 mm bore single socketed in any length with rubber ring joint fixed to wall or laid in trenches or in floors with steel clamps complete all as specified and directed. |
| 74 | S&F in repair PVC SWR pipes 75 mm bore single socketed in any length with rubber ring joint fixed to wall or laid in trenches or in floors with steel clamps complete all as specified and directed. |
| 75 | S&F 110mm bore PVC (SWR) bends complete all as specified and directed. |
| 76 | S&F 75mm bore PVC (SWR) bends complete all as specified and directed. |
| 77 | S&F PVC (SWR), junction single, (Single T) equal or unequal 110mm dia with access door complete all as specified and directed. |
| 78 | S&F PVC (SWR), junction single, (Single T) equal or unequal 75mm dia with access door complete all as specified and directed. |
| 79 | S&F 75mm dia PVC (SWR) floor trap, plain with grating including setting and jointing with solvent cement complete all as specified and directed. |
| 80 | S&F PVC (SWR) P trap of 110 mm bore complete all as specified and directed. |
| 81 | S&F PVC (SWR) S trap of 110 mm bore complete all as specified and directed. |
| 82 | S&F Grating doom 100 mm dia without waste hole of PTMT (minimum weight - 25 gms) complete all as specified and directed. |
| 83 | S&F Grating doom 125 mm dia with waste hole of PTMT (minimum weight - 100 gms) complete all as specified and directed. |
| 84 | M&L for PVC (SWR) vent cowl of bore 75mm complete all as specified and directed. |
| 85 | S&F PVC (SWR) WC connector with lip ring 110 mm. complete all as specified and directed. |
| 86 | Dismantling Water Tanks & removing from site to store of capacity of tanks 500 ltr and n exc 1000 ltr complete all as specified and directed. |
| 87 | S&F rotational moulded polyethylene water storage tank, ISI marked, 1000 litres capacity of multilayered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including all necessary inlet/outlet connections complete all as specified in SSR Part-I and as directed. |
| 88 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and getting out in soft and loose soil complete all as specified and directed. |
| 89 | M&L for providing plain cement concrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates,kerbs water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 90 | M&L for RCC (Nominal Mix) type B1 1:2:4 (20mm graded aggregate ) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.(Sand :- Dimapur) Note :- Reinforcement and form work required shall be measured and paid seperately. |
| 91 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc rough finised flat surfaces of concrete complete all as specified and directed. |
| 92 | M & L for PCC 1:4:8 Type D2 (Nominal mix) (using 40mm graded stone aggregate), as in foundation, filling and mass concrete complete all as specified and as directed.(Note:- using dimapur sand) |
| 93 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 94 | Ditto as per item no 117.00 here-in-above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 95 | M & L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for internal dia of pipe 100mm complete all as specified and directed. |
| 96 | Taking down carefully unserviceable aluminum/ copper point wiring (light/ fan/ socket/ power) complete including fixture & fitting such as switches, sockets, ceiling roses regulators, lamp holder etc. but excluding light fittings & fixture and exhaust fans etc removing and making good disturbed surfaces of wall/ceiling etc complete all as specified and directed. |
| 97 | Material and labour for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc including multi-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc complete all as specified and directed for following :- (Colour code to be followed)One light point controlled by one, one way switch |
| 98 | One ceiling/exhaust fan point controlled by one, one way switch |
| 99 | One socket outlet 5 Amps 5 pin on independent board |
| 100 | One socket outlet 5 Amps 5 pin on same board with other switches |
| 101 | All as per item No. 08 here in before but with cable size 2.5 Sqmm and earth continuity conductor of 2.5 Sqmm size for one 5 pin 15 Amps socket out let on independent board complete all as specified and directed. |
| 102 | S&F modular switch piano, 6 Amps, single pole, one way complete all as specified and directed. |
| 103 | S&F modular socket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed. |
| 104 | Supply and fixing modular Switch Socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module. |
| 105 | S&F Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 106 | S&F modular switch piano, 16 Amps, single pole, one way complete all as specified and directed. |
| 107 | Taking down old unserviceable main switch/ DBs/ MCB DBs with MCB including making good the disturbed surface complete as directed. |
| 108 | S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 8 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door verticle for breaking capacity 10 KA complete all as specified and directed.(Make: Havells or as per list approved makes enclosed hereinafter) |
| 109 | S&F Sheet metal enclousre(for DB's when MCB to be used) single pole and neutral double door with rated bus bar 200 Amps, 4way, 240 Volts without MCB complete all as specified and directed. |
| 110 | S&F MCB single pole and neutral 40 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
| 111 | S&F MCB single pole and neutral 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
| 112 | S&F MCB single pole 06 to 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
| 113 | S&F PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 250mm x 200mm x 50 mm deep medium quality ISI marked complete all as specified and directed. |
| 114 | S&F PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 350mm x 300mm x 50 mm deep medium quality ISI marked complete all as specified and directed. |
| 115 | M&L for submain wiring with single core 6.0 sqmm PVC FRLS insulated unsheathed cable multi stranded copper conductor drawn through and inclduing PVC casing / capping of suitable size with all fittings and fixing accessories on roof , walls, ceiling etc including 4.00 Sqmm PVC insulated unsheathered one core multistranded copper condutor earth wire complete all as specified and directed. (Note : Two run of single core cable and one run earth wire will be measured as one length) |
| 116 | Material and labour for sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 2.5 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing / capping of suitable size with all fittings and fixing accessories ISI marked on roof , wall , ceiling etc. and including cutting chases for conduits & making good to walls, floors etc complete all as specified and as directed. (Note : Two run of single core cable and one run earth wire will be measured as one length) |
| 117 | Taking down old unserviceable LED tube light fitting / building security light complete all as specified. |
| 118 | S & F LED light fitting 1x20 Watt , 220 V , AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 119 | M&L for Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendent/Angle type including one lamp complete all as specified and directed. |
| 120 | S&F of 1100 volts grade heavy duty cabled PVC insulated aluminium conductor served with inner sheating of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than one meter apart including 4 mm suspension wire one twin core cable 2 core flat of 10 sqmm size complete all as specified and directed. |
| 121 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and directed. |
| 122 | Supply and fixing LED building secuirty light fittings 25 watt 230 V AC out door type with high pressure dia cast aluminium hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 123 | Supply and Fixing ceiling fans complete with blades, down rods, electronic regulator and accessories , 230 V, 1200 mm sweep. Min air deleivery 210 CFM with service value 6.00 BEE . Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 124 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed. |
| 125 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, poles struts, laying of cables/pipes, etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 126 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soft/loose soil complete all as specified and as directed. |
| 127 | Removing excavated material/soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. |
| 128 | Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down 18CM will be measured and paid complete all as specified and directed. (Note: Thickness of sand cushion after punning down will be measured and paid.) |
| 129 | Supply and laying well burnt sub class ‘B’ bricks ( designated 75) locally available best quality, laid dry in trenches for protection of underground cable complete all as specified and directed. |
| 130 | Supply, laying, Jointing and testing in repair of LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core laid in trenches / on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. |
| 131 | Supply, installation, testing and commissioning hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary , electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated Complete all as specified and as directed. |
| 132 | Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of current carrying capacity 20 Amp,10KA breaking capacity complete all as specified and directed. |
| 133 | Supply and Fix Voltage stabilizer wall mounted for automatic operation,single phase naturally air cooled indoor type equipped with electronic circuit , relays , time delay , voltmeter etc., designed for input variation between 160 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA complete all as specified and directed. |
| 134 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth wire 4mm dia by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion all as specified and as directed. (Note: Earth strip beyond 7.5 m length will be measured & paid separately) Please Enable Macros to View BoQ information |