| 1 | Providing, Laying, Fixing and Jointing of P.V.C. Pipes as per ISI-4985 (ISI mark with the prior approval of Engineer in Charge along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.specifications for Manually Excavation including speicals (6kgf/ cm2) Pressure |
| 2 | PVC pipe 63mm o/d PVC 6 kg/cm2 |
| 3 | PVC pipe 75 mm o/d PVC 6 kg/cm2 |
| 4 | Providing, Laying, Fixing and Jointing of P.V.C. Pipes as per ISI-4985 (ISI mark with the prior approval of Engineer in Charge along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. for more than 3 mtr. Street width.(Mechanically ) (6kgf/ cm2) Pressure |
| 5 | PVC pipe 63mm o/d PVC 6 kg/cm2 |
| 6 | PVC pipe 75 mm o/d PVC 6 kg/cm2 |
| 7 | PVC pipe 90 mm o/d PVC 6 kg/cm2 |
| 8 | PVC pipe 110 mm o/d PVC 6 kg/cm2 |
| 9 | PVC pipe 160 mm o/d PVC 6 kg/cm2 |
| 10 | Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to orginal Position. as per specifications for Manually Excavation including speicals |
| 11 | PVC pipe 63mm o/d |
| 12 | PVC pipe 75mm o/d |
| 13 | PVC pipe 90 mm o/d |
| 14 | Hand boring Horizontly for crossing of pipe under road or any other obstacle by using Auger/Bocki method.Including excavation stringing and jointing of pipe upto 160mm complete |
| 15 | Dismantling of Interlocking Tile 80mm thick cement concrete Interlocking paver block as per analysis attached |
| 16 | 63 mm o/d PVC Pipe |
| 17 | 75 mm o/d PVC Pipe |
| 18 | 90 mm o/d PVC Pipe |
| 19 | Dismantling of Cement Concrete 80mm thick cement concrete 1:2:4 over 100 mm thick C.C 1:8:16 and making good the same to its original condition complete in all respects as per analysis |
| 20 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) Class PN-I-as per ISI |
| 21 | 100mm I/d Sluice Valave Flanged |
| 22 | 150mm I/d Sluice Valave Flanged |
| 23 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. |
| 24 | Size 0.6 m. x 0.6 m. |
| 25 | Size 0.9 m. x 0.9 m. |
| 26 | Credit for old Sluice Valve |
| 27 | Providing, Laying, fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenhes to correct alignment and gradients, cutting, jointing and testing complete as per specifications including specials (Mechanical Excavation) |
| 28 | 160 mm o/d pipe of 10kgf./sqcm |
| 29 | Repair of 150mm dia delivery main (From T/w to duck foot bend) including cost of C.I. D/F pipes & specials, C.I. S.V., Non Return Valve, Double Air Valve, G.I. Pipes & specials, G.M. Peet Valve and pressure gauge etc. complete as DWSS |
| 30 | Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set capable of delivering 429 LPM against a head of 91 mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter, Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps, Kit-Kat etc. including G.I. column Pipe of IS 1239-2004 medium class size 80mm and Length 46 mtr. (in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 137Mtr Length and 4.00mm2 size as per IS694-1990 reaffirmed 2000. Including cost of Electronic over currant relay complete in all respects |
| 31 | 429 LPM, 91 MTR HEAD (Motor with Pump) |
| 32 | Panel Board |
| 33 | Cable (Size/Cost) 4.0sq.mm (56/0.3mm), 3Core |
| 34 | Column Pipe (G.I. B-Class) (80mm i/d) |
| 35 | Credit for old 10 BHP Motor |
| 36 | Credit for old 10 BHP Panel Board |
| 37 | Credit for old Column Pipe |
| 38 | Credit for old Cable |
| 39 | Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing |
| 40 | Construction of brick masonry toe wall in 1:5 cement sand mortar with depth 0.45 mtr ,C.C. 1:8:16 & 12.5 mm thick cement plaster in 1:4 on both sides and top of toe wall complete in all respects as per DWSS |
| 41 | Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4\\" x 4\\", size top 3\\" x 4\\",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects. |
| 42 | Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing |
| 43 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing |
| 44 | Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 & Analysis A-4 complete in all respects |
| 45 | Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing |
| 46 | Providing & fixing MS Sign Board as per standard size of DWSS |
| 47 | House Service ConnectionProviding proposed water connection to household upto wall with providing, laying, jointing, testing G.I. pipeline 15mm i/d (B-Class), (Above G.L.) Prov and fixing 15mm i/d MDPE pipe with specials (Below GL) including cost of specials such as Tees, Bends., Sockets, Elbow, Peet Valve, Union, Nipple and Hooks etc. including cutting making holes in wall, threading and testing in trenches in the ground and ISI 15mm i/d GM Ferrule as per IS:2692 and 3 inches i/d Clamp with C.I. Bib Cock, 15mm i/d as per IS:210 with Stainless Steel spindle of approved make. |
| 48 | Carriage of material such as Bajri & Sand upto end 0-110 KM (Qty as per Consumption Sheet attached) |
| 49 | Fine Aggrigate |
| 50 | Course Aggrigate |
| 51 | Surface dressing of ground including removing rank vegetation and nequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil. |
| 52 | Supplying and planting permanent trees in prepared pits and watering (Trees like Neem, Ashoka, Dake, Arjun etc.) (a) Sapling not less than 1.8 m Height and 2.5 cm calliper. |
| 53 | Planting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row. |
| 54 | Planting seedlings including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of seedlings at 20cm distance from plant to plant and row to row. |
| 55 | Provision for one way stand post with Khura complete in all respects |
| 56 | Cleaning of OHSR 100 KL |
| 57 | Construction of plinth protection around OHSR with masonry toe wall & inside earth filling with lead 5 kms. complete in all respect as per drawing |
| 58 | Construction of brick masonry over flow houdi of size 1.20 x 1.20 x 1.20 m for OHSR complete in all respects as per DWSS |
| 59 | Providing & Fixing Inside & Outside Leader of OHSR |
| 60 | Repair of expansion joint including cost of material, Chain Dori, M.S. Nuts and Bolts shuttering etc. complete in all respect |
| 61 | Expansion Joint 6\\" |
| 62 | Expansion Joint 4\\" |
| 63 | Repair of Pump Chamber |
| 64 | Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc. in water works site including Bi-directional meter and inverter of suitable capaity as per guide lines issued by PEDA complete in all respects. Please Enable Macros to View BoQ information |