| 1 | Demolition of floor hearth or wall tiling including cement mortar bedding but not backing and removing rubbish/ demolished material off the premises complete all as specified and directed. |
| 2 | M&L for vitrified ceramic tiles 10mm thick in light/dark shade (square/rectangular) area of each tile not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed with white or colour cement to match the surface.over screed bed or bedding layer 15mm thick in cement mortar 1:6 complete all as specified and directed. |
| 3 | All as per BOQ srl item No 2.00 here-in-above but as in skirting including 10mm thick in CM 1:4 rendering as in backing coat complete all as specified and directed. |
| 4 | M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) jointless area of each tile exceeding 0.11 but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed with white or colour cement to match the surface.over screed bed or bedding layer 15mm thick in cement mortar 1:6 complete all as specified and directed. |
| 5 | M&L for coloured glazed designer ceramic tiles 300 x 450 x 7 to 8mm thick on vertical surface as in dado/skirting and jointed in neat cement slurry and pointed with white/colour cement to match with the surface over 15mm thick rendering in CM 1:4 complete all as specified and directed. |
| 6 | S&F in repair aluminium alloy door closer hydraulically regulated , designation No 2 universal type, suitable for door shutter of 701 to 850mm in width and weight between 36 to 60 Kg and fixed to door frame complete all as specified and directed. . |
| 7 | S&F 5 mm thick plain colour PVC sheet hollow interlocking wall panelling of width 250 mm for wall panelling inclusive of fixing on wall with screws and solvent alongwith PVC 'U' and 'L' beading at corner and end portion where ever required of matching colour including taking down of existing wall lining, board or insulation board/panelling including cover fillets of any type and thick complete all as specified and as directed.NOTE : - Unit rate quoted against this item shall also includes taking down and refixing the same of any electrical board, switch, sockets, light and fittings, fans etc after carrying out necessary relevant work and making good to match with existing surface effected for this area etc complete all as specified and directed. |
| 8 | Taking down Chowkats With shutters(without taking of shutters from the frames) or frames exceeding 1.5 Sqm but not exceeding 4 sqm including dismantling of brick work for hold fast complete all as specified and as directed. |
| 9 | Taking down Chowkats With shutters(without taking of shutters from the frames) or frames not exceeding 1.5 Sqm including dismantling of brick work for hold fast complete all as specified and as directed |
| 10 | S&F anodised podwer coated aluminium door made out hollow aluminium section as mentioned below. Each door having 02 Nos disk or D type handle of 200 mm long , two Nos aluminium tower bolts of 200 size , one No mortice lock of six levers with key in duplicate regulated by double action hudrolic floor door spring (Make - Sandhu/Titz) shutters to be partly glazed with 5mm thick tinted glass and partly panelled with 12mm thick prelaminated particle board fixed with glazing clips, rubber beading/gasket anodised aluminium beading screws etc complete all as specified and as directed. Make :- Anodised aluminium section : HINDALCO/JINDAL/INDALCOGlass : SAINT GOBAIN/MODI GUARD/TATACHOWKHATS SIZE : 100 X 44 X 1.60 MM THICK SHUTTERS VERTICLE STYLE : 100 X 44 X 1.60MM SHUTTERS LOCK RAIL : 150 X 44 X 1.60MM SHUTTERS BOTTOM RAIL : 200 X 44 X 1.60MM |
| 11 | S&F in repair anodised aluminium partition wall or fixed type window/ventilator made out of aluminium anodised standard hollow section 100 x 44 x 1.60mm thick snap fit beading standartd rubber gasket 5.5mm thick glass or 12mm thick prelaminated particle board interior grade prelaminated one side with decorative choice laminates and other side balancing light grey lamination etc complete all as specified and as directed. |
| 12 | S&F three track with two or more shutter with 4mm thick tinted glass, one shutter of Stainless steel wire cloth 0.36mm nominal dia & 1.18 mm width aperture for mosquito proofing with good quality bearing , handle lock , rubber beading and glazing clips etc using following aluminium powder coated section conforming to following catalogue of 'JINDAL' or of equivalent make as mentioned in list of makes here-in-after complete all as specified and as directed by Engr-In-Charge(a) Bottom frame 20620 (b) Top frame & vertcal 20621 (c) Handle (side) 20606 (d) Shutter Interlock 20724 (e) Shutter Top & bottom 20844 (f) Glazing clip 19352 |
| 13 | S&F in repair Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. |
| 14 | S&F fully perforated false ceiling 12 mm thick with micro tegular edged at all height with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and pattern having moisutre content less than 2%, humidity resistance of 99%, NRC 0.60 to 0.85 as per IS 8225-1987, non combustible as per BS 476 (Part-4) 1970 and light code description unit code No 429 Sub Head 26. New Technologies and materials reflectance of 85% minimum to be laid in true horizontal level suspended on interlocking metal T -grid of hot dipped galvanised iron section of 0.33 mm thick ( galvanised @ 120 gms/ sqm including both sides) comprising of main T- runners of size 15x 32mm of length 3000mm, cross T of size 15 x32 mm of length 1200mm and secondary intermediate cross T of size 15 x 32 mm of length 600 mm to from grid module of size 600 x 600 mm, suspended form ceiliing using galvanised mild steel items (Galvanised @ 80 gm/sqm) i.e. 50 mm long, 8mm outer diameter M-6 dash fastners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85 x 25 x 2mm. galvanised iron perimeter wall angle of size 24 x 24 x 0.4 mm of length 3000 mm to be fixed on perimeter wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40 mm long dry wall SS screws including taking down old ceiling board. The work shall be carried out as per specification, drawing and as per direction of the Engineer-in-Charge.NOTE : -Unit rate quoted against this item shall also includes taking down and refixing the same of any electrical board, switch, sockets, light and fittings, fans etc after carrying out necessary relevant work and making good to match with existing surface effected for this area etc complete all as specified and directed. |
| 15 | M&L for preparation of old or previously treated surfaces of RCC / Stone / Concrete / brick walls/ Asbestos Cement Sheet or plastered surfaces and applying one coat of exterior acrylic emulsion paint in camouflaging pattern of any shape and any size complete all as specified and directed by Engineer-in-charge, Note: (i) Sample of camouflaging pattern to be approved by GE as per user requirement. Pattern to be followed, will be given by the user. |
| 16 | M&L for preparation of plastered or unplastered surfaces of walls and applying one coats of distemper oil emulsion on old surfaces upto any height including necessary scaffolding as required, complete all as specified and directed. |
| 17 | M&L for one coat of synthetic enamel paint on old painted steel surfaces as in walls / roof trusses/purlins/rafters/angle iron posts etc complete all as specified and directed. |
| 18 | M&L for complete removal of existing treatment from old decorated plastered surface of wall and applying two coats of distemper oil emulsion complete all as specified and directed. |
| 19 | M&L for preparation of old or previously treated surfaces of RCC / Stone / Concrete / brick walls/ Asbestos Cement Sheet or plastered surfaces and applying two coat of exterior acrylic emulsion paint in camouflaging pattern of any shape and any size complete all as specified and directed by Engineer-in-charge, Note: (i) Sample of camouflaging pattern to be approved by GE/ as per user requirement. Pattern to be followed, will be given by the user. |
| 20 | M&L for one coats of painting as per manufacturer instruction to PCC pavements or concrete surface of Runway / taxi tracks and the like exceeding 10 cm wide with Water proof of any shade as approved by Engineer-in-Charge including cleaning all foreign materials, dust etc by water or air blower and scrapers complete all as specified and directed by Engineer-in-Charge. |
| 21 | Demolition of brick work built in CM or cement lime mortar complete all as specified and directed. |
| 22 | M&L for bricks work built in CM mortar 1:6 with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 23 | M&L for rendering 15mm thick on any faces of brick wall or concrete surface in CM 1:4 mixed with WPC @ 3% by weight of cement finished fair and even without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separetely. |
| 24 | Supply only integral water proofing compound complete all as specified and directed. |
| 25 | M&L for cleaning and removing all scale and dirt, etc from PVC tanks exceeding 250 litre but not exceeding 500 litre capacity tanks from mouths of circulating pipes, etc complete all as specified and directed. |
| 26 | M&L for waterproofing of Roof sheet with liquid applied PU liquid membrane alongwith 1.5 mm thick bituminous membrance system applied by liquid rubberized adhesive and UV paint complete all as specified and as directed by Engineer-in-Charge |
| 27 | M&L for oiling & greasing of bottom wheels, top wheels, bottom rails, top guide rails of shutters including necessary scaffolding complete all as specified and directed. |
| 28 | Dismantling of mild steel work or wrought iron of any description in any position complete all as specified and directed. |
| 29 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed |
| 30 | M&L for preparation of new steel surfaces exceeding 10 cm girth and apply two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed. |
| 31 | Dismantling of plain or corrugated steel sheeting any guage , thickness, including Nainital or similar pattern from roof covering complete all as specified and directed. |
| 32 | S&F pre painted galvalume zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws as specified complete all as specified and as directed. |
| 33 | Excavation in post holes each not exceeding 0.5cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm watering and removing surplus soil to a distance exceeding 50m and making good surface in soft/loose soil, complete all as specified and directed |
| 34 | M&L for PCC (1:3:6) type C-2 using 40 mm graded mechanically crushed stone aggregate in foundation mass concrete and filling complete all as specified and directed Please Enable Macros to View BoQ information |