| 1 | Material and Labour for disconnection of elctrical connections from terminal box of monoblock pumpset of capacity 3 phase, 60/100 HP, dismantling of existing pipe line connections, decoupling pump/motor from pumpset, removing/lifting from foundation bed using chain pulley including transporting to authorized work shop/work site after repairs (if required) and re-fixing of motor/pump on foundation after repairs, re-coupling with motor/pump, re-connection of existing pipes electrical connections, testing complete all as specified and as directed |
| 2 | Material and Labour for disconnection of elctrical connections from terminal box of monoblock pumpset of capacity 3 phase,10/12.5 HP, ismantling of existing pipe line connectionsremoving/lifting from foundation bed including transporting to authorized work shop/work site after repairs (if required) and re-fixing of pumpset on foundation after repairs, re-connection of electrical connections, testing complete all as specified and as directed |
| 3 | All as per serial Item No.2 here in before but of capacity 5/7.5 HP complete all as specified and as directed |
| 4 | All as per serial Item No.2 here in before but of capacity 1/3 HP complete all as specified and as directed |
| 5 | Material and Labour for disconnection of elctrical connections of horizontal submersible pumpset of capacity 3 phase, 5/7.5/10 HP including drain out of sump, dismantling existing pipe connections, lifting pumpset form open well/sump including transporting to authorized work shop/work site after repairs and lowering of pumpset in well/sump, hanging at certain depth with new rope, re-connection with existing pipe line and of electrical connections after repairs, testing complete all as specified and as directed |
| 6 | All as per serial Item No.5 here in before but of capacity single phase, 1 HP complete all as specified and as directed |
| 7 | Material and Labour for disconnection of elctrical connections of vertical multistage submersible pumpset of capacity 3 phase, 3/5 HP, lifting pumpset from borewell of depth upto 100 ft, dismantling existing pipe connections including transporting to authorized work shop/work site after repairs (if required) and re-connection with existing pipe line and of electrical connections after repairs, lowering to original depth, testing complete all as specified and as directed |
| 8 | Material and Labour for Rewinding of Kirlsokar make electric motor 3 phase, 60 HP including dismantling motor stator and taking down burnt out/weak insulation winding/fibre strip/insulated materials, cleaning of stator slots by CTC solution and rewinding on stator slots with dual coat super enamelled copper wire of existing gauge with materials/fibre strip/varnishing and made terminal connection using 90 mm fibre glass coated wire, assembling the motor complete all as specified and directed |
| 9 | Material and Labour for replacement of 60 HP electric motor unserviceable bearings (Load end and free end) including dismantling of rotor from motor casing, taking out unserviceable bearings using bearing pullar, replacement of load end and free end bearings, assembling complete motor casing after repairs complete all as specified and directed |
| 10 | Material and Labour for replacement of unserviceable DE and NDE roller bearing of 60HP pump including dismantle impeler shaft from pump and DE, NDE bearings using bearing pullar, pressing new DE, NDE bearings, re-fixing of gland seal and impeller shaft in pump casing complete all as specified and directed |
| 11 | Material and Labour for Dismantle of 100HP pump split case to replace the broken impeller shaft as same size as existing, gland set, brass collar ring,gland sealing stain less steel sleeve for each side of pump shaft,coupling set,gland flange etc. Re-assemble the repaired impeller shaft in pump split case complete all as specified and directed |
| 12 | Material and Labour for replacement of pump-motor coupling rubber bush of model SW 280 for following capacity pumpset |
| 13 | a) 100 HP pumpset |
| 14 | b) 60 HP pumpset |
| 15 | Material and Labour for Rewinding of 3 Phase, monoblock pumpset of following capacity including dismantling winding stator from pumpset, taking down burnt out/weak insulation winding/fibre strip/insulated materials, cleaning of stator slots by CTC solution and rewinding on stator slots with dual coat super enamelled copper wire of existing gauge with materials/fibre strip/varnishing and made terminal connection using fibre glass coated wire, assembling pumpset complete all as specified and directed |
| 16 | a) 12.5 HP pumpset |
| 17 | b) 10 HP pumpset |
| 18 | c) 7.5 HP pumpset |
| 19 | d) 5 HP pumpset |
| 20 | e) 3 HP pumpset |
| 21 | Material and Labour for replacement of bearings of 3 phase monoblock pumpset including unserviceable bearings including dismantling of impeller shaft/bearing shaft from pumpset, taking out unserviceable bearings using bearing pullar, replacement of bearings, assembling complete pumpset after repairs complete all as specified and directed |
| 22 | a) 12.5 HP pumpset |
| 23 | b) 10 HP pumpset |
| 24 | c) 7.5 HP pumpset |
| 25 | d) 5 HP pumpset |
| 26 | e) 3 HP pumpset |
| 27 | All as per Seial Item No.13 here-in-before but of single phase, monoblock pumpset of capacity 1 HP complete all as specified and as directed |
| 28 | All as per Serial Item No.14 here-in-before but of single phase, monoblock pumpset of capacity 1 HP complete all as specified and as directed |
| 29 | Material and Labour for Rewinding of 3 Phase, horizontal submersible pumpset of following capacity including dismantling winding stator from pumpset, taking down burnt out/weak insulation winding/fibre strip/insulated materials, cleaning of stator slots by CTC solution and rewinding on stator slots with dual coat super enamelled copper wire of existing gauge with materials/fibre strip/varnishing and made terminal connection using fibre glass coated wire, replacement of bush, assembling pumpset complete all as specified and directed |
| 30 | a) 10 HP submersible pumpset |
| 31 | b) 7.5 HP submersible pumpset |
| 32 | c) 5 HP submersible pumpset |
| 33 | d) 3 HP submersible pumpset |
| 34 | Material and Labour for Rewinding of 3 Phase, vertical multistage submersible pumpset of following capacity including dismantling winding stator from pumpset, taking down burnt out/weak insulation winding/fibre strip/insulated materials, cleaning of stator slots by CTC solution and rewinding on stator slots with dual coat super enamelled copper wire of existing gauge with materials/fibre strip/varnishing and made terminal connection using fibre glass coated wire, replacement of end ring, assembling pumpset complete all as specified and directed |
| 35 | a) 5 HP submersible pumpset |
| 36 | b) 3 HP submersible pumpset |
| 37 | All as per serial Item No.17 here-in-before but of single phase, 1 HP submersible pumpset complete all as specified and as directed |
| 38 | Supply and Fix in replacement of old u/s 3 pole power contactor type MNX 250, AC 1 rating 160 Amps and AC3 rating 140 Amps Aux contacts 2 NO+2NC range from 9A-650 A, 240 V coil voltage including taking down the existing unserviceable material complete all as specified and directed |
| 39 | Supply and Fix in replacement of old u/s 3 pole power contactor type MNX 140, AC 1 - 300 Amps, AC3 - 250 Amps, Aux contacts 2 NO+2NC range from 9A-650 A, 240 V coil voltage including taking down the existing unserviceable material complete all as specified and directed |
| 40 | Supply and Fix in replacement of old u/s 3 pole power contactor type MNX110, AC 1 rating 160 Amps and AC3 rating 110 Amps Aux contacts 2 NO+2NC range from 9A-650 A ,240 V coil voltage including taking down the existing unserviceable material complete all as specified and directed |
| 41 | Supply and Fix in replacement of old u/s 3 pole power contactor type ML-4 ,AC 1 rating 100 Amps and AC3 rating 70 Amps Aux contacts 2 NO+2NC range from 25-300 A ,240V coil voltage including taking down the existing unserviceable material complete all as specified and directed |
| 42 | Supply and Fix in replacement ML-4 FASD starter coil, voltage of 230V complete all as specified and as directed |
| 43 | Supply and Fix in replacement ML-4 FASD starter contactor kit complete all as specified and as directed |
| 44 | Supply and Fix in replacement of old u/s DOL starter (Direct on line) 1 phase 230 Volts 50 Hz relay range 06 to 10 Amps including taking down old material complete all as specified and directed TYPE: MU2P |
| 45 | Supply and Fix in replacement of old u/s DOL starter (Direct on line) 3 phase 415 Volts 50 Hz relay range 6-10A/9-14A including taking down old material complete all as specified and directed TYPE: MK1 |
| 46 | Supply and Fix in replacement FASD (Fully Automatic Star Delta starter) 3 phase 415 Volts 50 Hz relay range 9-14A including taking down old material complete all as specified and directed TYPE: MK1 |
| 47 | All as per Item No.28 here in before but relay range of 13-22A complete all as specified and as directed TYPE: MK1 |
| 48 | Supply and Fix in replacement of following spares parts including taking down unserviceable suitable for MK1 type starter sets |
| 49 | a)Push button unit (1 green + 1 red) |
| 50 | b)Aux contact block (1 NO + 1 NC) |
| 51 | c)Thermal timer without combination coil |
| 52 | d)MK1 contactor, 440V |
| 53 | e) MK1 thermal overload relay 6-10A/9-14A |
| 54 | f) MK1 thermal overload relay 13-22A |
| 55 | Supply and Fix in replacement DOL submersible pump controller in sheet enclosure type MU-G motor rating AC-3 duty ,415 volt 50 Hz, 3 phase relay range 6-10 Amps for Submersible motor complete all as specified and directed |
| 56 | Supply and Fix in replacement DOL submersible pump controller in sheet enclosure type MU-G motor rating AC-3 duty ,415 volt 50 Hz, 3 phase relay range 9-14 Amps for Submersible motor complete all as specified and directed |
| 57 | Supply and Fix in replacement FASD submersible pump controller in sheet enclosure type MU-G motor rating AC-3 duty ,415 volt 50 Hz, 3 phase relay range 13-21 Amps for Submersible motor complete all as specified and directed |
| 58 | Supply and Fix in replacement of old u/s electronic star Delta timer, wide operating voltage 160-500V, 50 Hz available in time delay range3-30sec and 12-120 secs including taking down old material complete all as specified and directed |
| 59 | Supply and Fix in replacement of old u/s electronic type single phase preventer 415 V ,50 Hz including taking down old material complete all as specified and directed |
| 60 | Supply and Fix in replacement of old u/s LED indication lamp (Red/Yellow/Blue/ Green) of panel mounting type including taking down old material complete all as specified and directed |
| 61 | Supply and Fix in replacement of old u/s flat submersible 3 core copper conductor PVC insulated and PVC sheathed cable of size 6 Sqmm including taking down old unserviceable Material complete all as specified and directed |
| 62 | All as per Serial Item No. 37 here-in-before but 3 core 4 sqmm |
| 63 | All as per Serial Item No. 37 here-in-before but 3 core 2.5 sqmm |
| 64 | Supply and Fix in replacement of old u/s PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 3 core x 2.5 sqmm including taking down old unserviceable Material complete all as specified and directed |
| 65 | Supply and Fix in replacement MCB, 415V, 10kA 'C' curve, TP 25-63A in the panels complete all as specified and directed |
| 66 | Supply and Fix in replacement MCB, 415V, 10kA 'C' curve, TPN 40-100A in the panels complete all as specified and directed |
| 67 | Supply and Fix in replacement MCB, 230V, 10kA 'C' curve, SP 6-32A in the panels complete all as specified and directed |
| 68 | Supply and Fix in replacement MCB, 230V, 10kA 'C' curve, DP 6-32A in the panels complete all as specified and directed |
| 69 | Supply and Fix in replacement of old u/s MCCBs 415V, 16 KA, 4 Pole,63A-100A variable thermal setting complete all as specified and directed. |
| 70 | Supply and Fix in replacement of old u/s MCCBs 415V, 25 KA, 4 Pole, 125-160A variable thermal setting complete all as specified and directed. |
| 71 | Supply and Fix in replacement of old u/s MCCBs 415V, 25 KA, 4 Pole, 160A-200A variable thermal setting complete all as specified and directed. |
| 72 | Supply and Fix in replacement of old u/s Cast Iron foot valve 100 mm dia complete all as specified and directed |
| 73 | All as per serial item No.48 here-in-before above but 80mm |
| 74 | All as per serial item No.48 here-in-before but 65mm |
| 75 | All as per serial item No.48 here-in-before but 50mm |
| 76 | All as per serial item No.48 here-in-before but 25mm |
| 77 | Supply and Fix in replacement of old u/s spare cylindrical condenser with wire of 30 micro farad capacity including taking down old material complete all as specified and directed. |
| 78 | All as per serial item No.53 here-in-before but 20 micro farad capacity |
| 79 | Supply and Fix in replacement of analog volt-ammeter in exisitng LT panels including taking down old unserviceable complete all as specified and as directed. |
| 80 | Material and Labour for servicing of 60 to 100 HP, 3 phase monoblock pumpsets by tightning of nuts and bolts, removal of scaling on shaft, base by sand paper, greasing as required, replacement of worn out gland ropes of suitable gauge, Checking health of winding, pump including greasing as required complete all as specified and as directed |
| 81 | All as per serial item No.56 here-in-before but of capacity 5 to 12.5 HP |
| 82 | All as per serial item No.56 here-in-before but of capacity 1 to 3 HP of any type |
| 83 | Material and Labour for Scraping the old paint by using wire brush and emery paper and preparation of the surface for painting the following pump set's /control panel /suction and delivery pipe of the pump house with one coat of primer and two coat of synthetic enamel paint all as specified and directed at site of the following items of Water supply installations:- |
| 84 | (a) 100 HP Pumpsets |
| 85 | (b) 60 HP Pumpsets |
| 86 | (c) 12.5HP Pumpsets |
| 87 | (d) 10HP Pumpsets |
| 88 | (e) 7.5HP Pumpsets |
| 89 | (f) 5HP Pumpsets |
| 90 | (g) 01 HP pump |
| 91 | (h) LT Panels & starter panels |
| 92 | (j) Suction /Discharge CI/DI/MS pipe 250mm/200mm/150mm pipe line |
| 93 | Supply and Fix in repairs CPVC pipes SDR-11 with all fittings on wall/foundation complete all as specified of the following sizes of pipes |
| 94 | (a) 25mm bore |
| 95 | (b) 50mm bore |
| 96 | Supply and Fix in replacement of CPVC pipes Sch-80 with all fittings except flanges on wall/foundation complete all as specified including taking out the unserviceable of the following sizes of pipes |
| 97 | (a) 65mm bore |
| 98 | (b) 80mm bore Please Enable Macros to View BoQ information |