| 1 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 3 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 5 | Foundations, footings, bases for columns |
| 6 | 12mm Cement Plaster of mix: |
| 7 | 1:4 (1 cement : 4 fine sand) |
| 8 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 9 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 10 | W.C. pan with ISI marked white solid plastic seat and lid |
| 11 | Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer-in-charge. (The pipe length inserted in the fitting shall not be measured for payment) Inernal work - Exposed on wall |
| 12 | 34.00 mm outer dia Pipe |
| 13 | Finishing walls with textured exterior paint of required shade : |
| 14 | Old work (One or more coats) applied @ 1.82 ltr/10 sqm. |
| 15 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. |
| 16 | One or more coats on old work |
| 17 | Providing and fixing CP brass health Faucet of approved quality and colour : |
| 18 | 15 mm nominal bore |
| 19 | ELECTRICAL WORKS |
| 20 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with piano type switch, suitable size PVC box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 21 | Group C |
| 22 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required |
| 23 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 24 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 25 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required |
| 26 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB /Isolator) |
| 27 | 2 way, Single door |
| 28 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 29 | Single Pole |
| 30 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 31 | 40 Amps, 2 Pole Isolator |
| 32 | Supplying of prewired LED tube light 20W LUMEN output 2000lm 6500K Product code PANASONIC PBTM02203 or equivalent to ISI standard.(Havells/Panasonic/Polycab) or Equivalent to ISI Standarad. |
| 33 | Installation, testing and commissioning of pre-wired, LED FITING of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 34 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 35 | Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 36 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthingas required. |
| 37 | Supplying and fixing rewirable porceline with fuse unit of 32 to 40 amps on energy meter board. |
| 38 | Supplying and fixing of Wooden meter board of Size 10\\" X 12\\" for fixing of Energy meter or equivalent to ISI standarad. Please Enable Macros to View BoQ information |