| 1 | Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9\\" X 43/8\\"X 2 3/4\\" including finishing, curing, etc., complete complying with standard specification - 100CFT |
| 2 | Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications |
| 3 | Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. |
| 4 | Supplying, fabricating, erecting structural steel work for roofing welD/F or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification |
| 5 | Roofing with Galvanised Coruugated Iron Sheet of 0.8mm thickness - 10 m2 |
| 6 | Supply and fixing ofAC Exhaust Fan 375mm (15”) Sweep (Light Duty) |
| 7 | Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories.12 litter (Market Rate) |
| 8 | Providing and erecting of Retro - reflectorised Cautionary, Mandatory and Informatory signs (without definition board) made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2022 and ASTM D 4956 –09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mm x 25mmx3mm Mild steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer-in-charge. High intensity Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2022. The retro - reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2022. (as per MoRT&H specification No.801 60 cm x 60 cm square |
| 9 | Supply & Installation of Air Conditioner with copper coil 1.5 TR Split Type AC Unit - 5 Star-(M-1984) ,Supply and installation of 5 KVA capacity Automatic Voltage Stabilizer with time delay relay-M-1989,Supply and laying of 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit),Supply and fixing of MS stand for fixing outdoor unit |
| 10 | 1.5 ton AC Unit - 5 Star -M-1984 |
| 11 | 5 KVA capacity AutomaticVoltage Stabilizer |
| 12 | copper pipe (Extra beyond 3 metres supplied with AC unit) |
| 13 | Supply and fixing of MS stand for fixing outdoor unit Please Enable Macros to View BoQ information |