| 1 | DSR item No.1.17 Supplying and drawing following sizes of FRLS/HFFRPVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit asrequired. |
| 2 | 3 x 1.5 sq. mm |
| 3 | DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator). |
| 4 | 4 way (4 + 12) Double door |
| 5 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing andcommissioning etc. as required. |
| 6 | Single pole |
| 7 | Single pole and neutral |
| 8 | DSR Item No.5.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. |
| 9 | DSR item No. 5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 10 | DSR item No. 15.15 Supplying and laying of following sizeDWC HDPE pipe ISImarkedalongwithallaccessorieslikesocket,bend,couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 11 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 12 | Labour charges for horizontal boring by mechanical means (hydraulic excavator)/ manual means 1 Meter below the ground level for laying of DWC Pipe including cost of 2 nos. Pit digging and refilling, disposal earth to be leveled and neatly dressed complete in all respects to entire satisfaction of the Engineer in Charge of the work. |
| 13 | DSR item No.15.16 SupplyingandlayingoffollowingsizeDWCHDPEpipeISI markedalongwithallaccessorieslikesocket,bend,couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioningandprotectivecoveringetc.,completeasrequired. |
| 14 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 15 | Fabrication, Supply & Erection of G.I. Pipe Bracket (Medium Class) I.S.I. marked of 1¼” dia 0.9 Mtr. long welded with 2.5” dia G.I. pipe 1’ long canopy with top end closed with 14 GMS sheet to avoid entry of rain water in the pole for erection of street light fittings on existing G.I pipe pole, (As per Complete Item No. 9 of the DNIT). |
| 16 | Single Arm G.I. Pipe bracket with 0.9 meter overhang |
| 17 | S/E of Cement Collar and Jn. Box at the base of the pole with the detailed specification as given below: Jn. Box Construction:Supply & fixing of OEM made junction box IP-66/67 made out of polycarbonate with glass fiber reinforced of size 210x155x90 mm (minimum) with 5 Nos. OEM made connectors/ terminal blocks.,(As per Complete Item No. 10 of the DNIT). |
| 18 | Fabrication, Supply & Erection of 5 Mtr. Long G.I. Pipe Stepped Pole made out of 2.5” dia G.I. Pipe (3.5 Mtr. bottom) and 2” dia G.I pipe (1.5 Mtr. top) of B-Class ISI marked G.I. Pipe. The length of the overlap at joint should be 6” (minimum) (The cost of which is inclusive)., (As per Complete Item No. 11 of the DNIT). |
| 19 | Supply & Fixing of OEM Made GRP Timer Feeder Pillar of size 1075x850x320mm (Apprx.) or better, Glass-Fiber Reinforced Polyester SMC with Protection class IP 54 in accordance with IEC 60529 and Used for fabrication of Feeder Pillar boxes shall be made of out of insulating,(As per Complete Item No. 12 of the DNIT). |
| 20 | item no. 8.13.3LEDStreet lightfixture, powdercoatedpressurediecast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying,installation,Testing&CommissioningofStreet lightLEDfixturepowdercoatedpressurediecast aluminiumbodywith driver as per the requirement with Driver efficiency >85%,(As per Complete Item No. 13 of the DNIT). |
| 21 | 15 Watt |
| 22 | Supply, fabrication and erection of SheetMetal Cubical Pedestal of suitable dimensions, fabricated from a framework of 50 mm × 50 mm × 6 mm thick M.S. angle iron, covered on five sides with 1.6 mm thick M.S. sheet duly welded. The front side shall be provided with a hinged door complete with locking arrangement., (As per Complete Item No. 14 of the DNIT). |
| 23 | Cubical size 750 mm X 600 mm X 350 mm |
| 24 | Supply and laying of XLPE insulated PVC sheathed, armoured, aluminum conductor cable of 1.1 KV grade conforming to IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing trench/ DWC/ RCC/ HUME/ METAL Pipe as required at site to the entire satisfaction of E.I.C.,(As per Complete Item No. 15 of the DNIT). |
| 25 | Size 10 Sq.mm 4 Core |
| 26 | Size 16 Sq.mm 4 Core Please Enable Macros to View BoQ information |