| 1 | Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and as directed |
| 2 | Excavating in trenches in soft/loose soil, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed. |
| 3 | Returning, filling in including spreading, levelling, watering & well ramming in layers n.exc 25cm of hard/dense soil complete all as specified and as directed. |
| 4 | Removing excavated material /soill to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 5 | M&L for PCC (1:4:8), type D2 using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 6 | M&L for RCC (nominal mix) using cement concrete 1:2:4 Mix , Type B1 (using 20 mm graded crushed stone aggregate) as in foundations, including raft, footings , plinth beams, bases for columns etc complete all as specified and as directed. |
| 7 | M&L RCC (Nominal mix) using cement concrete 1:2:4 Mix, Type B1 (using 20mm graded crushed stone aggregates ) as in columns, pillars etc complete all as specified and as directed. |
| 8 | M&L RCC (Nominal mix) 1:2:4 Mix, Type B1, (using 20mm graded crushed stone aggregates ) as in beam, lintel band over 1.50m clear span complete all as specified and directed. |
| 9 | M&L for formwork to sides of concrete foundations,footings, bases of columns, plinth beams and similar work with fair finish surfaces of concrete flat complete all as specified and as directed. |
| 10 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions with fair finish surfaces of concrete, Square, rectangular or polygonal in shape complete all as specified and as directed. |
| 11 | M&L for formwork to sides and soffits of floor or roof beam , lintels , cantilevers , shelves including supports , overhangs etc. also splays between floors and beams etc. of with fair finish surfaces of concrete flat complete all as specified and as directed. |
| 12 | M&L for Mild steel TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.Note: Weight of TMT bar shall not be considered for payment. |
| 13 | S&F deformed or twisted bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than .9mm dia complete all as specified and as directed. |
| 14 | M&L for moorum/ red bajri filling in floors or pavings, laid in layers not exc 15 CM thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 15 | S&F Steel work in tublar trusses using round/ square/ rectangular shape pipes as approved by the GE including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade ST-240 complete all as specified and as directed. |
| 16 | M&L for Pre cast RCC 1:2:4 Mix, type B1 (using 20 mm graded crushed stone aggregates) as in cover slab for soakage well / manhole and similar works supported on walls set in cement mortar 1:6 complete all as specified and directed.Note:- Reinforcement steel shall be measured & paid separately. |
| 17 | M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:3:6 Mix, type C-2 (Using 20 mm graded crushed stone aggregate) for 150mm bore pipes complete all as specified and directed. |
| 18 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 19 | Material and Labour for providing cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in benching of man holes including forming centre line channel half round or 1/4 section including necessary form work, weathering slightly rounded or chamfered angles and throating, complete all as specified and as directed |
| 20 | M&L for 150 mm PVC (SWR) pipes single socketed in any length with rubber ring joints , laid in trenches complete all as specified and as directed. |
| 21 | S&F GI frame work for snap grid false ceiling comprising of Gl perimeter channnel 0.55 mm thick with Aluminium main T- flange of 25 mm and web of 30 mm fixed to surrounding wall angle with flange and web 25 mm each , Cross T with flange 25 mm and web 25 mm fixed to main T, Main T is suspended from soffit @ 1200 mm c/c using Gi wire of 4mm thickness Aluminium frame will be 60 x 60 cm to recieve ceiling board complete all as specified and as directed . |
| 22 | M&L for 4mm thick non asbestos fiber cement building E boards 600x600 mm prepainted fibre boards ceiling designer/decorative type with different designs as approved by the Engr-in-charge fixed or laid in ceiling timber /GI/ aluminium frame work in ceiling flat or sloping complete all as per manufacturer instruction complete all as specified and as directed. |
| 23 | S&F 2nd class SW boarding 20mm thick fixed with nails as in eaves board planed one side with butt joint including dismantling boarding of any description complete all as specified and as directed. |
| 24 | S&F powder coated (min powder coating 50 micron) anodised aluminium frame for doors, windows , ventilators plain or sliding type with one or more rebates including joining cleat for fixing etc complete all as specified and as directed |
| 25 | S&F powder coated (powder coating min 50 micron) two or three track window and ventilator shutters sliding type without sash , aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150 mm long(1 no) hinges type B-21 100 mm long (2 no) suitable handle (1 no ) complete all as specified and as directed. |
| 26 | S&F 4.80 mm thick frosted sheet glass quality and glazing fixed to aluminium frame not exc 0.50 sqm complete all as specified and as directed. |
| 27 | S&F solid PVC door frame of size 50 mmx 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube as per specifiecation complete all as specified and directed. |
| 28 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) considering of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rails, lock rail & bottom rails on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed togeather with solvent cement, fixing in the frame at site as per specification & drawing. |
| 29 | S&F 100mm stainless steel butt hinges with mild steel hinge pin complete all as specified and directed. |
| 30 | S&F 150 mm aluminium anodised barrel tower bolts and fixed complete all as specified and directed. |
| 31 | S&F Extruded Aluminium, anodised, handles of size 150mm complete all as specified and directed. |
| 32 | S&F 300mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 33 | M & L for Pre-cast cement concrete block masonry using cement concrete, 1:3:6 Mix, type C1 ( using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6 , complete all as specified and directed. |
| 34 | M&L for 25mm thick PCC 1:2:4 type B-0 (12.5 mm graded aggregate) as in levelling coarse of tile flooring etc complete all as specified and as directed. |
| 35 | M&L Glazed ceramic colour tiles of size 450 x 300 x 7mm thick (premium/special quality) as in vertical surfaces wall such as dado/ skirting etc. set and jointed with neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar 1:4 complete all as specified and directed. |
| 36 | M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed. |
| 37 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed. |
| 38 | S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed. |
| 39 | M&L for 10mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and as directed. |
| 40 | M&L for rendering 10 mm thick on concrete surface in cement mortar (1:6) as backing coat and 5 mm th in CM 1:4 using finishing the surface even and smooth without using extra cement, including mixing only liquid water proofing compound as per manufacturer instruction complete all as specified and as directed on External surface.Note:- WPC shall be measured & Paid separately |
| 41 | Supply only for water proofing compound (Powder) complete all as specified and directed. |
| 42 | M&L for providing Hard core of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 43 | M & L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base to floor finished even and smooth without using extra cement complete all as specified and as directed. |
| 44 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded agg) as in plinth protection/path incl finishing even & smooth with using extra cement in, complete all as specified and directed. |
| 45 | M & L for preparation of new plastered/concrete surfaces of walls, and applying 1 mm thick of Birla/JK white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified and directed. |
| 46 | S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 47 | S&F stainless steel grating 100 mm dia complete all as specified and as directed. |
| 48 | S&F in repair brass chromium plated tubular towel rail 600mm long between the flanges and 20mm dia complete all as specified and directed. |
| 49 | S&F soap dish holder complete all as specified and directed. ( Model No. Jaquar Cat Part No:- AKP-35731P or equivalent in Marc/Hindware/Parryware). |
| 50 | S&F corner glass shelf with bracket complete all as specified and directed. (Model No. Jaquar Cat Part No:- ACN-1173 or equivalent in Marc/Parryware/Prayag |
| 51 | Supply and fixing 15mm dia Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed (Centre hole basin mixture chromium plated) complete all as specified and as directed. |
| 52 | S&F Vitreous China Wash Hand Basin of size 550 x 400 mm, white with pedestal including cutting or pinning in ends of brackets or erecting stand, waste coupling and 32 mm dia waste pipe complete all as specified . |
| 53 | S&F Vitreous china squatting pan of pattern Orissa Pattern of size 580x 440 mm white with PVC ‘P’ or ‘S’ trap , front or back inlet but excluding flushing cistern and flush pipe including placing in position in floor and embedded in cushion of PCC type E2 ( 1:5:10, using 40 mm graded stone aggregates), and finishing the top surfaces to match with the existing flooring as in repairs (bore 110 mm) complete all as specified and directed. |
| 54 | S&F 75mm dia of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 55 | S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and directed. |
| 56 | S&F in repair PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and directed. |
| 57 | S&F in repairs PVC (SWR) bend of 110mm bore complete all as specified and directed. |
| 58 | S&F in repairs PVC (SWR) bend of 75mm bore complete all as specified and directed. |
| 59 | S&F for PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 60 | Supply and fix 15 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and directed. |
| 61 | Supply and fix 20 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and directed. |
| 62 | S&F 15mm dia stop valves, fancy type, chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 63 | S&F vitreous china urinal, half stall type, white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed. |
| 64 | S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 65 | M&L for preparation of new steel surface exc 10cm width or girth and applying of two coat of synthetic enamel paint over a one coat of red oxide primer complete all as specified and directed. |
| 66 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 67 | M&L for preparation of new plastered external surface of wall and applying two coats of weather proof paint (Exterior grade) over a coat of alkali resistant primercomplete all as specified and directed. |
| 68 | M&L for pre construction anti termite treatment by treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed |
| 69 | M&L for pre construction anti termite treatment by treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed |
| 70 | M&L for reinforced cement concrete 1:2:4 Mix, (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and the like as in pavement slab etc. complete all as specified and directed. |
| 71 | Material & Labour for formwork to soffits of suspended slabs such as roof slab not exceeding 200mm thick (Horizontal or sloping) fair finished surfaces of concrete flat complete all as specified and as directed. |
| 72 | Supply and fixing 2nd class HW plain solid straight chowkhats/frame wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 73 | S&F 30 mm thick Flush door shutters solid core construction with block board core and plywood face pannels, commercial type on both sides complete all as specified and directed. |
| 74 | S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 75 | M&L for precast cement concrete block masonry using cement concrete 1:3:6 Mix, type C1 (Using 20 mm graded crushed stone aggregate) with solid blocks n exc 10 cm in width and settings in CM 1:4 complete all as specified and directed. |
| 76 | M&L for 40 mm thick PCC 1:2:4 type B1 (using 20mm graded agg) as in floor incl finishing even & smooth using extra cement complete all as specified and as directed. |
| 77 | M&L for 5 mm thick rendering in CM 1:3 on ceiling surface, finished even and smooth without using extra cement complete all as specified and as directed. |
| 78 | Taking down chowkhats or frame with shutter without taking off shutter from the frame area exc 1.50 sqm but not exc 4 sqm each & removing from site complete all as specified and directed. |
| 79 | Demolition for Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 80 | M&L for plastering 15mm thick in CM 1:6 on fair faces of lathing walls to be finished even and smooth (without using extra cement) complete all as specified and directed. |
| 81 | S&F 12mm thick Plywood, grade BWR, type BB, No of ply 07, fixed with screws to timber frame work complete all as specified and directed. |
| 82 | S&F 6 mm thick Plywood, grade BWR, type BB, No of ply 07, fixed with screws to timber frame work complete all as specified and directed. |
| 83 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 84 | Dismantling of timber scantling in fillets, rails, posts, rafters, purlins etc under 40 sqcm in section in any position complete all as specified and directed. |
| 85 | Dismantling boarding any description fixed in any position with nails complete all as specified and as directed |
| 86 | S&F 18/19 mm thick Block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work complete all as specified and directed |
| 87 | S&F 0.90 mm thick pvc decorative laminates type 1 of surface finish color and pattern as approved fixed with approved adhesive as per manufactures instruction complete all as specified and directed. |
| 88 | M&L for preparation of newly plastered surfaces of wall and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified and directed. |
| 89 | S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, Width of flaps 30mm (when open) complete all as specified and directed. |
| 90 | S&F extruded brass bow handles of size 125 mm, fabricated type, polished complete all as specified and directed. |
| 91 | S&F extruded brass bow handles of size 150 mm, fabricated type, polished complete all as specified and directed. |
| 92 | S&F magnetic catches, brass body and striking plate including letting in and fixed complete all as specified and directed. |
| 93 | Demolition of reinforced (reinforcement cut as required to facilitate demolition) Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed. |
| 94 | M&L for providing RCC (Nominal Mix), 1:2:4 Mix, type B1 (Using 20 mm graded crushed stone aggregate) as in dome, vaults, shell roof etc complete all as specified and directed. |
| 95 | M & L form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specified and as directed. |
| 96 | S&F in repairs kitchen sink with drainage board overall size 915x460 mm & bowl size 410mmx360mmx160 mm, made of stainless steel 1mm thick with plug washers and wastes including bedding in CM to dwarf wall or including fixing cantilever brackets and connecting union to pipe complete all as specified and directed. |
| 97 | S&F 25mm dia harrison rails (curtain rails), anodised aluminium alloy with fixing brackets, stops, rollers etc. complete all as specified and directed. |
| 98 | M&L for 18/20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to matchwith shade of granite complete including making hole for gas pipe through precast RCC slab & granite stone etc including rounding of ecposed edges complete all as specified and directed. NOTE FOR ALL ITEMSIn case in BOQ any item found repeated and contractor quotes different rate for the same, the rate quoted on lesser side shall only be applicable for payment and no claim whatsoever on this account shall be entertained by the Department. Please Enable Macros to View BoQ information |