| 1 | Taking out old copper cable and S&F in Copper cable of size 25 sqmm single core, 440 Volt 50 Hz,draw in PVC conduit of including taking out old cable, complete all as specified and directed.Make-Havells/Polycab/L&T |
| 2 | Taking out old copper cable and S&F in Copper cable of size 35 sqmm single core, 440 Volt 50 Hz,draw in PVC conduit not less than 25 mm including taking out old cable, complete all as specified and directed.Make-Havells/Polycab/L&T |
| 3 | Taking out old copper cable and S&F in Copper cable of size 50 sqmm single core, 440 Volt 50 Hz,draw in PVC conduit not less than 25 mm including taking out old cable, complete all as specified and directed.Make-Havells/Polycab/L&T |
| 4 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 63 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed. Make : Siemens/Legrand/L&T. |
| 5 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 100 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed. Make : Siemens/Legrand/L&T. |
| 6 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 250 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed. Make : Siemens/Legrand/L&T. |
| 7 | Taking out old UNSV MCCB and S&F in replacement of MCCB 4 pole, 400 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed. Make : Siemens/Legrand/L&T. |
| 8 | Taking out old contractor & S&F in replacement power contactor, type ML-4, 3 pole, 415V, 50Hz, 3 Phase, with auxilary contacts 2 NL&T (Cat No -SS90910) L&T /Legrand/ Seimens/ Schinider as approved by GE] |
| 9 | Taking out old contractor & S&F in replacement power contactor, type ML-6, 3 pole, 415 V, 50Hz, 3 Phase with auxilary contacts 2 NO + 2 NC complete all as specified and directed.[Make :- L&T / Legrand/ Seimens/ Schinider as approved by GE] |
| 10 | Taking out old contractor & S&F in replacement power contactor, type ML-2, 3 pole, 415 V, 50Hz, 3 Phase with auxilary contacts 2 NO + 2 NC complete including taking out all as specified and directed.[Make :- L&T / Legrand/ Seimens/ Schinider as approved by GE] |
| 11 | Taking out old contractor & S&F in replacement electronic timer for Star Delta Starter type, timing range 3-30 sec, 415 V, 50 Hz complete including taking out all as specified and directed. [Make :- L&T / Legrand/ Seimens/ Schinider as approved by GE] ] |
| 12 | S&F in replacement thermal over load relay for Star Delta Starter type, range 5-30 amp, 415 V, 50 Hz complete including taking out all as specified and directed. [Make :- L&T / Legrand/ Seimens/ Schinider as approved by GE] |
| 13 | S&F in replacement thermal over load relay for Star Delta Starter type, timing range 66-120 amp, 415 V, 50 Hz complete including taking out all as specified and directed. [Make :- L&T / Legrand/ Seimens/ Schinider as approved by GE] |
| 14 | S & F fully automatic star delta starter suitable upto 15 HP submerssible pump set ,415 Volts, 50 Hz, 3 Phase including relay, contactor ,no volt coil,on-off switch,indicators (R Y B) and electrical wiring all as specified and directed. |
| 15 | S & F fully automatic star delta starter suitable upto 60 HP submerssible pump set ,415 Volts, 50 Hz, 3 Phase including relay, contactor ,no volt coil,on-off switch,indicators (R Y B) and electrical wiring all as specified and directed. |
| 16 | S & F fully automatic star delta starter suitable for 40 HP submerssible pump set ,415 Volts, 50 Hz, 3 Phase including relay, contactor ,no volt coil,on-off switch,indicators (R Y B) and electrical wiring all as specified and directed. |
| 17 | Taking out old submersiblle cable and S&F submersible flat copper cabl e of size 10 sqmmX3 core , 220 volt , 50 Hzall specified and directed.Make-KEI/Polycab/Hevells |
| 18 | S&F in replacement DOL starter of relay range 2 to 5 amp in sheet metal enclosure type, wall mounting suitable for , 3 phase, 415 volt, 50 hz, rp, , ML over load relay all including single phase preventer fittings complete including taking out all as specified and directed.Make: Havells/L&T/ Crompton greaves as approved by GE] |
| 19 | M&L for cutting/treeming grass, buses, and cleaning complete inside area of pump house and 2 meter outside fencing including cleaning of fencing from grass /treeming carefully taking proper precautions of electric cables, pipe lines, etc including using own T&P reqd at site, etc complete all as specifed and directed. (Approx area of pump house . |
| 20 | Supply, fabrication and fixing MS chennal/ pipe fitting/barrel piece /lateral pipe as per site requirement including nut, bolt, washer, welding etc and fibre board gasket complete and making joint leak proof including including taking out dismantling old structure complete all as specified and directed. |
| 21 | M&L for welding work of size 12 mm consider one welding job including cutting, jointing and all connected accessories all specified and directed. |
| 22 | Disconnecting/ Dismentling of submersible sewage disposal pump Set assy from its foundation at various place of Dronachal sewage pump house and transporting to civil workshop for repair complete and taking back after repairing, fixing to its existing position and making all connections.Dismentling and opening of pump assy for checking out defects. Taking out shaft from pump and carrying out lathe work on shaft for checking and making straightness. Taking out of old worn out brass impeller and M&L for filling material on worn out part , grinding, poilshing and carrying out complete lathe work, refixing on shaft and check for its smooth functioning and balancing.(Parts for following items shall be paid under relevent item here-in-after under as supply). |
| 23 | (a) 45/60 KW motor |
| 24 | (b) 30 KW motor |
| 25 | (c) 22 KW motor |
| 26 | (d) 15 KW motor |
| 27 | (e ) 11 KW motor |
| 28 | (f) 2.2 KW motor |
| 29 | Taking out unserviceable spares and burnt copper binding wire complete. M&L for rewinding of Centrifugal/submersible motor / open well motorwith insulated copper winding wire including sleeves as per original company and replacement of worn out parts, including grinding & polishing of rotor sleeves and refixing, testing & transport charges complete all as specified & directed by EIC (Parts for following items shall be paid under relevent item here-in-after under as supply). |
| 30 | (a) 1 HP to 60 HP Motor |
| 31 | Supply and fix the following parts of the submersible sewage pump and motor for capacity between 45/60 KW of original company as approved by Engineer-in-charge. ( Note :- .U/S Part other than as listed below of Pump if required to be replaced to make the pump functional is to be replaced by contractor. No extra payment shall be paid to contractor.) |
| 32 | (a) Bowl bush |
| 33 | (b) Impeller |
| 34 | (c) Neck ring |
| 35 | (d) Shaft sleeve |
| 36 | (e) Pump shaft |
| 37 | (f) Coupling |
| 38 | (g) Coupling key |
| 39 | (h) Impeller key |
| 40 | (j) Stud with nuts |
| 41 | (j) Thrust bearing |
| 42 | (k) Lower housing bush |
| 43 | (l) Upper housing bush |
| 44 | (m) Water seal mechanical type |
| 45 | (n) Rotor shaft sleave |
| 46 | (o) Drain plug |
| 47 | (p) CI Bowl |
| 48 | (q) Bearing Suitable for pump set |
| 49 | (r) Rotor Shaft |
| 50 | Supply and fix the following parts of the submersible /open well pump and motor for capacity between 20 to 30 KW of original company as approved by Engineer-in-charge. ( Note :- .U/S Part other than as listed below of Pump if required to be replaced to make the pump functional is to be replaced by contractor. No extra payment shall be paid to contractor.) |
| 51 | (a) Bowl bush |
| 52 | (b) Impeller |
| 53 | (c) Neck ring |
| 54 | (d) Shaft sleeve |
| 55 | (e) Pump shaft |
| 56 | (f) Coupling |
| 57 | (g) Coupling key |
| 58 | (h) Impeller key |
| 59 | (j) Stud with nuts |
| 60 | (j) Thrust bearing |
| 61 | (k) Lower housing bush |
| 62 | (l) Upper housing bush |
| 63 | (m) Rotor shaft sleave |
| 64 | (n) Drain plug |
| 65 | (o) Water seal |
| 66 | (p) CI Bowl |
| 67 | (q) Rotor Shaft |
| 68 | (r) Bearing Suitable for Existing Pump |
| 69 | Supply and fix the following parts of the centrigual Pump and motor for capacity 2 to 15 KW of original company as approved by Engineer-in-charge. ( Note :- .U/S Part other than as listed below of Pump if required to be replaced to make the pump functional is to be replaced by contractor. No extra payment shall be paid to contractor.) |
| 70 | (a) Bowl bush |
| 71 | (b) Impeller |
| 72 | (c) Neck ring |
| 73 | (d) Shaft sleeve |
| 74 | (e) Pump shaft |
| 75 | (f) Coupling |
| 76 | (g) Coupling key |
| 77 | (h) Impeller key |
| 78 | (j) Stud with nuts |
| 79 | (k) Thrust bearing |
| 80 | (l) Lower housing bush |
| 81 | (m) Upper housing bush |
| 82 | (n) Rotor shaft sleave |
| 83 | (o) Drain plug |
| 84 | (p) Water seal |
| 85 | (q) CI Bowl |
| 86 | (r) Rotor Shaft |
| 87 | (s) Bearing Suitable for Existing Pump |
| 88 | S&F in replacement to ON load Changeover Switch,Rotory type 100 Amp,415 Volt , TPN, front operated with out sheet metal enclosure suitable for mounting on existing panel as per sample and site requirement complete all as specified and directed Make-HPL/Havells/L&T |
| 89 | S&F in replacement to ON load Changeover Switch,Rotory type 200 Amp,415 Volt , TPN, front operated with out sheet metal enclosure suitable for mounting on existing panel as per sample and site requirement complete all as specified and directed Make-HPL/Havells/L&T |
| 90 | S&F in replacement to ON load Changeover Switch,Rotory type 250 Amp,415 Volt , TPN, front operated with out sheet metal enclosure suitable for mounting on existing panel as per sample and site requirement complete all as specified and directed Make-HPL/Havells/L&T |
| 91 | S& F Bldg Security light 45 watt IP 65 Protection with clamp and braket size 50 mm medium class GI tubing complete with wiring all as specfied and directed. Please Enable Macros to View BoQ information |
| 92 | S& F Bldg Security light 45 watt IP 65 Protection with clamp and braket size 50 mm medium class GI tubing complete with wiring all as specfied and directed. Please Enable Macros to View BoQ information |