| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section, Concrete, brick work, masonry, etc. including taking out embedded portion and making good disturbed ground all as specified and as directed. |
| 2 | Demolition of barbed wire fencing all as specified and as directed. |
| 3 | Excavating in trenches, n exc. 1.5m wide & not exc.1.5m in depth, for foundation, etc.or for shafts,wells, cesspits, manholes, pier holes, etc.n exc 10Sqm on plan and n exc.1.5m in depth and getting out as in Soft / Loose soil |
| 4 | All as per item No.3 above but depth exceeding 1.5 m qnd not exc.3m complete all as specified & directed as in (b)Soft/ Loose soil |
| 5 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm deep as in soil complete as specified. |
| 6 | Removing excavated materials exc.250 m but n.exc. 500 m and depositing where directed. |
| 7 | M&L plain cement concrete 1:4:8, Type D2 ( using 40mm graded stone aggregate) as in foundation, filling & mass concrete, complete all as specified and directed |
| 8 | M&L reinforced cement concrete (Design Mix), M-25 (using 20 mm graded stone aggregate) as in foundation, including raft, footings, foundations beams,plinth beams,bases for columns etc;basement slab,under reemed piles and mass concrete, complete all as specified and directed. |
| 9 | M&L for using M-25 Design Mix RCC using 20mm agrregate as in Columns, pillars, piers, posts and struts, etc all as specified and as directed. |
| 10 | M&L reinforced cement concrete (Design Mix), M-25 (using 20 mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed. |
| 11 | M&L Brick work with old size fly ash bricks, straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and as directed. |
| 12 | M&L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for rough finished surfaces of concrete (flat), complete all as specified and directed. |
| 13 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with fair finished surfaces of concrete surface as in square, rectangular or polygonal shape, complete all as specified and directed. |
| 14 | Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. |
| 15 | M&L Fe-500D TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified & directed. |
| 16 | All as per Item No15 above, but 6mm to 8mm dia. complete all as specified & directed. |
| 17 | M&L Fe-410-W (Gde.E-250) quality -B Joist, channel, angle, or tee sections, fixed independently without connecting plates, etc. (cut to ordinary lengths i.e.. within 20 mm of the length indicated) ,complete all as specified and directed. |
| 18 | M&L two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer to steel and iron surfaces over 10cm width or girth of any description after preparation of new or previously untreated surface ,complete all as specified and directed. |
| 19 | M & L PCC Type B0 1:2:4(12.5mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for in Item 04028, watertroughs and the like including weathering, slightly rounded or chamfered angles throating, as directedand |
| 20 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM (1:6) and finishing the surface fair and even without using extra cement. |
| 21 | Prepration of newly plastered surfaces Preparation of newly plastered surface and and applying applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade camofladge pattern(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. . ( Note :- Camouflage pattern shall be approved by Engr-in-Charge) |
| 22 | S&F Super Razor punched barb tape (SRPBT) Aluminium base helix coil with and including necessary Gl fixing clips for securing complete all as specified and directed with following specifications: - (i) Dia of coil (when unstretched) -610mm (ii) No of circles-51 turns per coil (iii) Weight of each coil with hessian pack - 8.50 Kg(+0.5) (iv) Coverage per coil - 6 RM Note- Net weight of coil per Kg shall be measured for payment purpose. |
| 23 | Supply and fix (RBT) steel wire and fixed to steel member to hold concertina coil complete all as specified and as directed. |
| 24 | Excavating in post holes (or similar holes) each n exc 0.5 cum in hard /dense soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, |
| 25 | M & L for PCC 1:3:6, type C-2, using (40mm graded stone aggregate) as in foundations, Pole coping, filling and mass concrete, complete all as specified and direceted. |
| 26 | M&L for flat form work to sides of concrete pillars, posts, struts, piers, columns and stanchions and similar work vertical to batter. all as specified and as directed. |
| 27 | All as per srl item No-15 here-in-before but 5mm dia and over upto 10mm dia stirrups, spacers and binders. |
| 28 | S & F aluminium number plate 150 x 150 x 3 mm thick with machine engraved lettering filled with black enamel paint, fixed flush in RCC boundary pillar at 1.1m above ground level with welded anchor studs embedded during casting complete all as directed. |
| 29 | M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work or concrete surfaces in two layers rendering is to be finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge. |
| 30 | Manufacturing, supplying and fixing retro reflective Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm and made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. including excavation earthwork PCC 1:2:4 , and fixing complete as per drawing , specification and direction of Engineer-in-charge. |
| 31 | Excavating in trenches, n exc 1.5 m wide and exc 1.5 m but not exc 3m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil. |
| 32 | Removing excavated material to distance not exc 50 m and depositing where directed at a level not exc 1.5m above the starting point. |
| 33 | M & L for providing of fine dry river sand cushion in trenches for cable protection complete all as specified. NOTE: - Only compacted thickness will be measured and paid. |
| 34 | Supply and laying unreinforced precast concrete cable cover, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200Kg, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified. |
| 35 | Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with GI bracket made of 40 mm dia medium grade 1.5 mtr long with 02 Nos of MS clamps of size 40 mm wide 4 mm thick and 4 Nos of MS nuts,bolts 08 Nos flat washers 3mm thick& size 50 mm long 15 mm dia for each bracket including fabrication, welding complete all as specified and directed. |
| 36 | M&L for PVC junction box weather proof of min size155x210x92 mm with 5 pole terminal fixed for aluminium painted MS clamp of size 25 mm wide 4 mm thick with necessary nuts,bolts washers 1 set , including sutable entry exit connection , Model no HENSEL Cat Part No DK1600G or eq model of make specified. |
| 37 | S&F PVC insulated and shethed starannded copper conductor 1.5sqmm size 3 core round cable for street light connection from fitting connetor to the terminal box including all fixing arrangement complete all as specified and directed complete all as specified and directed. |
| 38 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10sq mm 4core complete all as specified and as directed. |
| 39 | Supply and install & commission steel tubular swaged poles complete with cast iron base plate final taper plug bolts nuts & screws, Type 410 SP 31 (9M long) incl painting with two coats of aluminium paint overa coat of red oxide primer all as specified & as directed. Note : Excavation earthwork and PCC will be measured and paid separately |
| 40 | M & L for PCC 1:2:4, type B-2, using (40mm graded stone aggregate) as in foundations, Pole coping, filling and mass concrete, complete all as specified and direceted. Please Enable Macros to View BoQ information |