| Sl. No. | Item Description |
| 1 | Dismanling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 2 | S & F steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to I.S.1161- 1979 Fe 410-W (GdeE- 250) complete all as specified and as directed by Engineer-In-charge |
| 3 | S & F rolled mild steel in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. Within 20mm of the length indicated)conforming to Fe 410 -W (Gde- E- 250) quality-A complete all as specified. |
| 4 | M & L for preparation of new steel surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of red oxide all as specified and directed. |
| 5 | M & L for preparation of old steel surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of red oxide all as specified and directed. |
| 6 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings complete all as specified and directed |
| 7 | S&F Pre-painting galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed |
| 8 | S&F Pre-painting galvatume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed |
| 9 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness inclduding cover fillets. |
| 10 | Dismantling timber scantlings 40 sq.cm and over in section, in any positions as in framed work. |
| 11 | -Ditto- all as per item above but in fillets, rails, posts, rafters, purlins, etc under 40 sq.cm in section. |
| 12 | M & L for 6mm thick (No of ply 5) plywood, grade BWR, type BB, fixed with nails to timber frame work as in ceiling complete all as specified and directed. |
| 13 | M & L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 3 & n.exc 6 sq.cm complete all as specified and directed. |
| 14 | M & L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 13 & n.exc 25 sq.cm complete all as specified and directed. |
| 15 | M & L for second class hardwood clean sawn scantlings as in timber framed and fixed complete all as specified and directed. |
| 16 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and directed. |
| 17 | M &L for pre-cast cement concrete type C1 1:3:6 using 20mm graded stone aggregate as in block masonry with solid blocks, exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 18 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc. |
| 19 | M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:4 using WPC 3% by weight of cement (WPC to be measured and paid separately) and finished even and smooth (without using extra cement). |
| 20 | M & L for rendering 10mm thick on fair faces of brick or concrete surfaces in cement plaster 1:6 and finished even and smooth (without using extra cement). |
| 21 | M & L for preparation of new plastered surface of wall and applying two coats of distemper oil emulsion over a coat of chalk whiting as a preparatory to distempering complete all as specified and directed. |
| 22 | M & L for preparing newly plastered or previously untreated walls surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed. |
| 23 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 24 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed. |
| 25 | M &L 75mm thick cement concrete type D2 1:4:8 in sub base floor complete all as specified and directed. |
| 26 | M &L 75mm thick cement concrete type C2 1:3:6 using 40mm graded stone aggregate finishing surface even and smooth wuthout using extra cement a in plinth protection all as specified and directed. |
| 27 | M &L chequered cement concrete tile 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry over 20mm thick scrred bed in cement mortar 1 :4 as in floors with grey cement and pigment complete all as specified and directed. |
| 28 | M & L for non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceding 0.18 sqm but not exceeding 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:6. |
| 29 | M & L for vitrified ceramic tiles light shade 10mm thick but not exceeding 0.36 sqm, in dado/ skirting in verticle surfaces etc floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed in cement mortar 1:4 etc set and jointed in neat cement slurry and pointed in coloured cement to match the surface of tile completed all as specified and directed by E-in-Charge. |
| 30 | M & L for glazed ceramic coloured tiles in vertical surface 300 x 200 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick screed bed in cement mortar 1:4. |
| 31 | Taking down chowkats or frames not exc 1.5 sq.m each but with shutters (without taking off shutters from the frames). |
| 32 | Taking down chowkats or frames exc 1.5 sq.m but n.exc 4 sq.m each but with shutters (without taking off shutters from the frames). |
| 33 | S & F second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints. |
| 34 | S & F of 35 mm thick (Batten thickness) 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, with plain, chamfered or rounded, mitered and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule part – I (Specifications - 2009) complete all as specified and directed. |
| 35 | S & F of 30 mm thick (Batten thickness) 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, with plain, chamfered or rounded, mitered and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule part – I (Specifications - 2009) complete all as specified and directed. |
| 36 | S & F clamps, hold fast,hook washer & similar small articles conforming to Fe-290 Gde-E-165. |
| 37 | M & L for providing cement concrete type C1 1:3:6 using 20mm graded stone aggregate as in hold fast blocks. |
| 38 | S & F 125mm butt hinges, medium weight, cold rolled mild steel and fixed. |
| 39 | -Ditto- all as per item above but 75mm long. |
| 40 | S & F 300mm length aluminium alloy, anodised, sliding door bolt hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed. |
| 41 | S & F 150mm Aluminium handles, cast type, anodised |
| 42 | S & F 125mm Aluminium handles, cast type, anodised |
| 43 | S & F 150mm aluminium, anodised, barrel tower bolts of extruded section and fixed. |
| 44 | S & F 125mm aluminium, anodised, barrel tower bolts of extruded section and fixed. |
| 45 | S & F mild steel 300mm ordinary rat tail rod pattern springs, including roller and roller plate complete. |
| 46 | M & L sheet glass, 4mm thick ordinary quality and glazing with oil putty or beadings in square not exc 0.5 sqm in each pane. |
| 47 | S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples all as specified and directed. |
| 48 | M & L for preparation of new wooden surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed. |
| 49 | S & F in repairs Harrison Curtain rails, mild steel, chromium plated with fixing brackets, stops, rollers etc.complete all as specified and directed. |
| 50 | S& F for providing and fixing powder coated aluminium (minimum thickness of powder coated 50 micron) work for doors, windows, ventilator and partitions (Fixed portion) with extruded build up statndard tubular sections/ appropriate Z sectins and other sections of approved make conforming to IS : 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at jucntions, i.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. aluminium section shall be smooth, rust free, straight, snap beading for glazing/panelling, CP brass/stainless steel screws, all complete aand directed |
| 51 | S&F anodised aluminium door shutters, aluminium section weighing 0.55Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and directed |
| 52 | M&L for prelaminated particle board, 9mm thic, exterior grade, prelaminated both sides with decorative choice lamination complete all as specified and directed |
| 53 | M&L sheet glass 4.80mm thickness , ordinary quality and glazing with oil putty in square exc 0.5 Sqm in each pane complete all as specified and directed |
| 54 | M&L in repairs 18/19mm thick particle board, medium density, flat pressed single line layer type or three layer type with BWR type adhesive fixed with nails to timber frame including dismantling existing board complete all as specified and directed.Make-Century |
| 55 | S&Fin repair Vitreous China, pedestal pattern white including trap set with concrete including Seat and cover,10ltrs low level fluslhing cistern with flush pipe complete all as specified and directed by engr-in-charge. |
| 56 | S & F in repairs for Wash Hand basins, Vitreous China, white, flat back, size 550x440mm, including cutting for and pinning in ends of brackets or erecting stand, angle bracket (but exclusive of fixing of supply, waste pipe, taps) complete all as specified and directed. |
| 57 | S&F in repair bib taps 15mm dia fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed. complete all as specified and directed by Engr In Charge. |
| 58 | S&F in repair Angle stop valve of PTMT any colour pressure screwed for iron pipe and fixed (15mm minimum weight 90 Gms) 15mm dia fixed to iron pipe. |
| 59 | Supply & fixing in repair 15mm pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down , high pressure, with or without lettered 'Hot' or Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed. Bore of pipe in 15mm complete all as specified and directed by Engr In Charge.. |
| 60 | S&F for waste coupling of PTMT for 32 mm bore dia of discharge pipe (half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms) |
| 61 | S&F PVC connections 15mm size with PTMT nuts of length 600mm |
| 62 | S&F cast iron floor trap 75mm out let dia with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4).. |
| 63 | M & L for Gully traps salt glazed stoneware (SGSW) square or round mouthed type 'P' of size 180x100mm for drain pipes complete all as specified and directed. |
| 64 | Taking up or down 15mm bore steel water tubing & connections, incl cleaning for existing or offrening credit as per sch of credit all as directed. |
| 65 | S&F 15mm bore galvanised steel tubes, 'medium grade' with all fitting and fixed complete to walls and ceiling or laid in floors completed all as specified and directed by E-in-Charge |
| 66 | S & F 75 mm dia bore PVC (SWR) pipes single socketed , in any length with rubber ring joints , laid in tenches or in floors |
| 67 | S & F 110 mm dia bore PVC (SWR) pipes single socketed , in any length with rubber ring joints , laid in tenches or in floors |
| 68 | S&F in repairs sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe,overall size 495mm x 420mm bowlsize 410mm x 330mm x 160mm completed all as specified and directed by E-in-Charge |
| 69 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed by Engr-in-Charge |
| 70 | Taking down unserviceable submain wiring and service cable alongwith batten /PVC conduits etc. and making good disturbed surfaces of walls/floors and match the existing surface all as directed at site. |
| 71 | Taking down unserviceable main switches, DBs with MCB SP/Isolators by unscrewing form board complete all as specified and directed by Engineer-in-Charge |
| 72 | Matrial & Labour for point wiring using approved colour coding as per IS with using approved coper coding as per IS 1.5 Sqmm multistranded , 1100 volt grade copper conductor FRLS cable of PVC insulated and unsheathed type alongwith 1.5 Sqmm PVC insulated stranded copper conductor cable for continuous earthing in & incl PVC casing & caping with accessories having ISI mark fixed on wall surfaces / ceiling including provision PCV Box on top for fixing switches sockets etc. all as specified for one light point / fan / Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 73 | All as per Srl item No 72 here-in-before but controlled with one 3 pin socket outlet 5 Amp on the same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 74 | All as per Srl item No 72 here-in-before but controlled with one 3 pin socket outlet 5 Amp on the independent board with cable 1.5sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 75 | All as per Srl item No 72 here-in-before but controlled with one 3 pin socket outlet 15 Amp, independent board with cable 2.5sqmm including provision of 2.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 76 | Supply and fixing of switch piano type 5 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 77 | Supply and fixing of socket outlet 3 pin 5 Amp 2-in-one 230 Volt flush type complete all as specified and directed by Engineer -in-Charge. |
| 78 | Supply and fixing of switch piano type 15 Amp, 230 Volt, flush button single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 79 | Supply and fixing of Socket outlet 2 in 1, 3 pin, 5 and 15amp flush type single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 80 | Supply and fix Modular switch 1 way 6A, 1 module type, 230 volts, ISI marked complete. |
| 81 | Supply and fix Socket, 6A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and as directed. |
| 82 | Supply and fix Socket 6A/16A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and as directed. |
| 83 | Supply and fix Modular switch 1 way 16A, 1 module, multipurpose flush type, ISI marked complete all as specified and as directed. |
| 84 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 3 module ISI marked complete all as specified and as directed. |
| 85 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 4 module ISI marked complete all as specified and as directed. |
| 86 | Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 6 module ISI marked complete all as specified and as directed. |
| 87 | M&L Ceiling rose, 3 terminal with ISI mark all as specified and directed by Engr-In-Charge. |
| 88 | Material and labour for lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. Make : Anchor/leader/havells |
| 89 | Supply &Fixing of Buzzer ,Ding Dong AC 230 Volts Singlr Pole complete all as specified and directed by Engineer -in-Charge, |
| 90 | S &F of Bell Push,Flush Type 5 Amp one way complete all as specified and directed by Engineer -in-Charge, |
| 91 | Supply and fix LED 10W Batten white 2 ft (Approx) length ultra slim square profile with extruded polycabonate, enviromenental friendly, energy efficient , connected with 23/.0076 twin core PVC flexible cable complete all as specified and directed. Make- Havells / Philips / Crompton |
| 92 | Supply and fixing recessed mounting 36 W 3000K 2x2 panel luminaire with high performance LEDs suitable for mounting with Grid ceiling Slim square incl driver complete fitting , all as specified and directed by Engr-in-Charge. Make: Crompton / Havells / Wipro |
| 93 | Supply and fix in replacement LED Batten 20W , 4 ft (Approx) length ultra slim square profile with extruded polycabonate, enviromenental friendly, energy efficient , connected with 23/.0076 twin core PVC flexible cable complete all as specified and directed. Make- Havells / Philips / Crompton |
| 94 | Supply and fixing 9 watts LED backup lamp of 4 hours backup, with auto switch on mechanism in case of power failure, works as regular 9w lamp in normal mode and a 4w lamp in backup mode all as specified and directed by Engg-in-Charge. Make: Havells |
| 95 | Supply & Fixing bulk head light with 10 W LED Lamp complete. Make Crompton Cat No LBHP-10-CDL or equivalent in Philips/wipro/Havells |
| 96 | Supply and fixing of sheet metal enclosure double door for DBs single pole and neutral for 12 way 240 volt complete all as specified and directed by Engineer-in-Charge |
| 97 | Supply and fixing amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. (i) SP 6 to 32 Amp |
| 98 | Supply and fixing amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. (ii) SPN 32 to 63 AMP |
| 99 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep heavy duty with, blades, and frame and louvers all as specified and directed by Engr-in-Charge |
| 100 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated 16 sqmm two core aluminium solid conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular all as specified and directed. |
| 101 | Supply and fixing House service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Med. Grade), with two nos of suitable size of clamp,nuts, bolts and wahers etc fixed to GI sheet roof complete all as specified and directed. |
| 102 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level with top edge of the plate not less than 1.5 mtr below the normal ground level connected to the galvanised earth wire 4 mm dia by means of bolts, nuts hook nuts and washers of galvanization of steel all as shown in electrical plate no 3 connected to earthing testing point all as specified or indicated including testing on completions. |
| 103 | Supply and fix electric water heater, storage type steel body and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| 104 | Schedule of Credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender