| 1 | Dismantling GS sheet roofing including ridges, hips,valleys, gutters wind ties etc. includingdismembering and stacking of serviceable materials and unserviceable materials separately with all liftsand upto a lead of 50 m etc.complete as per direction of the Engineer- in-charge. |
| 2 | Dismantling doors, windows and clerestorywindows (steel or wood) shutter includingchowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 3 | Of area 3 sqm and below. |
| 4 | Of area beyond 3 sqm. |
| 5 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : |
| 6 | Of sectional area 40 sq cm and below. |
| 7 | Of sectional area beyond 40 sq cm. |
| 8 | Demolishing cement concrete manually / by mechanical means including disposal of material with all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge:- |
| 9 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 10 | Demolishing brick work including stacking of serviceable materials and disposal of unserviceable materials with all lifts and upto a lead of 50m etc. complete as per direction of the Engineer- in-charge: |
| 11 | a) In cement mortar. |
| 12 | Removing mortar from brick and cleaning bricks including stacking bricks and disposal rubbish with all lifts and upto a lead of 50 m etc. complete as per direction of the Engineer- in-charge: |
| 13 | In cement mortar. |
| 14 | Dismantling old plaster or pointing, raking out joints, cleaning and preparing the surface for re-plastering or re-pointing including disposal of rubbish to the dumping ground with all leads and lifts etc.complete as per direction of the Engineer- in-charge. |
| 15 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 16 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 17 | First class brick work in foundation and plinth including cost of all materials as required complete:- |
| 18 | In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 19 | 12 mm cement plaster of mix. |
| 20 | a) In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 21 | Neat cement punning. |
| 22 | Providing and laying cement concrete 1:2:4 (1 cement: 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. complete. |
| 23 | 40 mm thick |
| 24 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shutteringAll work upto plinth level: |
| 25 | a) 1:3:6 ( 1 Cement: 3 fine sand : 6 well burnt brick aggregate 20 mm nominal size) |
| 26 | Fabricating and supplying at site of work, steel tublar trusses of M.S pipe conforming to IS specification, complete with purlin, bracing and other necessary fittings such as cleat gusset plate etc of thickness not less than 6.00 mm including applying a primming coat (two or more coats)as per direction of the Engineer - in- Charge and approved standard design. (Member used in trusses as rafter, bottom tie and purlin are of 40.00 mm dia and struts etc are of 20.00 mm dia and bottom runner are of 25.00 mm dia conforming to IS 1239 part-II /1990 light class) . One set comprising of 4(four) nos trusses with 6(six) nos. purlin and 4.00 mtr span as per approved drawing and design etc complete excluding nuts & bolts. |
| 27 | 40mm dia |
| 28 | 20mm dia |
| 29 | Providing structural steel work in single section fixed with or without connecting plate including cutting, hoisting, making holes, fixing in position and applying a priming coat of approved steel primer all complete as required.Battens of pump house |
| 30 | Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required. |
| 31 | Providing & fixing of fabricated post made of 100mm dia medium class MS pipe (9.75 kg/mtr) 3.00 mtr long fitted with 3 nos. 75×45×6 mm cleat and 2 nos. 200 ×200×10mm gusset plate at top and bottom including cutting making necessary holes in the gusset plates, welding etc. complete (excluding nuts & bolts) as per direction of the Engineer - in- Charge. |
| 32 | Providing and fixing MS bolts including nuts and washers complete as per standard design:- |
| 33 | Upto 300mm length. |
| 34 | Above 300mm length. |
| 35 | Providing and fixing MS round holding down bolts with nuts and washer platesz complete as per standard design. |
| 36 | Providing corrugated G.S. sheet roofing/walling including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 37 | Providing and fitting G.C.I sheet (0.63 mm thick) for walling including Vertical/curved surface fixed with galvanized steel J or L hooks 8 mmdiameter, bolts and nuts with bitumen and G.I limpet washers or with G.I. limpet Washers filled with white lead and including a coat of appoved steel primer and two coats of approved paint onoverlapping of sheets complete (up to any pitch in horizontal/Verticle or curved surfaces ) excluding the cost of G.S. sheet purlins raftersand trusses and including cutting to size and shape wherever required as per direction of Engineer -in-Charge. |
| 38 | a) 0.63 mm thick |
| 39 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers including a coat of approved steel primer and two coats of approved paint complete. |
| 40 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 41 | Applying priming coat: [Payment shall be made after submission of Test Certificate issued by the Manufacturer] |
| 42 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel, galvanised iron / steel work. |
| 43 | Painting with synthetic enamel paint ( two or more coats ) of required colour of approved brand and manufacture on new work to give an even shade. [Payment shall be made after submission of Test Certificate issued by the Manufacturer] |
| 44 | Painting on G.S. sheet with synthetic enamel paint ( one or more coats ) of approved brand and manufacture of required colour to give an even shade on old work including preparation of surface as required complete as per direction of the Engineer in charge:- |
| 45 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: Two or more coats on new work25x25x5 mm thick M.S. Angle |
| 46 | Applying a coat of mordant solution on G.S. sheet on new work including cost of materials required.With a solution made of 38 gms of copper acetate in litre of soft water |
| 47 | Providing and fixing 1mm thick M.S. sheet door/window with frame of 40×40×6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as requiredUsing M.S. angels 40×40×6 mm for diagonal braces. |
| 48 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. |
| 49 | a) Fixed to steel windows by welding |
| 50 | b) Fixed to openings /wooden frames with rawl plugs screws etc. |
| 51 | Hiring charge of welding set of single phase with operating staff and carrying upto the site of work including loading and unloading (both way) complete as per direction of Engineer-incharge. |
| 52 | Re-lettering with black japan paint of approved brand and manufacture on old work as required complete as per direction of the Engineer-in-charge. |
| 53 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :Local Teak Wood |
| 54 | Providing and fixing panelled / or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked bright finished / black enamelled M.S butt hinges with necessary screws excluding panelling and or glazing, which will be paid for separately but including the wooden beading of 20 × 12 mm for fixing panelling and or glazing as per direction of Engineer-In-Charge.Local Teak wood |
| 55 | 35 mm thick shutters Please Enable Macros to View BoQ information |